product brand name |
SIRIUS |
product designation |
Power contactor |
product type designation |
3RT6 |
General technical data |
size of contactor |
S0 |
product extension auxiliary switch |
Yes |
power loss [W] for rated value of the current |
|
¡ñ at AC in hot operating state per pole |
0.4 W |
¡ñ without load current share typical |
1.9 W |
type of calculation of power loss depending on pole |
quadratic |
insulation voltage rated value |
690 V |
degree of pollution |
3 |
surge voltage resistance rated value |
6 kV |
maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1 |
400 V |
shock resistance at rectangular impulse |
|
¡ñ at AC |
7,5g / 5 ms, 4,7g / 10 ms |
shock resistance with sine pulse |
|
¡ñ at AC |
11,8g / 5 ms, 7,4g / 10 ms |
mechanical service life (operating cycles) |
|
¡ñ of contactor typical |
10 000 000 |
¡ñ of the contactor with added auxiliary switch block typical |
10 000 000 |
Substance Prohibitance (Date) |
05/01/2012 |
Weight |
0.39 kg |
Ambient conditions |
installation altitude at height above sea level maximum |
2 000 m |
ambient temperature |
|
¡ñ during operation |
-25 ... +60 °C |
¡ñ during storage |
-55 ... +80 °C |
Main circuit |
number of poles for main current circuit |
3 |
number of NO contacts for main contacts |
3 |
number of NC contacts for main contacts |
0 |
operating voltage |
|
¡ñ at AC-3 rated value maximum |
690 V |
¡ñ at AC-3e rated value maximum |
690 V |
operational current |
|
¡ñ at AC-1 up to 690 V |
|
— at ambient temperature 40 °C rated value |
40 A |
— at ambient temperature 60 °C rated value |
35 A |
¡ñ at AC-3 |
|
— at 400 V rated value |
9 A |
— at 690 V rated value |
9 A |
¡ñ at AC-3e |
|
— at 400 V rated value |
9 A |
— at 690 V rated value |
9 A |
connectable conductor cross-section in main circuit at AC-1 |
|
¡ñ at 60 °C minimum permissible |
10 mm² |
¡ñ at 40 °C minimum permissible |
10 mm² |
operational current for approx. 200000 operating cycles at AC-4 |
|
¡ñ at 400 V rated value |
4.1 A |
¡ñ at 690 V rated value |
3.3 A |
operating power |
|
¡ñ at AC-1 |
|
— at 230 V rated value |
13.3 kW |
— at 230 V at 60 °C rated value |
13.3 kW |
— at 400 V at 60 °C rated value |
23 kW |
— at 690 V at 60 °C rated value |
40 kW |
¡ñ at AC-3 |
|
— at 230 V rated value |
2.2 kW |
— at 400 V rated value |
4 kW |
— at 690 V rated value |
7.5 kW |
¡ñ at AC-3e |
|
— at 230 V rated value |
2.2 kW |
— at 400 V rated value |
4 kW |
— at 690 V rated value |
7.5 kW |
operating power for approx. 200000 operating cycles at AC-4 |
|
¡ñ at 400 V rated value |
2 kW |
¡ñ at 690 V rated value |
2.5 kW |
no-load switching frequency |
|
¡ñ at AC |
5 000 1/h |
operating frequency |
|
¡ñ at AC-1 maximum |
1 000 1/h |
¡ñ at AC-3 maximum |
1 000 1/h |
¡ñ at AC-3e maximum |
1 000 1/h |
¡ñ at AC-4 maximum |
300 1/h |
Control circuit/ Control |
type of voltage of the control supply voltage |
AC |
control supply voltage at AC |
|
¡ñ at 50 Hz rated value |
230 V |
operating range factor control supply voltage rated value of magnet coil at AC |
|
¡ñ at 50 Hz |
0.8 ... 1.1 |
apparent pick-up power of magnet coil at AC |
|
¡ñ at 50 Hz |
65 VA |
inductive power factor with closing power of the coil |
|
¡ñ at 50 Hz |
0.82 |
apparent holding power of magnet coil at AC |
|
¡ñ at 50 Hz |
7.6 VA |
inductive power factor with the holding power of the coil |
|
¡ñ at 50 Hz |
0.25 |
Auxiliary circuit |
number of NC contacts for auxiliary contacts instantaneous contact |
1 |
number of NO contacts for auxiliary contacts instantaneous contact |
1 |
operational current at AC-12 maximum |
10 A |
operational current at AC-15 |
|
¡ñ at 230 V rated value |
10 A |
¡ñ at 400 V rated value |
3 A |
¡ñ at 690 V rated value |
1 A |
operational current at DC-12 |
|
¡ñ at 24 V rated value |
6 A |
¡ñ at 110 V rated value |
3 A |
¡ñ at 220 V rated value |
1 A |
operational current at DC-13 |
|
¡ñ at 24 V rated value |
6 A |
¡ñ at 110 V rated value |
1 A |
¡ñ at 220 V rated value |
0.3 A |
contact reliability of auxiliary contacts |
1 faulty switching per 100 million (17 V, 1 mA) |
UL/CSA ratings |
yielded mechanical performance [hp] for 3-phase AC motor at 460/480 V rated value |
5 hp |
Short-circuit protection |
design of the fuse link |
|
¡ñ for short-circuit protection of the main circuit |
|
— with type of coordination 1 required |
gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 63 A |
— with type of coordination 2 required |
gL/gG LV HRC 3NA, DIAZED 5SB, NEOZED 5SE: 25 A |
¡ñ for short-circuit protection of the auxiliary switch required |
fuse gL/gG: 10 A |
Installation/ mounting/ dimensions |
mounting position |
+/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface |
fastening method side-by-side mounting |
Yes |
fastening method |
screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 50022 |
height |
85 mm |
width |
45 mm |
depth |
97 mm |
required spacing |
|
¡ñ with side-by-side mounting |
|
— at the side |
0 mm |
Connections/ Terminals |
type of electrical connection |
|
¡ñ for main current circuit |
screw-type terminals |
¡ñ for auxiliary and control circuit |
screw-type terminals |
type of connectable conductor cross-sections for main contacts |
|
¡ñ solid or stranded |
2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²) |
¡ñ finely stranded with core end processing |
2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm² |
type of connectable conductor cross-sections |
|
¡ñ for auxiliary contacts |
|
— solid or stranded |
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
— finely stranded with core end processing |
2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) |
¡ñ for AWG cables for auxiliary contacts |
2x (20 ... 16), 2x (18 ... 14) |
Safety related data |
product function mirror contact according to IEC 60947-4-1 |
Yes |
Electrical Safety |
protection class IP on the front according to IEC 60529 |
IP20 |
touch protection on the front according to IEC 60529 |
finger-safe, for vertical contact from the front |