Machine Features:
- Made with the most advanced Germany technologies and process. Double deck structure with double or single tunnel. For beverage (beer) pasteurizing and warming
- Central heating with hot water buffer tank.Save steam and water compared to traditional ones
- Advance German PU control system.Control accuracy high and energy consumption low
- Optimal arrange of temperature zones(10-12 zones). Sufficient heat exchange, tiny temperature variance between zones, few broken bottle, stable running
- Double deck spraying with plastic clip-on nozzles of German design. Wide and even spraying. On-line clip-on flushing nozzles to avoid jam, which can be easily detachable
- Stainless Steel for tunnels, main belt and heat exchanger
- Open frame structure with maintenance doors with inspection windows on both sides
- Cleaning manhole for each water tank
- Auto on-line filtration system
- One motor for every belt with overload protection. frequency converters for motors provide more protection and easy adjustion to the machine
- Clean water rinsing system on top of the outfeed conveyor. Nozzles can be installed to rinse bottle caps if required
- I/O control cabinet communicate with PLC via ProfiBUS. Easy maintenance
Model & Size | PISSC42-143 Energy- efficient Pasteurizer | PIISC52-180 Energy- efficient Pasteurizer | PIISC52-233 Energy- efficient Pasteurizer | PIISC52-285 Energy- efficient Pasteurizer | BPII52-225 Energy- efficient Pasteurizer |
Nominal Capacity 640ml bottle(Φ75mm) | 24000 | 40000 | 40000 | 50000 | 50000 |
Total treatment area | 119.7m2 | 189m2 | 244m2 | 299m2 | 236m2 |
Total treatment time | 62.2min | 51.1min | 66.1min | 68min | |
Pasteurizer time | 9.8min | 8.5min | 6.6min | 10min | |
Layers | 2 | 2 | 2 | 2 | 2 |
Warm zones | 10 | 10 | 12 | 12 | 10 |
Heat zones | 3 | 3 | 4 | 4 | 3 |
Pasteurize zones | 4 | 4 | 4 | 4 | 4 |
Pateurizer temperature | 61.5 | 61.5 | 61.5 | 62 | 61.5 |
Bottle infeed temperature | 7 | 5 | 10 | 5 | 7 |
Bottle discharge temperature under balance state | 35 | 35 | 30 | ≤30 | 35 |
Max. clean water temperature | 30 | 30 | 30 | 28 | 30 |
Min. clean water temperature | 12 | 12 | 12 | 5 | 12 |
Total pasteurize unit | 20PU | 20PU | 10PU | 10PU | 20PU |
Heat consumption | 5bar | 5bar | 5bar | 5bar | 5bar |
Max. heat consumption during power on | 2000kg/h | 3700kg/h | 3361kg/h | 4280kg/h | 4220kg/h |
Heat consumption under balance state | 930kg/h | 2000kg/h | 1400kg/h | 1905kg/h | 2254kg/h |
Compressed air consumption | 6bar | 6bar | 6bar | 0.5Mpa | 6bar |
Consumption | 6bar | 2.5m3n/h | 2.5m3n/h | 2.5m3n/h | 2.5m3n/h |
Water pressure during production | 2-5bar | 2-5bar | 2-5bar | 2-5bar | 2-5bar |
Consumption under continuous operation | 1~2m3/h | 1~2m3/h | 1~2m3/h | 1~2m3/h | 1~2m3/h |
Max. water volume | 8.8m3 | 12.9m3 | 14.6 m3 | 18 m3 | 14 m3 |
Total installed power | 81.95kW | 104.45 kW | 129.95 kW | 160.35 kW | 125.45 kW |
Overal dimension (L*W*H) (without operation flat and pipeline) | 15650×4620×3269mm | 21500×7300×3269mm | 26400×7300×3269mm | 32110×7300×3269mm | 26110×7300×3269mm |
Net weight | 31T | 54T | 60T | 68T | 55T |
Operation weight | 70T | 140T | 155T | 175T | 150T |