product brand name |
SIRIUS |
product designation |
safety relays |
design of the product |
for EMERGENCY-STOP and safety doors |
product type designation |
3TK28 |
Product Function |
product function |
|
● automatic start |
Yes |
● light barrier monitoring |
No |
● standstill monitoring |
No |
● protective door monitoring |
Yes |
● magnetically operated switch monitoring NC-NO |
No |
● magnetically operated switch monitoring NC-NC |
No |
● rotation speed monitoring |
No |
● laser scanner monitoring |
No |
● light array monitoring |
No |
● EMERGENCY OFF function |
Yes |
● monitored start-up |
Yes |
● pressure-sensitive mat monitoring |
Yes |
suitability for interaction press control |
No |
suitability for use |
|
● monitoring of floating sensors |
Yes |
● monitoring of non-floating sensors |
No |
● position switch monitoring |
Yes |
● EMERGENCY-OFF circuit monitoring |
Yes |
● valve monitoring |
No |
● opto-electronic protection device monitoring |
No |
● tactile sensor monitoring |
No |
● magnetically operated switch monitoring |
No |
● proximity switch monitoring |
No |
● safety switch |
Yes |
● safety-related circuits |
Yes |
General technical data |
certificate of suitability UL approval |
Yes |
product feature cross-circuit-proof |
Yes |
insulation voltage rated value |
300 V |
surge voltage resistance rated value |
4 000 V |
protection class IP |
|
● of the enclosure |
IP20 |
● of the terminal |
IP20 |
shock resistance |
8g / 10 ms |
vibration resistance according to IEC 60068-2-6 |
5 ... 500 Hz: 0,075 mm |
operating frequency maximum |
1 000 1/h |
mechanical service life (operating cycles) typical |
10 000 000 |
electrical endurance (operating cycles) typical |
100 000 |
thermal current of the switching element with contacts maximum |
6 A |
Substance Prohibitance (Date) |
05/01/2012 |
SVHC substance name |
Lead monoxide (lead oxide) - 1317-36-8 |
Weight |
0.404 kg |
Ambient conditions |
installation altitude at height above sea level maximum |
2 000 m |
ambient temperature |
|
● during operation |
-25 ... +60 °C |
● during storage |
-40 ... +80 °C |
relative humidity during operation |
10 ... 95 % |
air pressure according to SN 31205 |
90 ... 106 kPa |
Electromagnetic compatibility |
installation environment regarding EMC |
This product is suitable for Class A environments only. In household environments, this device can cause unwanted radio interference. The user is required to implement appropriate measures in this case. |
EMC emitted interference |
EN 60947-5-1 |
Safety related data |
stop category according to IEC 60204-1 |
0 |
IEC 62061 |
SIL Claim Limit (subsystem) according to EN 62061 |
3 |
PFHD with high demand rate according to IEC 62061 |
1.5E-9 1/h |
ISO 13849 |
category according to EN ISO 13849-1 |
4 |
IEC 61508 |
Safety Integrity Level (SIL) |
|
● according to IEC 61508 |
3 |
safety device type according to IEC 61508-2 |
Type A |
Average probability of failure on demand (PFDavg) with low demand rate acc. to IEC 61508 |
1.3E-6 1/y |
hardware fault tolerance according to IEC 61508 |
1 |
T1 value for proof test interval or service life according to IEC 61508 |
20 a |
Electrical Safety |
touch protection against electrical shock |
finger-safe |
Short-circuit protection |
design of the fuse link for short-circuit protection of the NO contacts of the relay outputs required |
gL/gG: 6 A, or quick: 10 A |
Inputs |
design of input |
|
● cascading input/functional switching |
No |
● feedback input |
Yes |
● start input |
Yes |
number of sensor inputs |
|
● 1-channel or 2-channel |
1 |
Outputs |
number of outputs as contact-affected switching element |
|
● as NC contact |
|
— for signaling function instantaneous contact |
2 |
● as NO contact |
|
— safety-related instantaneous contact |
3 |
— safety-related delayed switching |
0 |
number of outputs as contact-less semiconductor switching element |
|
● for signaling function |
|
— delayed switching |
0 |
— instantaneous contact |
0 |
● safety-related |
|
— delayed switching |
0 |
— instantaneous contact |
0 |
switching capacity current of the NO contacts of the relay outputs at DC-13 |
|
● at 24 V |
6 A |
● at 115 V |
0.2 A |
● at 230 V |
0.1 A |
switching capacity current of the NO contacts of the relay outputs at AC-15 |
|
● at 115 V |
6 A |
● at 230 V |
6 A |
switching capacity current of the NC contacts of the relay outputs at DC-13 |
|
● at 24 V |
6 A |
● at 115 V |
0.2 A |
● at 230 V |
0.1 A |
switching capacity current of the NC contacts of the relay outputs at AC-15 |
|
● at 115 V |
6 A |
● at 230 V |
6 A |
wire length between sensor and electronics evaluation device with Cu 1.5 mm² and 150 nF/km maximum |
1 000 m |
Times |
make time with automatic start |
|
● at AC maximum |
150 ms |
make time with monitored start |
|
● maximum |
25 ms |
backslide delay time in the event of power failure |
|
● maximum |
350 ms |
recovery time after opening of the safety circuits typical |
200 ms |
recovery time after power failure typical |
0.5 s |
pulse duration |
|
● of the sensor input minimum |
25 ms |
● of the ON pushbutton input minimum |
25 ms |
Control circuit/ Control |
type of voltage of the control supply voltage |
DC |
control supply voltage 1 at DC rated value |
24 V |
operating range factor control supply voltage rated value of magnet coil at DC |
|
● initial value |
0.85 |
● full-scale value |
1.1 |
operating range factor control supply voltage rated value of magnet coil at AC |
|
● at 50 Hz |
0.85 ... 1.1 |
● at 60 Hz |
0.85 ... 1.1 |
Installation/ mounting/ dimensions |
mounting position |
any |
fastening method |
screw and snap-on mounting |
height |
138.5 mm |
width |
44.8 mm |
depth |
120 mm |
Connections/ Terminals |
type of electrical connection |
screw terminal |
type of connectable conductor cross-sections |
|
● solid |
1x (0.5 ... 4.0mm²), 2x (0.5 ... 2.5 mm²) |
● finely stranded with core end processing |
1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) |
● for AWG cables solid |
2x (20 ... 14) |
● for AWG cables stranded |
2x (20 ... 14) |
connectable conductor cross-section |
|
● solid |
0.5 ... 4 mm² |
● finely stranded with core end processing |
0.5 ... 2.5 mm² |
AWG number as coded connectable conductor cross section |
|
● solid |
20 ... 14 |
● stranded |
20 ... 14 |
DC resistance of the cable maximum |
30 !& |
type of electrical connection plug-in socket |
Yes |