Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Green Energy Automation Sdn Bhd
Green Energy Automation Sdn Bhd 201201043627 (1028104-T)
Business
Hours
Monday - Friday 9:00 AM - 6:00 PM
Saturday 9:00 AM - 1:00 PM
Sunday Closed
Open Closed
Onesync AI SSM
VISITORS
60187891859
mychinkee WeChat QR
WeChat QR

Wechat ID: mychinkee

Business Nature:

Services Supplier

Johor,Johor Bahru (JB) - SIRIUS soft starter S0 32 A, 15 kW/400 V, 40 ¡ãC 200-480 V AC, 110-230 V AC/DC Screw terminals

20-Oct-2025

General technical data
product brand name   SIRIUS
product designation   Soft starter
product feature    
¡ñ integrated bypass contact system   Yes
¡ñ thyristors   Yes
product function    
¡ñ intrinsic device protection   Yes
¡ñ motor overload protection   Yes
¡ñ evaluation of thermistor motor protection   No
¡ñ external reset   Yes
¡ñ adjustable current limitation   Yes
¡ñ inside-delta circuit   No
product component motor brake output   No
insulation voltage rated value V 600
degree of pollution   3, acc. to IEC 60947-4-2
blocking voltage of the thyristor maximum V 1 600
reference code according to EN 61346-2   Q
reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750   G
Power Electronics
operational current    
¡ñ at 40 °C rated value A 32
¡ñ at 50 °C rated value A 29
¡ñ at 60 °C rated value A 26
yielded mechanical performance for 3-phase motors    
¡ñ at 230 V    
— at standard circuit at 40 °C rated value kW 7.5
¡ñ at 400 V    
— at standard circuit at 40 °C rated value kW 15
yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated value hp 7.5
operating frequency rated value Hz 50 ... 60
relative negative tolerance of the operating frequency % -10
relative positive tolerance of the operating frequency % 10
operating voltage at standard circuit rated value V 200 ... 480
relative negative tolerance of the operating voltage at standard circuit % -15
relative positive tolerance of the operating voltage at standard circuit % 10
minimum load [%] % 20
adjustable motor current for motor overload protection minimum rated value A 17
continuous operating current [% of Ie] at 40 °C % 115
power loss [W] at operational current at 40 °C during operation typical W 13
Control circuit/ Control
type of voltage of the control supply voltage   AC/DC
control supply voltage frequency 1 rated value Hz 50
control supply voltage frequency 2 rated value Hz 60
relative negative tolerance of the control supply voltage frequency % -10
relative positive tolerance of the control supply voltage frequency % 10
control supply voltage 1 at AC at 50 Hz V 110 ... 230
control supply voltage 1 at AC at 60 Hz V 110 ... 230
relative negative tolerance of the control supply voltage at AC at 50 Hz % -15
relative positive tolerance of the control supply voltage at AC at 50 Hz % 10
relative negative tolerance of the control supply voltage at AC at 60 Hz % -15
relative positive tolerance of the control supply voltage at AC at 60 Hz % 10
control supply voltage 1 at DC V 110 ... 230
relative negative tolerance of the control supply voltage at DC % -15
relative positive tolerance of the control supply voltage at DC % 10
display version for fault signal   red
Mechanical data
size of engine control device   S0
width mm 45
height mm 125
depth mm 155
fastening method   screw and snap-on mounting
mounting position   With additional fan: With vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back Without additional fan: With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° t
required spacing with side-by-side mounting    
¡ñ upwards mm 60
¡ñ at the side mm 15
¡ñ downwards mm 40
wire length maximum m 300
number of poles for main current circuit   3
Connections/ Terminals
type of electrical connection    
¡ñ for main current circuit   screw-type terminals
¡ñ for auxiliary and control circuit   screw-type terminals
number of NC contacts for auxiliary contacts   0
number of NO contacts for auxiliary contacts   2
number of CO contacts for auxiliary contacts   1
type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point    
¡ñ solid   2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), max. 1x 10 mm²
¡ñ finely stranded with core end processing   2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²)
type of connectable conductor cross-sections for AWG cables for main contacts for box terminal    
¡ñ using the front clamping point   1x 8, 2x (16 ... 10)
type of connectable conductor cross-sections for auxiliary contacts    
¡ñ solid   2x (0.5 ... 2.5 mm²)
¡ñ finely stranded with core end processing   2x (0.5 ... 1.5 mm²)
type of connectable conductor cross-sections for AWG cables    
¡ñ for auxiliary contacts   2x (20 ... 14)
¡ñ for auxiliary contacts finely stranded with core end processing   2x (20 ... 16)
Ambient conditions
installation altitude at height above sea level m 5 000
environmental category    
¡ñ during transport according to IEC 60721   2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m)
¡ñ during storage according to IEC 60721   1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4
¡ñ during operation according to IEC 60721   3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6
ambient temperature    
¡ñ during operation °C -25 ... +60
¡ñ during storage °C -40 ... +80
derating temperature °C 40
protection class IP on the front according to IEC 60529   IP20
touch protection on the front according to IEC 60529   finger-safe, for vertical contact from the front
Environmental footprint
Environmental Product Declaration(EPD)   Yes
global warming potential [CO2 eq] total kg 121
global warming potential [CO2 eq] during manufacturing kg 4.24
global warming potential [CO2 eq] during sales kg 0.207
global warming potential [CO2 eq] during operation kg 117
global warming potential [CO2 eq] after end of life kg -0.229
UL/CSA ratings
yielded mechanical performance [hp] for 3-phase AC motor    
¡ñ at 220/230 V    
— at standard circuit at 50 °C rated value hp 7.5
¡ñ at 460/480 V    
— at standard circuit at 50 °C rated value hp 20
contact rating of auxiliary contacts according to UL   B300 / R300
Send your message to Green Energy Automation Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Green Energy Automation Sdn Bhd 201201043627 (1028104-T)
No. 2, Jalan Selatan 3/2, Taman Perindustrian Ringan Pulai, 81300 Skudai, Johor, Malaysia.

Tel:

Email:
Website: https://www.geasb.com
Website: https://geasb.newpages.com.my/
Website: https://geasb.onesync.my/

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • BR 35055
  • US 13261
  • VN 5004
  • MY 4158
  • MX 3217
  • AR 2842
  • GB 2766
  • CN 1833
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us