Batch Testing System for Improved Populated Circuit Board Productivity
OVERVIEW


Hioki testing systems continue to evolve so that the people who use them can shine. Reflecting its commitment to bring speed and comfort to the production floor by streamlining testing, Hioki’s proud to introduce a populated board tester designed with people in mind.
Key Features
- Slide-in mechanism simplifies installation and removal of test fixtures, reducing man-hours and workload.
- Extension range of options that reduces setup man-hours and boosts productivity.
- Numerous measurement parameters and detecting defects for a wide variety of inspections.
- Productivity, quality, and safety.
- Data creation support functionality: ATG function.
FA1220-02 | In-Circuit Tester |
The FA1220-02 does not have a CD or DVD drive. You will need to provide an external CD or DVD drive in order to use the included application disc.
SPECIFICATIONS
FA1220-02 Specifications Overview
Number of test points | Standard: 0 pins (scanner boards optional) Max. 2048 pins (expandable in blocks of 128 pins)* * The maximum number of active pins for each test type depends on the total number of scanner board pins installed in the product. |
|||||
---|---|---|---|---|---|---|
Number of test steps | Group data: 256 groups Round-robin short/open data: 2048 pins* Macro data: 2048 pins*/2048 steps (regardless of pin count) Component data: 10000 steps Charge data: 40 groups Pin contact data: 2048 pins* IC data: 500 steps (max. 2048 pins/step)* * The maximum number of active pins for each test type depends on the total number of scanner board pins installed in the product. |
|||||
Measurement unit | DC voltmeter: 800 μV f.s. to 25 V f.s., 8 ranges DC ammeter: 100 nA f.s. to 250 mA f.s., 9 ranges AC ammeter: 10 μA rms to 10 mA rms, 4 ranges HV voltmeter: 25 mV f.s. to 250 V f.s. (Requires E4210 and E4203) HV ammeter: 1.2 μA f.s. to 120 mA f.s. (Requires E4210 and E4203) |
|||||
Scanner unit | Switch type: analog (Scanner Board E4201 and E4202), read relay (Scanner Board E4203) Number of channels: 128 per board Input protection: ±15 V (Scanner Board E4201 and E4202), none (Scanner Board E4203) |
|||||
External I/O | Ethernet (LAN) 100Base-TX ×1 (please contact Hioki for communication with external devices.) | |||||
Control unit | - Measurement control Operating system: Real-time operating system Storage device: SD card (for booting system) - Main unit control Operating system: Windows 10 Pro (64-bit) Storage device: 64 GB SSD Operation: keyboard and mouse Display: 15-inch display Printer: E4243 (option) |
|||||
Power supply | Rated supply voltage: 100 to 240 V AC, 50 Hz/60 Hz Maximum power consumption: 1 kVA |
|||||
Dimensions and mass | 655 mm (25.79 in.) W × 1830 mm (72.05 in.) H × 705 mm (27.76 in.) D, 310 kg (10934.7 oz.) | |||||
Included accessories | Instruction Manual ×1, Test lead ×1, Application disc ×1, Positioning screws ×4, Maintenance key (for opening and closing the maintenance door) ×1 |
OPTIONS
Basic: Scanner boards (4)
SCANNER BOARD E4201
Semiconductor switches, 128 channels per board, cannot be combined with other scanner board models, factory option
SCANNER BOARD E4202
Semiconductor switches, no guarding, 128 channels per board, cannot be combined with other
scanner board models, factory option
SCANNER BOARD E4203
Read relay, 128 channels per board, cannot be combined with other scanner board models, factory option
RELAY POWER SUPPLY E4241
Required if adding two or more E4203 boards, Factory option
Basic: Connection (3)
ONE-TOUCH CONNECTOR E4268
1024 ch, factory option
ONE-TOUCH CONNECTOR E4269
2048 ch, factory option
64 SCANNER CABLE 1152-04
64 pins/cable
Testing data creation (2)
FAIL VISUALIZER UA1782
• Dedicated visualization software for Hioki electrical testing equipment and data creation systems
1220 DATA COMPOSITION SOFTWARE 1137-05
For editing data on a computer
Basic: Test fixtures (2)
TEST FIXTURE CP1167
PIN-BOARD 1160
Compatible with CP probes
Productivity (5)
STAMP DRIVE UNIT E4260
Can accommodate up to 4 units
ADDITIONAL STAMP DRIVE UNIT E4261
Can accommodate up to 3 units
ONE-TOUCH PRESS FUNCTION E4283
Start test simply by exerting light pressure on a wand-style switch.
AUTO RETEST FUNCTION E4284
Test fixture is upped and pressed down again to improve contact.
PLC UNIT E4285
Quality (8)
INSULATION MEASUREMENT FUNCTION E4210
Requires Scanner Board E4203
ONBOARD PROGRAMMING FUNCTION E4231
Compatible with EEPROM
PRINTER UNIT E4243
For printing test results
LARGE TEST FIXTURE ATTACHMENT E4262
Probable area: 400 (W) × 315 (D) mm
IONIZER UNIT E4287
Eliminates static electricity from board surface.
RECORDING PAPER 1197
58 mm × 30 m, 10 rolls
CALIBRATION UNIT FOR MEASUREMENT SECTION 1330
I2C TEST UNIT 1960-10
Requires 24 V power supply
Safety (9)
BACKUP POWER SUPPLY E4242
For use with control computer and LCD (UPS)
FIXTURE VERIFICATION FUNCTION E4263
For upper test fixture
FIXTURE VERIFICATION FUNCTION E4264
For lower test fixture
BOARD CONFIRMATION UNIT E4265
Support for up to 3¡¡detection sensors
TEST FIXTURE ID DETERMINATION UNIT E4266
Checks board and test fixture against test program
RESIDUAL PRESSURE EXHAUST UNIT E4270
Exhausts air while stopped to prevent lock.
LIGHT CURTAIN E4280
Detects any foreign objects entering the test area and halts movement of the upper fixture.
REAR SAFETY DOOR E4282
RECOVERY DISC FA1395
For restoring the operating system, settings, and other files to their state at the time of shipment