Please login to use this feature.
You can use this feature to add the product to your favourite list.
Close
You have removed this product from your favourite list.
Close
Please login to use this feature.
You can use this feature to add the company to your favourites list.
Close
This company has been removed from your favourite list.
Close
Please login to use this feature.
You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
You have removed this product from your favourite list.
Close
Daily Login Reward
Congratulations!
You¡¯ve earned your daily login reward for today!
5 NP PointHere are the reward you¡¯ve earned!
Check your Daily Login Rewards
Be sure to come back everyday for more rewards!
Thanks!
Scan and Whatsapp Me
Note: Some mobile phone default QR scanners cannot scan to open the WhatsApp App directly.
Cancel
Johor - CAS BC-300KG Load Cell
13-Dec-2025
Features
•Accuracy:
-Selection is based on two principles: Firstly, the higher the resolution of the electronic scale head, the more accurate the display (should choose > 1500e). Secondly, the smaller the sensitivity of the load cell sensor, the higher the accuracy (should choose <=+_2mv)
•Durability:
-This is affected by two factors: the user and the quality of the electronic scale . Therefore, keep the electronic scale clean. Also, choose an electronic scale with a stainless steel or better quality outer casing. The electronic scale must have IP65 or higher certification from reputable manufactures.
Specification
| Max. Capacity |
Kgf |
30,60,100,150 |
Rated output
Zoro Balance |
mV/V
mV/V |
1.2 (Approx.)
0±0.06 |
Combined error
Repeatability
Creep for 30 min.
Temperature effect on
zero value
output value |
%
%
%
% / 10°C
% / 10°C |
0.03
0.01
0.03
0.028
0.015 |
Excitation
Recommended
Maximum
Resistance
Input
Output
Insulation |
V
V
Ω
Ω
MΩ |
10
15
420±20
350±3.5
>2,000 |
Compensated temperature range
Operating temperature range |
°C°C
|
-10 to ±40
-20 to +70 |
Send your message to RI Instrument