Model\Item |
Port size [Note 1] |
Orifice size (ømm) |
Cv |
Valid area or section (mm²) |
Weight [Note 2] (g) |
Operating pressure differential | Proof pressure | ||
Mpa | psi | Mpa | psi | ||||||
2SA150 -15 |
1/2" |
15 .0 |
5.5 |
100 .0 |
575 |
Max: 1.0 Min: 0.05 |
Max: 100 Min: 10 |
1.5 |
220 |
2SA200 - 20 |
3/4" |
20 .0 |
9.5 |
170 .0 |
735 |
||||
2SA250 - 25 |
1" |
25 .0 |
12.5 |
220 .0 |
1035 |
||||
2SA320 -32 |
1 1/4" |
32 .0 |
23 |
420 |
2288 |
||||
2SA400 - 40 |
1 1/2" |
40 .0 |
31 |
560 |
2678 |
||||
2SA500 - 50 |
2" |
50 .0 |
49 |
880 |
3558 |
||||
Coil specifications
Valve type | Coil type | Power type | Frequency (Hz) | Voltage range | Electrical entry | Power consumption (VA/W) | Insulation | Temp. rise (ÚC) |
2SA150 2SA200 2SA250 |
CDA 110 CLA 110 |
AC |
50 | ±15% |
Terminal (CDA) Grommet (CLA) |
10.0VA | Class F |
50 |
60 | 8.0VA | 45 | ||||||
DC | - | ±10% | 6.5W | 50 | ||||
2SA320 2SA400 2SA500 |
CDA 160 CLA 160 |
AC |
50 | ±15% |
25.0VA | 65 | ||
60 | 22.0VA | 60 | ||||||
DC | - | ±10% | 12W | 50 |
Valve specifications
Acting | Internally piloted | ||||
Initial state | Normally closed | ||||
Adaptable fluid | Air , Water , Oil | ||||
Viscosity limit | Under 20 CST | ||||
Ambient and fluid temperature (ÚC) |
Water | Air | Oil | Ambient | |
Max. | 80 | 90 | 80 | 70 | |
Min. | 1 | -20 [Note 1] | -10 [Note 2] | -20 |