Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Green Energy Automation Sdn Bhd
Green Energy Automation Sdn Bhd 201201043627 (1028104-T)
Business
Hours
Monday - Friday 9:00 AM - 6:00 PM
Saturday 9:00 AM - 1:00 PM
Sunday Closed
Open Closed
Onesync AI SSM
VISITORS
60187891859
mychinkee WeChat QR
WeChat QR

Wechat ID: mychinkee

Business Nature:

Services Supplier

Johor,Johor Bahru (JB) - SITOP PSU100S 24 V/5 A stabilized power supply input: 120/230 V AC output: 24 V DC/5 A

23-Oct-2025

input
type of the power supply network 1-phase AC
supply voltage at AC Automatic range selection
supply voltage 120 V/230 V
input voltage 1 at AC 85 ... 132 V
input voltage 2 at AC 170 ... 264 V
wide range input No
overvoltage overload capability 2.3 × Vin rated, 1.3 ms
buffering time for rated value of the output current in the event of power failure minimum 20 ms
operating condition of the mains buffering at Vin = 93/187 V
line frequency 50/60 Hz
line frequency 47 ... 63 Hz
input current  
¡ñ at rated input voltage 120 V 2.34 A
¡ñ at rated input voltage 230 V 1.36 A
current limitation of inrush current at 25 °C maximum 40 A
I2t value maximum 1 A²·s
fuse protection type T 3,15 A/250 V (not accessible)
fuse protection type in the feeder Recommended miniature circuit breaker: from 6 A characteristic C
output
voltage curve at output Controlled, isolated DC voltage
output voltage at DC rated value 24 V
output voltage  
¡ñ at output 1 at DC rated value 24 V
   
output voltage adjustable Yes; via potentiometer
adjustable output voltage 22.8 ... 28 V
relative overall tolerance of the voltage 3 %
relative control precision of the output voltage  
¡ñ on slow fluctuation of input voltage 0.1 %
¡ñ on slow fluctuation of ohm loading 1 %
residual ripple  
¡ñ maximum 150 mV
¡ñ typical 30 mV
voltage peak  
¡ñ maximum 240 mV
¡ñ typical 140 mV
display version for normal operation Green LED for 24 V OK
type of signal at output Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK"
behavior of the output voltage when switching on Overshoot of Vout < 3 %
response delay maximum 0.3 s
voltage increase time of the output voltage  
¡ñ typical 15 ms
output current  
¡ñ rated value 5 A
¡ñ rated range 0 ... 6 A; 6 A up to +45°C; +60 ... +70 °C: Derating 1.6%/K
   
supplied active power typical 144 W
short-term overload current  
¡ñ on short-circuiting during the start-up typical 18 A
¡ñ at short-circuit during operation typical 18 A
duration of overloading capability for excess current  
¡ñ on short-circuiting during the start-up 800 ms
¡ñ at short-circuit during operation 800 ms
bridging of equipment Yes
number of parallel-switched equipment resources for increasing the power 2
efficiency
efficiency in percent 88 %
power loss [W]  
¡ñ at rated output voltage for rated value of the output current typical 16 W
closed-loop control
relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical 0.3 %
relative control precision of the output voltage at load step of resistive load 10/90/10 % typical 3 %
setting time  
¡ñ load step 10 to 90% typical 1 ms
¡ñ load step 90 to 10% typical 1 ms
protection and monitoring
design of the overvoltage protection protection against overvoltage in case of internal fault Vout < 33 V
property of the output short-circuit proof Yes
design of short-circuit protection Constant current characteristic
response value current limitation 6 ... 7.1 A
overcurrent overload capability  
¡ñ in normal operation overload capability 150 % Iout rated up to 5 s/min
enduring short circuit current RMS value  
¡ñ typical 7.1 A
safety
galvanic isolation between input and output Yes
galvanic isolation Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178
operating resource protection class Class I
leakage current  
¡ñ maximum 3.5 mA
¡ñ typical 0.4 mA
protection class IP IP20
EMC
standard  
¡ñ for emitted interference EN 55022 Class B
¡ñ for mains harmonics limitation EN 61000-3-2
¡ñ for interference immunity EN 61000-6-2
standards, specifications, approvals
certificate of suitability  
¡ñ CE marking Yes
¡ñ UL approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1)
¡ñ CSA approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1)
¡ñ UKCA marking Yes
¡ñ EAC approval Yes
¡ñ NEC Class 2 No
type of certification  
¡ñ BIS Yes; R-41183539, R-41188271
¡ñ CB-certificate Yes
MTBF at 40 °C 1 998 441 h
standards, specifications, approvals hazardous environments
certificate of suitability  
¡ñ IECEx No
¡ñ ATEX No
¡ñ ULhazloc approval No
¡ñ cCSAus, Class 1, Division 2 No
¡ñ FM registration No
standards, specifications, approvals marine classification
shipbuilding approval Yes
Marine classification association  
¡ñ American Bureau of Shipping Europe Ltd. (ABS) No
¡ñ French marine classification society (BV) Yes
¡ñ Det Norske Veritas (DNV) Yes
¡ñ Lloyds Register of Shipping (LRS) No
standards, specifications, approvals Environmental Product Declaration
Environmental Product Declaration Yes
global warming potential [CO2 eq]  
¡ñ total 447.2 kg
¡ñ during manufacturing 12.9 kg
¡ñ during operation 433.8 kg
¡ñ after end of life 0.37 kg
ambient conditions
ambient temperature  
¡ñ during operation -25 ... +70 °C; with natural convection
¡ñ during transport -40 ... +85 °C
¡ñ during storage -40 ... +85 °C
environmental category according to IEC 60721 Climate class 3K3, 5 ... 95% no condensation
connection method
type of electrical connection screw terminal
¡ñ at input L, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm² single-core/finely stranded
¡ñ at output +, -: 2 screw terminals each for 0.5 ... 2.5 mm²
¡ñ for auxiliary contacts Alarm signals: 2 screw terminals for 0.5 ... 2.5 mm²
¡ñ for signaling contact 2 screw terminals for 0.5 ... 2.5 mm²
mechanical data
width × height × depth of the enclosure 50 × 125 × 120 mm
installation width × mounting height 50 mm × 225 mm
required spacing  
¡ñ top 50 mm
¡ñ bottom 50 mm
¡ñ left 0 mm
¡ñ right 0 mm
fastening method Snaps onto DIN rail EN 60715 35x7.5/15
¡ñ DIN-rail mounting Yes
¡ñ S7 rail mounting No
¡ñ wall mounting No
housing can be lined up Yes
net weight 0.5 kg
accessories
electrical accessories Buffer module
mechanical accessories Device identification label 20 mm × 7 mm, pale turquoise 3RT1900-1SB20
Send your message to Green Energy Automation Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Green Energy Automation Sdn Bhd 201201043627 (1028104-T)
No. 2, Jalan Selatan 3/2, Taman Perindustrian Ringan Pulai, 81300 Skudai, Johor, Malaysia.

Tel:

Email:
Website: https://www.geasb.com
Website: https://geasb.newpages.com.my/
Website: https://geasb.onesync.my/

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • BR 18943
  • VN 7083
  • US 2559
  • AR 1816
  • CN 1357
  • EC 844
  • BD 458
  • RU 455
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us