Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
EKG M & E SDN BHD
EKG M & E SDN BHD 201201033712 (1018200-D)
Business
Hours
Monday - Friday 9:00 AM - 5:30 PM
Saturday 9:00 AM - 1:00 PM
Sunday Closed
We′re closed on Public Holiday
Open Closed
SSM
VISITORS

25-Mar-2026

Office Fresh Air System | High-Performance Ventilation

A modern office fresh air system is the "respiratory system" of a building. In Malaysia’s tropical climate, this system faces a dual challenge: providing enough oxygen to keep occupants alert while stripping out extreme humidity and urban pollutants. At EKG M&E, we move beyond simple "air intake" to engineered Dedicated Outdoor Air Systems (DOAS) that ensure compliance with the 2026 DOSH Industry Code of Practice on IAQ.

By delivering a consistent flow of 10 l/s per person, we eliminate the "3 PM slump" caused by Carbon Dioxide (CO2) buildup and protect the building from mold and structural dampness.


1. Controlled Fresh Air Intake & Dehumidification

In Kuala Lumpur, simply bringing in "fresh" air means bringing in 90% humidity. Our systems are designed to treat this air before it enters the office floor:

  • Pre-Cooling Coils: We drop the temperature of incoming air to condense out moisture. This prevents "Latent Heat" from overloading your main office air conditioning.

  • Positive Building Pressure: We calibrate the system to maintain a slight positive pressure (+5 to +12 Pa). This creates an invisible shield that pushes air out of door gaps, preventing hot, humid, and unfiltered air from leaking into the office.

  • Multi-Stage Filtration: Every intake is equipped with MERV 13 or higher filters to strip out PM2.5 haze and vehicle exhaust from the city streets.


2. Demand-Controlled Ventilation (DCV)

Energy efficiency is a major pillar of the Energy Efficiency and Conservation Act (EECA). We ensure you aren't paying to ventilate empty rooms:

  • CO2 Sensors: We install high-precision sensors in boardrooms and open-plan areas. When occupancy drops, the system automatically scales back.

  • VFD Modulation: We utilize Variable Frequency Drives (VFDs) to control the intake fans. According to the Cube Law of Power, reducing fan speed by just 20% via the VFD can cut the fan's electricity consumption by nearly 50%.

  • Soft-Start Technology: VFDs eliminate the high-current "surge" when large ventilation fans start up, protecting your building's electrical switchgear.


3. Heat & Energy Recovery (ERV/HRV)

To reduce the cost of cooling hot Malaysian air, we utilize Energy Recovery Ventilation (ERV) to "recycle" the cool energy from the air being exhausted:

  • Enthalpy Exchange: An enthalpy wheel transfers both "coolth" and dryness from the outgoing office air to the incoming fresh air.

  • Thermal Efficiency: This process can reduce the total cooling load on your chillers by 20% to 30%, making it a high-scoring strategy for GBI (Green Building Index) or LEED certifications.


4. Mechanical Health & Vibration Diagnostics

Large fresh air fans often run 24/7. To prevent unexpected noise or mechanical failure, we employ Fast Fourier Transform (FFT) Analysis:

  • Vibration Fingerprinting: We monitor the "vibration signature" of the fan motors. We can detect bearing wear or belt misalignment months before a breakdown occurs.

  • Resonance Locking: We program the VFD to "skip" frequencies that cause the intake ductwork to vibrate or "drum," ensuring the office remains a quiet environment for focused work.


Why Optimize Your Fresh Air System?

  • Health & Productivity: Proper oxygenation reduces headaches and respiratory irritation among staff.

  • Compliance: Our designs meet the 2026 DOSH mandates for indoor air quality.

  • Asset Longevity: Controlling humidity prevents mold growth on carpets, ceiling tiles, and sensitive IT equipment.

Send your message to EKG M & E SDN BHD
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

EKG M & E SDN BHD 201201033712 (1018200-D)
27-2 & 27-3, Jalan Kuchai Maju, Kuchai Entrepreneur¡¯s Park, Off Jalan Kuchai Lama, 58200 Kuala Lumpur, Malaysia.

Tel:

Email:
Website: https://www.eakon.com.my
Website: https://eakon.newpages.com.my/
Website: https://eakon.onesync.my/

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us