Compared with the international brands, the chemiluminescence immunoassay reagents have good consistency, the coincidence rate can reach more than 95%, and the detection precision can reach CV<2%.
Introduction:
Features:
Sample Tray£º
Disc design, up to 60 samples loading capacity per batch
The position of sample, standard product and quality control positions can be edited
Support emergency function.

Reagent Tray£º
Patented semiconductor refrigeration technology
Up to 30 reagent position on board with refrigeration at 2-8¡æ
Up to 30 items can be tested at the same time.
Washing and mixing module:
Three-level cleaning mode, higher cleaning efficiency;
Non-contact mixing to avoid cross-contamination.
Sample Probe:
Excellent rinsing system make carry-over ≤10-5
Liquid-level and blood coagulation detection system
Intelligent anti-collision function
Sampling volume: 15ul-100ul

RV Loading Module:
Independent reaction vessel
Up to 1200 pcs per batch with continues loading
Automatically supply reaction vessel
Intelligently detect the amount of RV
Incubation plate:
80 incubation positions
Constant 37°C incubation
Instrument Software:Flexible sample test mode: STAT function, automatic dilution, reset function, continuous loading
Reagent management: the remaining amount, calibration validity, expiry date management
Consumables management: continuous monitoring and low-level warning
Result management: store search, print and statistics, automatic unit conversion function
LIS/HIS connection
Auto daily maintenance
Models:
| Model | BKI1100 | BKI2200 |
| Throughput | 80T/H | 120T/H |
| Principle | Magnetic particle enzymatic chemiluminescence | |
| Modes of Operation | Random, Batch and STAT | |
| Separation method | Magnetic separation technology | |
| Sample Positions | 60 (Each position could be used as an emergency position) | |
| Reagent Positions | 30 pcs (2-8¡æ refrigeration) | |
| Incubation Positions | 50 | 80 |
| Time to 1st Result | 18 Minutes | |
| Sample Volume | 15-100μl | |
| Detection Precision | CV≤5% | |
| Carry-over Rate | ≤10-5 | |
| Correlation Coefficient | r≥0.99 | |
| Calibration Stability | 28 Days | |
| Calibration Type | 6/7-point calibration | |
| Software system | Windows 7/8/10, 32 or 64 bit | |
| Bi-direction, support HL7 protocol | ||
| Intuitive User Interface, Intelligent Data Management | ||
| Interface | TCP/IP Network interface | |
| Other Function | Liquid level detection | |
| Anti-collision function | ||
| Sample barcode scanning | ||
| Reagent radio frequency identification | ||
| Intelligent alarm prompt | ||
| Power Supply | AC110/220V£¬50/60Hz | |
| External Size (W*D*H) | 1120*735*513mm | 1305*770*1150mm |
| Net Weight | 130Kg | 220Kg |
| Package Size (WD*H) | 1303*873*854mm | 1608*898*1534mm |
| Gross Weight | 180kg | 294kg |
Reagent Menu:
|
Thyroid |
Anemia |
|
TSH |
FERRITIN |
|
TT4 |
VB12 |
|
TT3 |
FA |
|
FT4 |
|
|
FT3 |
Liver fibrosis |
|
TgAb |
C¢ô |
|
TPOAb |
LN |
|
TG |
HA |
|
Anti-TSHR |
PIIINP |
|
CT |
|
|
SHBG |
Hypertension |
|
ALD |
|
|
Fertility |
ACTH |
|
β-HCG |
Cortisol |
|
E2 |
Renin |
|
P |
|
|
T |
Growth |
|
PRL |
GH |
|
FSH |
|
|
LH |
Bone Metabolism |
|
DHEA-S |
BGP |
|
25-OH-Vit-D |
|
|
Tumor marker |
iPTH |
|
CA125 |
|
|
CA15-3 |
Pepsinogen |
|
CA199 |
PGII |
|
AFP |
|
|
CEA |
Kidney Function |
|
t-PSA |
β2-MG |
|
f-PSA |
|
|
Rheumatism |
|
|
Diabetes |
Anti-CCP |
|
C-P |
|
|
INS |
Pregnancy |
|
FE3 |
|
|
Cardiac marker |
PAPP-A |
|
cTnI |
Free-β-HCG |
|
CK-MB |
Inflammation |
|
MYO |
PCT |
|
NT-proBNP |
IL-6 |