| product brand name | SIRIUS | |
| product designation | safety relays | |
| design of the product | for EMERGENCY-STOP and safety doors | |
| product type designation | 3TK28 | |
| Product Function | ||
| product function | ||
| ¡ñ automatic start | Yes | |
| ¡ñ light barrier monitoring | No | |
| ¡ñ standstill monitoring | No | |
| ¡ñ protective door monitoring | Yes | |
| ¡ñ magnetically operated switch monitoring NC-NO | No | |
| ¡ñ magnetically operated switch monitoring NC-NC | No | |
| ¡ñ rotation speed monitoring | No | |
| ¡ñ laser scanner monitoring | No | |
| ¡ñ light array monitoring | No | |
| ¡ñ EMERGENCY OFF function | Yes | |
| ¡ñ monitored start-up | Yes | |
| ¡ñ pressure-sensitive mat monitoring | Yes | |
| suitability for interaction press control | No | |
| suitability for use | ||
| ¡ñ monitoring of floating sensors | Yes | |
| ¡ñ monitoring of non-floating sensors | No | |
| ¡ñ position switch monitoring | Yes | |
| ¡ñ EMERGENCY-OFF circuit monitoring | Yes | |
| ¡ñ valve monitoring | No | |
| ¡ñ opto-electronic protection device monitoring | No | |
| ¡ñ tactile sensor monitoring | No | |
| ¡ñ magnetically operated switch monitoring | No | |
| ¡ñ proximity switch monitoring | No | |
| ¡ñ safety switch | Yes | |
| ¡ñ safety-related circuits | Yes | |
| General technical data | ||
| certificate of suitability UL approval | Yes | |
| product feature cross-circuit-proof | Yes | |
| insulation voltage rated value | 300 V | |
| surge voltage resistance rated value | 4 000 V | |
| protection class IP | ||
| ¡ñ of the enclosure | IP20 | |
| ¡ñ of the terminal | IP20 | |
| shock resistance | 8g / 10 ms | |
| vibration resistance according to IEC 60068-2-6 | 5 ... 500 Hz: 0,075 mm | |
| operating frequency maximum | 1 000 1/h | |
| mechanical service life (operating cycles) typical | 10 000 000 | |
| electrical endurance (operating cycles) typical | 100 000 | |
| thermal current of the switching element with contacts maximum | 6 A | |
| Substance Prohibitance (Date) | 05/01/2012 | |
| SVHC substance name | Lead monoxide (lead oxide) - 1317-36-8 | |
| Weight | 0.404 kg | |
| Ambient conditions | ||
| installation altitude at height above sea level maximum | 2 000 m | |
| ambient temperature | ||
| ¡ñ during operation | -25 ... +60 °C | |
| ¡ñ during storage | -40 ... +80 °C | |
| relative humidity during operation | 10 ... 95 % | |
| air pressure according to SN 31205 | 90 ... 106 kPa | |
| Electromagnetic compatibility | ||
| installation environment regarding EMC | This product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case. | |
| EMC emitted interference | EN 60947-5-1 | |
| Safety related data | ||
| stop category according to IEC 60204-1 | 0 | |
| IEC 62061 | ||
| SIL Claim Limit (subsystem) according to EN 62061 | 3 | |
| PFHD with high demand rate according to IEC 62061 | 1.5E-9 1/h | |
| ISO 13849 | ||
| category according to EN ISO 13849-1 | 4 | |
| IEC 61508 | ||
| Safety Integrity Level (SIL) | ||
| ¡ñ according to IEC 61508 | 3 | |
| safety device type according to IEC 61508-2 | Type A | |
| Average probability of failure on demand (PFDavg) with low demand rate acc. to IEC 61508 | 1.3E-6 1/y | |
| hardware fault tolerance according to IEC 61508 | 1 | |
| T1 value for proof test interval or service life according to IEC 61508 | 20 a | |
| Electrical Safety | ||
| touch protection against electrical shock | finger-safe | |
| Short-circuit protection | ||
| design of the fuse link for short-circuit protection of the NO contacts of the relay outputs required | gL/gG: 6 A, or quick: 10 A | |
| Inputs | ||
| design of input | ||
| ¡ñ cascading input/functional switching | No | |
| ¡ñ feedback input | Yes | |
| ¡ñ start input | Yes | |
| number of sensor inputs | ||
| ¡ñ 1-channel or 2-channel | 1 | |
| Outputs | ||
| number of outputs as contact-affected switching element | ||
| ¡ñ as NC contact | ||
| — for signaling function instantaneous contact | 2 | |
| ¡ñ as NO contact | ||
| — safety-related instantaneous contact | 3 | |
| — safety-related delayed switching | 0 | |
| number of outputs as contact-less semiconductor switching element | ||
| ¡ñ for signaling function | ||
| — delayed switching | 0 | |
| — instantaneous contact | 0 | |
| ¡ñ safety-related | ||
| — delayed switching | 0 | |
| — instantaneous contact | 0 | |
| switching capacity current of the NO contacts of the relay outputs at DC-13 | ||
| ¡ñ at 24 V | 6 A | |
| ¡ñ at 115 V | 0.2 A | |
| ¡ñ at 230 V | 0.1 A | |
| switching capacity current of the NO contacts of the relay outputs at AC-15 | ||
| ¡ñ at 115 V | 6 A | |
| ¡ñ at 230 V | 6 A | |
| switching capacity current of the NC contacts of the relay outputs at DC-13 | ||
| ¡ñ at 24 V | 6 A | |
| ¡ñ at 115 V | 0.2 A | |
| ¡ñ at 230 V | 0.1 A | |
| switching capacity current of the NC contacts of the relay outputs at AC-15 | ||
| ¡ñ at 115 V | 6 A | |
| ¡ñ at 230 V | 6 A | |
| wire length between sensor and electronics evaluation device with Cu 1.5 mm² and 150 nF/km maximum | 1 000 m | |
| Times | ||
| make time with automatic start | ||
| ¡ñ at AC maximum | 150 ms | |
| make time with monitored start | ||
| ¡ñ maximum | 25 ms | |
| backslide delay time in the event of power failure | ||
| ¡ñ maximum | 350 ms | |
| recovery time after opening of the safety circuits typical | 200 ms | |
| recovery time after power failure typical | 0.5 s | |
| pulse duration | ||
| ¡ñ of the sensor input minimum | 25 ms | |
| ¡ñ of the ON pushbutton input minimum | 25 ms | |
| Control circuit/ Control | ||
| type of voltage of the control supply voltage | DC | |
| control supply voltage 1 at DC rated value | 24 V | |
| operating range factor control supply voltage rated value of magnet coil at DC | ||
| ¡ñ initial value | 0.85 | |
| ¡ñ full-scale value | 1.1 | |
| operating range factor control supply voltage rated value of magnet coil at AC | ||
| ¡ñ at 50 Hz | 0.85 ... 1.1 | |
| ¡ñ at 60 Hz | 0.85 ... 1.1 | |
| Installation/ mounting/ dimensions | ||
| mounting position | any | |
| fastening method | screw and snap-on mounting | |
| height | 138.5 mm | |
| width | 44.8 mm | |
| depth | 120 mm | |
| Connections/ Terminals | ||
| type of electrical connection | screw terminal | |
| type of connectable conductor cross-sections | ||
| ¡ñ solid | 1x (0.5 ... 4.0mm²), 2x (0.5 ... 2.5 mm²) | |
| ¡ñ finely stranded with core end processing | 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) | |
| ¡ñ for AWG cables solid | 2x (20 ... 14) | |
| ¡ñ for AWG cables stranded | 2x (20 ... 14) | |
| connectable conductor cross-section | ||
| ¡ñ solid | 0.5 ... 4 mm² | |
| ¡ñ finely stranded with core end processing | 0.5 ... 2.5 mm² | |
| AWG number as coded connectable conductor cross section | ||
| ¡ñ solid | 20 ... 14 | |
| ¡ñ stranded | 20 ... 14 | |
| DC resistance of the cable maximum | 30 !& | |
| type of electrical connection plug-in socket | Yes | |





MY 4510
BR 4217
US 3081
CN 1549
SG 662
AR 427
GB 371
MX 319