| input | ||
| type of the power supply network | 1-phase AC or DC | |
| supply voltage at AC | ||
| ¡ñ minimum rated value | 100 V | |
| ¡ñ maximum rated value | 240 V | |
| ¡ñ initial value | 85 V | |
| ¡ñ full-scale value | 264 V | |
| input voltage at DC | 110 ... 300 V | |
| wide range input | Yes | |
| overvoltage overload capability | 300 V AC for 1 s | |
| buffering time for rated value of the output current in the event of power failure minimum | 40 ms | |
| operating condition of the mains buffering | at Vin = 187 V | |
| line frequency | 50/60 Hz | |
| line frequency | 47 ... 63 Hz | |
| input current | ||
| ¡ñ at rated input voltage 120 V | 0.3 A | |
| ¡ñ at rated input voltage 230 V | 0.2 A | |
| current limitation of inrush current at 25 °C maximum | 20 A | |
| I2t value maximum | 0.8 A²·s | |
| fuse protection type | internal | |
| fuse protection type in the feeder | Recommended miniature circuit breaker: from 6 A characteristic B or from 2 A characteristic C | |
| output | ||
| voltage curve at output | Controlled, isolated DC voltage | |
| output voltage at DC rated value | 24 V | |
| output voltage | ||
| ¡ñ at output 1 at DC rated value | 24 V | |
| output voltage adjustable | No | |
| relative overall tolerance of the voltage | 3 % | |
| relative control precision of the output voltage | ||
| ¡ñ on slow fluctuation of input voltage | 0.1 % | |
| ¡ñ on slow fluctuation of ohm loading | 0.1 % | |
| residual ripple | ||
| ¡ñ maximum | 200 mV | |
| ¡ñ typical | 30 mV | |
| voltage peak | ||
| ¡ñ maximum | 300 mV | |
| ¡ñ typical | 50 mV | |
| display version for normal operation | Green LED for output voltage OK | |
| behavior of the output voltage when switching on | No overshoot of Vout (soft start) | |
| response delay maximum | 0.5 s | |
| voltage increase time of the output voltage | ||
| ¡ñ typical | 100 ms | |
| output current | ||
| ¡ñ rated value | 0.6 A | |
| ¡ñ rated range | 0 ... 0.6 A; +55 ... +70 °C: Derating 2%/K | |
| supplied active power typical | 14.4 W | |
| bridging of equipment | No | |
| efficiency | ||
| efficiency in percent | 81 % | |
| power loss [W] | ||
| ¡ñ at rated output voltage for rated value of the output current typical | 3.4 W | |
| ¡ñ during no-load operation maximum | 0.3 W | |
| closed-loop control | ||
| relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical | 0.2 % | |
| relative control precision of the output voltage at load step of resistive load 10/90/10 % typical | 2 % | |
| setting time | ||
| ¡ñ load step 10 to 90% typical | 1 ms | |
| ¡ñ load step 90 to 10% typical | 1 ms | |
| protection and monitoring | ||
| design of the overvoltage protection | Yes, according to EN 60950-1 | |
| property of the output short-circuit proof | Yes | |
| design of short-circuit protection | Constant current characteristic | |
| ¡ñ typical | 0.8 A | |
| overcurrent overload capability | ||
| ¡ñ when switching on | 150% Iout rated typ. 200 ms | |
| ¡ñ in normal operation | overload capability 150% Iout rated typ. 200 ms | |
| enduring short circuit current RMS value | ||
| ¡ñ maximum | 0.8 A | |
| measuring point for output current | No | |
| safety | ||
| galvanic isolation between input and output | Yes | |
| galvanic isolation | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 | |
| operating resource protection class | Class II (without protective conductor) | |
| protection class IP | IP20 | |
| EMC | ||
| standard | ||
| ¡ñ for emitted interference | EN 55022 Class B | |
| ¡ñ for mains harmonics limitation | not applicable | |
| ¡ñ for interference immunity | EN 61000-6-2 | |
| standards, specifications, approvals | ||
| certificate of suitability | ||
| ¡ñ CE marking | Yes | |
| ¡ñ UL approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-Recognized (UL 60950, CSA C22.2 No. 60950), File E151273, NEC class 2 (acc. to UL 1310) | |
| ¡ñ CSA approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cURus-Recognized (UL 60950, CSA C22.2 No. 60950), File E151273, NEC class 2 (acc. to UL 1310) | |
| ¡ñ EAC approval | Yes | |
| ¡ñ NEC Class 2 | Yes; according to UL1310, File E151273 | |
| ¡ñ SEMI F47 | Yes | |
| type of certification | ||
| ¡ñ CB-certificate | Yes | |
| MTBF at 40 °C | 4 415 040 h | |
| standards, specifications, approvals hazardous environments | ||
| certificate of suitability | ||
| ¡ñ IECEx | No | |
| ¡ñ ATEX | No | |
| ¡ñ ULhazloc approval | No | |
| ¡ñ cCSAus, Class 1, Division 2 | No | |
| ¡ñ FM registration | No | |
| standards, specifications, approvals marine classification | ||
| shipbuilding approval | Yes | |
| Marine classification association | ||
| ¡ñ American Bureau of Shipping Europe Ltd. (ABS) | Yes | |
| ¡ñ French marine classification society (BV) | Yes | |
| ¡ñ Det Norske Veritas (DNV) | Yes | |
| ¡ñ Lloyds Register of Shipping (LRS) | Yes | |
| standards, specifications, approvals Environmental Product Declaration | ||
| Environmental Product Declaration | Yes | |
| global warming potential [CO2 eq] | ||
| ¡ñ total | 94.5 kg | |
| ¡ñ during manufacturing | 1.3 kg | |
| ¡ñ during operation | 93.1 kg | |
| ¡ñ after end of life | 0.05 kg | |
| ambient conditions | ||
| ambient temperature | ||
| ¡ñ during operation | -25 ... +70 °C; with natural convection | |
| ¡ñ during transport | -40 ... +85 °C | |
| ¡ñ during storage | -40 ... +85 °C | |
| environmental category according to IEC 60721 | Climate class 3K3, 5 ... 95% no condensation | |
| connection method | ||
| type of electrical connection | screw terminal | |
| ¡ñ at input | L, N: 1 screw terminal each for 0.5 ... 2.5 mm2 single-core/finely stranded | |
| ¡ñ at output | +, -: 1 screw terminal each for 0.5 ... 2.5 mm² | |
| ¡ñ for auxiliary contacts | - | |
| mechanical data | ||
| width × height × depth of the enclosure | 18 × 90 × 53 mm | |
| installation width × mounting height | 18 mm × 130 mm | |
| required spacing | ||
| ¡ñ top | 20 mm | |
| ¡ñ bottom | 20 mm | |
| ¡ñ left | 0 mm | |
| ¡ñ right | 0 mm | |
| fastening method | Snaps onto DIN rail EN 60715 35x7.5/15, direct mounting in different mounting positions | |
| ¡ñ DIN-rail mounting | Yes | |
| ¡ñ S7 rail mounting | No | |
| ¡ñ wall mounting | Yes | |
| housing can be lined up | Yes | |
| net weight | 0.07 kg | |









 
            
             
             
		



 BR                                18181
BR                                18181                             US                                8046
US                                8046                             MY                                5172
MY                                5172                             VN                                4234
VN                                4234                             AR                                1862
AR                                1862                             CN                                1598
CN                                1598                             GB                                1563
GB                                1563                             MX                                1497
MX                                1497                             
         
        
 
        