请登录后使用此功能。 您可以使用此功能将商品添加到您的收藏列表。
关闭
您已经添加该商品到您的收藏列表。 查看我的收藏
关闭
从您收藏列表中删除此商品。
关闭
请登录后使用此功能。 您可以使用此功能将公司添加到您的收藏夹列表。
关闭
这家公司已成功添加。 查看我的收藏
关闭
这家公司已从你的收藏夹列表中删除。
关闭
请登录后使用此功能。 您可以使用此功能将公司添加到您的询问车。
关闭
这家公司已被添加到您的询问车。
关闭
这家公司已从询价车中删除。
关闭
该商品已被添加到您的询问车。
关闭
该商品已经从您的询价车中删除。
关闭
商品/公司已达到添加至询价车的数量。
关闭
KCK Sustainability Solutions Sdn Bhd
KCK Sustainability Solutions Sdn Bhd 202401039757 (1585604-V)

Energy Audit Chilled Water System

Energy Audit Chilled Water System

Scope :

  1. Pre-Audit Review and Site Walkthrough

    • Collect system design documents, drawings, load profiles, and operating schedules

    • Conduct a site walkthrough to inspect chillers, pumps, cooling towers, AHUs, and control systems

    • Interview operations and maintenance staff

  2. Data Collection and Instrumentation Setup

    • Install temporary energy meters (power analyzers) on:

      • Chillers (main compressors)

      • Condenser water pumps

      • Chilled water pumps

      • Cooling tower fans

    • Log data for power (kW), voltage, current, and power factor

    • Install flow meters and temperature sensors on chilled and condenser water loops

  3. Real-Time Performance Measurement

    • Record actual cooling load (RT), chilled water flow, inlet/outlet temperatures

    • Measure and log system kW usage during normal, peak, and partial load conditions

    • Monitor equipment cycling, setpoint accuracy, and control sequences

  4. kW/RT Calculation and Benchmarking

    • Compare results against local and international benchmarks (e.g., <0.8 kW/RT for efficient systems)

    • Identify deviations, inefficiencies, and abnormal operation patterns

  5. System Efficiency Analysis

    • Evaluate individual equipment efficiency:

      • Chiller performance (COP, partial-load behavior)

      • Pump and fan energy consumption

      • Cooling tower approach temperature

    • Assess control system logic and automation effectiveness (e.g., BMS, VSD operation, staging)

  6. Improvement Recommendations

    • Identify retrofit opportunities (e.g., VSDs, high-efficiency chillers, control upgrades)

    • Suggest operational improvements (e.g., setpoint tuning, load balancing, better scheduling)

    • Estimate energy savings, payback periods, and potential carbon reduction

  7. Reporting and Presentation

    • Deliver a detailed audit report including:

      • Current kW/RT performance

      • Energy usage breakdown

      • Graphs, charts, and logged data

      • List of proposed improvements with ROI estimates

总办事处

KCK Sustainability Solutions Sdn Bhd 202401039757 (1585604-V)
34, Block C, Pusat Perdagangan Ion Medini 4, Persiaran Medini Sentral 5, Iskandar Puteri, 79600 Johor Bahru, Johor, Malaysia.

电话:

邮件:
网址: https://www.kck-ss.com
网址: https://kck-ss.newpages.com.my/
网址: https://kck-ss.onesync.my/

游览 : 首页 - 分类 - 公司 - 地区 - 标签 - 商品 - 消息与促销 - 工作征聘 - 手机版 - 谷歌 - 搜索引擎优化结果

NEWPAGES

  • US 6970
  • GB 6859
  • AU 6103
  • CA 6020
  • IE 4250
  • NZ 2197
  • BR 747
  • SG 574
人 在线
Seni Jaya Logo
Brochure
Download
Our PackageContact Us