Please login to use this feature.
You can use this feature to add the product to your favourite list.
Close
You have removed this product from your favourite list.
Close
Please login to use this feature.
You can use this feature to add the company to your favourites list.
Close
This company has been removed from your favourite list.
Close
Please login to use this feature.
You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
You have removed this product from your favourite list.
Close
Daily Login Reward
Congratulations!
You¡¯ve earned your daily login reward for today!
5 NP PointHere are the reward you¡¯ve earned!
Check your Daily Login Rewards
Be sure to come back everyday for more rewards!
Thanks!
Scan and Whatsapp Me
Note: Some mobile phone default QR scanners cannot scan to open the WhatsApp App directly.
Cancel
Waktu
Pejabat
Isnin - Jumaat 9:00 AM - 5:00 AM
Sabtu - Ahad Closed
We′re closed on
Public Holiday
Get the latest
VG Instruments (SEA) Sdn Bhd
App for Android
Open
Closed
Selangor,Kuala Lumpur (KL),Kepong - Exhaust air cleaning in a wafer washing facility
12-Dec-2018
Exhaust air cleaning in a wafer washing facility
Process data
Medium
Pollutant-laden washing fluid, strongly acidic
Container
Counter-flow absorber, vertical construction
Temperature conditions
+25 °C
Process conditions
Condensate and vapour formation, strong turbulence in the washing liquid
Application
Wet chemical cleaning of silicon wafers creates unwanted nitrous gases. To make sure these gases do not exceed statutory limits, the exhaust flow is treated in a downstream exhaust air cleaning system. Flue gas scrubbers are one of the key steps in the treatment process. Washing fluid is pumped in a circuit via a pump station and sprayed finely into the scrubber to bind air pollutants to the liquid. The pollutant-laden washing fluid is periodically replaced with fresh water. In the storage tank, the level of the washing fluid is continuously monitored and kept constant during the process. The level measurement must be independent of the mixing ratio of the washing fluid as well as vapours and condensation in the tank and provide reliable measurement data.
Recommended products
VEGAFLEX 83
The solution
The PFA-coated, TDR level sensor VEGAFLEX 83 is ideal for use in aggressive media.
The sensor is mounted with a flange on one of the connection ports of the washing fluid storage tank.
A controller evaluates the signal from the sensor and ensures precise feed-in of fresh water.
User benefits
- Fail-safe operation of the washing facility through reliable measurement data
- Highly resistant, and therefore long-lasting, sensor
- Maintenance-free and thus more cost-efficient operation of the facility
- Optimal adaptation to the process
Measuring range - Distance
Hantar mesej anda ke VG Instruments (SEA) Sdn Bhd