Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Sin Ma Air-Con & Electrical Sdn Bhd
Sin Ma Air-Con & Electrical Sdn Bhd 199801002672 (458798-H)
Business
Hours
Monday - Sunday 8:30 AM - 6:00 PM
Open Closed

Precision Install 精准安装(below 150micron)

Precision Install 精准安装(below 150micron)

For data center air conditioning systems (especially precision air conditioners or CRAC units), the vacuum level requirement mainly depends on whether the system has a compressor (with refrigerant) and the manufacturer’s specifications. Here are the industry-standard guidelines:


General Standard

  • Target vacuum level:
    500 microns or lower (≈0.66 mbar, ≈66 Pa)
    This is the common HVAC and data center standard to ensure the system is almost free of moisture and air.

  • High Standard / Best Practice:
    300 microns or lower
    Recommended for large refrigeration systems or those sensitive to moisture (e.g., low-temperature systems, long piping).


Why 500 microns?

  • A refrigeration system must be free of moisture and air; otherwise, it can cause:

    • Freeze-up (ice blockages)

    • Acid formation leading to compressor damage

    • Reduced heat transfer efficiency

  • Below 500 microns means the system pressure is close to a true vacuum, and most residual moisture has been removed.


Vacuum Procedure Recommendation

  1. Pull down to about 1500 microns first, hold for a few minutes to check for leaks.

  2. Then pull down to 500 microns or lower, and hold for 10–15 minutes without rising.

  3. If the pressure rises quickly after stopping the pump, there’s likely a leak or residual moisture.

     

    CRACУ



  4. 500 micron ≈0.66 mbar≈66 Pa
    HVAC

  5. /
    300 micron
    е


  6. 500 micron

    • Ч

  7. 500 micron ±

  8. 1500 micronй

  9. 500 micron 10~15

  10. úйδ

Main Office

Sin Ma Air-Con & Electrical Sdn Bhd 199801002672 (458798-H)
28, Jalan Persiaran Skudai 8, Pusat Perusahaan Skudai 8 Skudai, 81300 Johor Bahru, Johor, Malaysia.

Tel:

Email:
Website: https://www.sinmaaircon.com
Website: https://www.malaysiaaircon.com/
Website: https://sinmaaircon.newpages.com.my/
Website: https://sinmaaircon.onesync.my/

Other Office

Johor Jaya Branch
No 30, Jalan Dedap 4, Johor Jaya, 81100 Johor Bahru, Johor, Malaysia.

Tel:
Tel:
Email:

Kota Masai Branch
14, Jalan Ekoperniagaan 2, Taman Kota Masai, 81700 Pasir Gudang, Masai, Johor, Malaysia.

Tel:
Tel:
Email:

Kulai Branch
No. 235 & 236, Jln Kenanga 29/8, Bandar Indahpura, 81000 Kulai, Johor, Malaysia.

Tel:
Tel:
Email:

Sentosa Branch
123, Jalan Sutera 1, Taman Sentosa, 80150 Johor Bahru, Johor, Malaysia.

Skudai (TUTA) Branch
54, Jalan Pendekar 10, Taman Ungku Tun Aminah, 81300 Skudai, Johor, Malaysia

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • BR 25200
  • US 6800
  • AR 3135
  • CN 2965
  • EC 1563
  • SG 1003
  • AU 957
  • MX 910
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us