- Aluminized FR fabric
- Radiant heat protection
- Molten metal splashes protection
- Reflect radiant heat
- Steel toe, boots height: 8"
- Made in Taiwan
-
Protective steel toe cap: The toe cap is reinforced with a steel toe cap to prevent objects from falling or puncturing and injuring the toes.
-
Flame resistance (ISO 15025): When tested according to the standard ISO 15025, the aluminum foil coating meets all the requirements of Class A1.
-
When tested according to the standard ISO 9151, the aluminum foil coat met the requirements of Class B1 for convective heat protection (ISO 9151) .
-
When tested according to the standard EN 6942, the aluminum foil coat meets the C3 requirement for radiant heat protection (EN 6942) . -
When tested according to the standard ISO 9185, the aluminum foil coat met the D2 requirement for protection against molten aluminum splashes (ISO 9185) .
-
When tested according to the standard ISO 9185, the aluminum foil coat achieved the highest level (E3) requirement for protection against molten iron splashes (ISO 9185) .
-
When tested according to the standard ISO 12127, the aluminum foil coat meets the F2 requirement for thermal protection (ISO 12127) .
|
Convection thermal protection – EU standard EN ISO 11612 |
||
|
Protection level |
Range of HTI 24 values (seconds) |
|
|
min. |
max. |
|
|
B1 |
4 |
< 10.0 |
|
B2 |
10.0 |
< 20.0 |
|
B3 |
20.0 |
– |
|
Radiant heat protection – EU standard EN ISO 11612 |
||
|
Protection level |
Heat transfer factor RHTI 24 (seconds) |
|
|
min. |
max. |
|
|
C1 |
7.0 |
< 20.0 |
|
C2 |
20.0 |
< 50.0 |
|
C3 |
50.0 |
< 95.0 |
|
C4 |
95.0 |
– |
|
Protection against molten aluminum splashes – EU Standard EN ISO 11612 |
||
|
Protection level |
Molten aluminum splash (grams) |
|
|
min. |
max. |
|
|
D1 |
100 |
< 200 |
|
D2 |
200 |
< 350 |
|
D3 |
350 |
– |
|
Protection against molten iron splashes – EU Standard EN ISO 11612 |
||
|
Protection level |
Molten iron splash (grams) |
|
|
min. |
max. |
|
|
E1 |
60 |
< 120 |
|
E2 |
120 |
< 200 |
|
E3 |
200 |
– |
|
Thermal protection against contact – EU standard EN ISO 11612 |
||
|
Protection level |
Protection time (seconds) |
|
|
min. |
max. |
|
|
F1 |
5.0 |
< 10.0 |
|
F2 |
10.0 |
< 15.0 |
|
F3 |
15.0 |
– |



BR 21282
US 5309
VN 5056
AR 3341
MY 3209
MX 2739
VE 1779
CO 1518