General information |
Product type designation |
CPU 315-2 DP |
HW functional status |
01 |
Firmware version |
V3.3 |
Product function |
¡ñ Isochronous mode |
Yes |
Engineering with |
¡ñ Programming package |
STEP 7 V5.5 + SP1 or higher or STEP 7 V5.2 + SP1 or higher with HSP 218 |
Supply voltage |
Rated value (DC) |
24 V |
permissible range, lower limit (DC) |
19.2 V |
permissible range, upper limit (DC) |
28.8 V |
external protection for power supply lines (recommendation) |
2 A min. |
Mains buffering |
¡ñ Mains/voltage failure stored energy time |
5 ms |
¡ñ Repeat rate, min. |
1 s |
Input current |
Current consumption (rated value) |
850 mA |
Current consumption (in no-load operation), typ. |
150 mA |
Inrush current, typ. |
3.5 A |
I²t |
1 A²·s |
Power loss |
Power loss, typ. |
4.5 W |
Memory |
Work memory |
¡ñ integrated |
256 kbyte |
¡ñ expandable |
No |
Load memory |
¡ñ Plug-in (MMC) |
Yes |
¡ñ Plug-in (MMC), max. |
8 Mbyte |
¡ñ Data management on MMC (after last programming), min. |
10 a |
Backup |
¡ñ present |
Yes; Guaranteed by MMC (maintenance-free) |
¡ñ without battery |
Yes; Program and data |
CPU processing times |
for bit operations, typ. |
0.05 µs |
for word operations, typ. |
0.09 µs |
for fixed point arithmetic, typ. |
0.12 µs |
for floating point arithmetic, typ. |
0.45 µs |
CPU-blocks |
Number of blocks (total) |
1 024; (DBs, FCs, FBs); the maximum number of loadable blocks can be reduced by the MMC used. |
DB |
¡ñ Number, max. |
1 024; Number range: 1 to 16000 |
¡ñ Size, max. |
64 kbyte |
FB |
¡ñ Number, max. |
1 024; Number range: 0 to 7999 |
¡ñ Size, max. |
64 kbyte |
FC |
¡ñ Number, max. |
1 024; Number range: 0 to 7999 |
¡ñ Size, max. |
64 kbyte |
OB |
¡ñ Number, max. |
see instruction list |
¡ñ Size, max. |
64 kbyte |
¡ñ Number of free cycle OBs |
1; OB 1 |
¡ñ Number of time alarm OBs |
1; OB 10 |
¡ñ Number of delay alarm OBs |
2; OB 20, 21 |
¡ñ Number of cyclic interrupt OBs |
4; OB 32, 33, 34, 35 |
¡ñ Number of process alarm OBs |
1; OB 40 |
¡ñ Number of DPV1 alarm OBs |
3; OB 55, 56, 57 |
¡ñ Number of isochronous mode OBs |
1; OB 61 |
¡ñ Number of startup OBs |
1; OB 100 |
¡ñ Number of asynchronous error OBs |
5; OB 80, 82, 85, 86, 87 |
¡ñ Number of synchronous error OBs |
2; OB 121, 122 |
Nesting depth |
¡ñ per priority class |
16 |
¡ñ additional within an error OB |
4 |
Counters, timers and their retentivity |
S7 counter |
¡ñ Number |
256 |
Retentivity |
— adjustable |
Yes |
— preset |
Z 0 to Z 7 |
Counting range |
— lower limit |
0 |
— upper limit |
999 |
IEC counter |
¡ñ present |
Yes |
¡ñ Type |
SFB |
¡ñ Number |
Unlimited (limited only by RAM capacity) |
S7 times |
¡ñ Number |
256 |
Retentivity |
— adjustable |
Yes |
— preset |
No retentivity |
Time range |
— lower limit |
10 ms |
— upper limit |
9 990 s |
IEC timer |
¡ñ present |
Yes |
¡ñ Type |
SFB |
¡ñ Number |
Unlimited (limited only by RAM capacity) |
Data areas and their retentivity |
Retentive data area (incl. timers, counters, flags), max. |
128 kbyte |
Flag |
¡ñ Size, max. |
2 048 byte |
¡ñ Retentivity available |
Yes; MB 0 to MB 2 047 |
¡ñ Retentivity preset |
MB 0 to MB 15 |
¡ñ Number of clock memories |
8; 1 memory byte |
Data blocks |
¡ñ Retentivity adjustable |
Yes; via non-retain property on DB |
¡ñ Retentivity preset |
Yes |
Local data |
¡ñ per priority class, max. |
32 kbyte; Max. 2 KB per block |
Address area |
I/O address area |
¡ñ Inputs |
2 048 byte |
¡ñ Outputs |
2 048 byte |
of which distributed |
— Inputs |
2 048 byte |
— Outputs |
2 048 byte |
Process image |
¡ñ Inputs |
2 048 byte |
¡ñ Outputs |
2 048 byte |
¡ñ Inputs, adjustable |
2 048 byte |
¡ñ Outputs, adjustable |
2 048 byte |
¡ñ Inputs, default |
128 byte |
¡ñ Outputs, default |
128 byte |
Subprocess images |
¡ñ Number of subprocess images, max. |
1 |
Digital channels |
¡ñ Inputs |
16 384 |
— of which central |
1 024 |
¡ñ Outputs |
16 384 |
— of which central |
1 024 |
Analog channels |
¡ñ Inputs |
1 024 |
— of which central |
256 |
¡ñ Outputs |
1 024 |
— of which central |
256 |
Hardware configuration |
Number of expansion units, max. |
3 |
Number of DP masters |
¡ñ integrated |
1 |
¡ñ via CP |
4 |
Number of operable FMs and CPs (recommended) |
¡ñ FM |
8 |
¡ñ CP, PtP |
8 |
¡ñ CP, LAN |
10 |
Rack |
¡ñ Racks, max. |
4 |
¡ñ Modules per rack, max. |
8 |
Time of day |
Clock |
¡ñ Hardware clock (real-time) |
Yes |
¡ñ retentive and synchronizable |
Yes |
¡ñ Backup time |
6 wk; At 40 °C ambient temperature |
¡ñ Deviation per day, max. |
10 s; Typ.: 2 s |
¡ñ Behavior of the clock following POWER-ON |
Clock continues running after POWER OFF |
¡ñ Behavior of the clock following expiry of backup period |
the clock continues at the time of day it had when power was switched off |
Operating hours counter |
¡ñ Number |
1 |
¡ñ Number/Number range |
0 |
¡ñ Range of values |
0 to 2^31 hours (when using SFC 101) |
¡ñ Granularity |
1 h |
¡ñ retentive |
Yes; Must be restarted at each restart |
Clock synchronization |
¡ñ supported |
Yes |
¡ñ to MPI, master |
Yes |
¡ñ on MPI, device |
Yes |
¡ñ to DP, master |
Yes; With DP slave only slave clock |
¡ñ on DP, device |
Yes |
¡ñ in AS, master |
Yes |
¡ñ in AS, device |
No |
Digital inputs |
Number of digital inputs |
0 |
Digital outputs |
Number of digital outputs |
0 |
Analog inputs |
Number of analog inputs |
0 |
Interfaces |
Number of PROFINET interfaces |
0 |
Number of RS 485 interfaces |
2; MPI and PROFIBUS DP |
Number of RS 422 interfaces |
0 |
1. Interface |
Interface type |
Integrated RS 485 interface |
Isolated |
No |
Interface types |
¡ñ RS 485 |
Yes |
¡ñ Output current of the interface, max. |
200 mA |
Protocols |
¡ñ MPI |
Yes |
¡ñ PROFIBUS DP master |
No |
¡ñ PROFIBUS DP device |
No |
¡ñ Point-to-point connection |
No |
MPI |
¡ñ Transmission rate, max. |
187.5 kbit/s |
Services |
— PG/OP communication |
Yes |
— Routing |
Yes |
— Global data communication |
Yes |
— S7 basic communication |
Yes |
— S7 communication |
Yes; Only server, configured on one side |
— S7 communication, as client |
No |
— S7 communication, as server |
Yes |
2. Interface |
Interface type |
Integrated RS 485 interface |
Isolated |
Yes |
Interface types |
¡ñ RS 485 |
Yes |
¡ñ Output current of the interface, max. |
200 mA |
Protocols |
¡ñ MPI |
No |
¡ñ PROFIBUS DP master |
Yes |
¡ñ PROFIBUS DP device |
Yes |
¡ñ Point-to-point connection |
No |
PROFIBUS DP master |
¡ñ Transmission rate, max. |
12 Mbit/s |
¡ñ max. number of DP devices |
124; Per station |
Services |
— PG/OP communication |
Yes |
— Routing |
Yes |
— Global data communication |
No |
— S7 basic communication |
Yes; I blocks only |
— S7 communication |
Yes; Only server, configured on one side |
— S7 communication, as client |
No |
— S7 communication, as server |
Yes |
— Equidistance |
Yes |
— Isochronous mode |
Yes; OB 61 |
— SYNC/FREEZE |
Yes |
— activation/deactivation of DP devices |
Yes |
— max. number of DP devices that can be activated/deactivated at the same time |
8 |
— DPV1 |
Yes |
Address area |
— Inputs, max. |
2 048 byte |
— Outputs, max. |
2 048 byte |
User data per DP device |
— Inputs, max. |
244 byte |
— Outputs, max. |
244 byte |
2nd interface / PROFIBUS DP device / header |
¡ñ GSD file |
The latest GSD file is available at: http://www.siemens.com/profibus-gsd |
¡ñ Transmission rate, max. |
12 Mbit/s |
¡ñ automatic baud rate search |
Yes; only with passive interface |
¡ñ Address area, max. |
32 |
¡ñ User data per address area, max. |
32 byte |
Services |
— PG/OP communication |
Yes |
— Routing |
Yes; Only with active interface |
— Global data communication |
No |
— S7 basic communication |
No |
— S7 communication |
Yes; Only server, configured on one side |
— S7 communication, as client |
No |
— S7 communication, as server |
Yes |
— Direct data exchange (slave-to-slave communication) |
Yes |
— DPV1 |
No |
Transfer memory |
— Inputs |
244 byte |
— Outputs |
244 byte |
Protocols |
PROFIsafe |
No |
communication functions / header |
PG/OP communication |
Yes |
Data record routing |
Yes |
Global data communication |
¡ñ supported |
Yes |
¡ñ Number of GD loops, max. |
8 |
¡ñ Number of GD packets, max. |
8 |
¡ñ Number of GD packets, transmitter, max. |
8 |
¡ñ Number of GD packets, receiver, max. |
8 |
¡ñ Size of GD packets, max. |
22 byte |
¡ñ Size of GD packet (of which consistent), max. |
22 byte |
S7 basic communication |
¡ñ supported |
Yes |
¡ñ User data per job, max. |
76 byte |
¡ñ User data per job (of which consistent), max. |
76 byte; 76 bytes (with X_SEND or X_RCV); 64 bytes (with X_PUT or X_GET as server) |
S7 communication |
¡ñ supported |
Yes |
¡ñ as server |
Yes |
¡ñ as client |
Yes; Via CP and loadable FB |
¡ñ User data per job, max. |
180 byte; With PUT/GET |
¡ñ User data per job (of which consistent), max. |
240 byte; as server |
S5 compatible communication |
¡ñ supported |
Yes; via CP and loadable FC |
Number of connections |
¡ñ overall |
16 |
¡ñ usable for PG communication |
15 |
— reserved for PG communication |
1 |
— adjustable for PG communication, min. |
1 |
— adjustable for PG communication, max. |
15 |
¡ñ usable for OP communication |
15 |
— reserved for OP communication |
1 |
— adjustable for OP communication, min. |
1 |
— adjustable for OP communication, max. |
15 |
¡ñ usable for S7 basic communication |
12 |
— reserved for S7 basic communication |
0 |
— adjustable for S7 basic communication, min. |
0 |
— adjustable for S7 basic communication, max. |
12 |
S7 message functions |
Number of login stations for message functions, max. |
16; Depending on the configured connections for PG/OP and S7 basic communication |
Process diagnostic messages |
Yes |
simultaneously active Alarm_S blocks, max. |
300 |
Test commissioning functions |
Status block |
Yes; Up to 2 simultaneously |
Single step |
Yes |
Number of breakpoints |
4 |
Status/control |
¡ñ Status/control variable |
Yes |
¡ñ Variables |
Inputs, outputs, memory bits, DB, times, counters |
¡ñ Number of variables, max. |
30 |
— of which status variables, max. |
30 |
— of which control variables, max. |
14 |
Forcing |
¡ñ Forcing |
Yes |
¡ñ Forcing, variables |
Inputs, outputs |
¡ñ Number of variables, max. |
10 |
Diagnostic buffer |
¡ñ present |
Yes |
¡ñ Number of entries, max. |
500 |
— adjustable |
No |
— of which powerfail-proof |
100; Only the last 100 entries are retained |
¡ñ Number of entries readable in RUN, max. |
|
— adjustable |
Yes; From 10 to 499 |
— preset |
10 |
Service data |
¡ñ can be read out |
Yes |
Ambient conditions |
Ambient temperature during operation |
¡ñ min. |
0 °C |
¡ñ max. |
60 °C |
configuration / header |
Configuration software |
¡ñ STEP 7 |
Yes; V5.2 SP1 or higher with HW update |
configuration / programming / header |
¡ñ Command set |
see instruction list |
¡ñ Nesting levels |
8 |
¡ñ System functions (SFC) |
see instruction list |
¡ñ System function blocks (SFB) |
see instruction list |
Programming language |
— LAD |
Yes |
— FBD |
Yes |
— STL |
Yes |
— SCL |
Yes |
— CFC |
Yes |
— GRAPH |
Yes |
— HiGraph® |
Yes |
Know-how protection |
¡ñ User program protection/password protection |
Yes |
¡ñ Block encryption |
Yes; With S7 block Privacy |
Dimensions |
Width |
40 mm |
Height |
125 mm |
Depth |
130 mm |
Weights |
Weight, approx. |
290 g |