Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
EKG M & E SDN BHD
EKG M & E SDN BHD 201201033712 (1018200-D)
Business
Hours
Monday - Friday 9:00 AM - 5:30 PM
Saturday 9:00 AM - 1:00 PM
Sunday Closed
We′re closed on Public Holiday
Open Closed
Onesync AI SSM
VISITORS

11-May-2026

Variable Speed Drive (VSD) AHU Optimization by EKG (Malaysia) SDN BHD

In the context of the EECA 2024 and MS 1525 standards, Variable Speed Drive (VSD) optimization is the primary mechanical strategy for reducing Building Energy Intensity (BEI). Since Air Handling Units (AHUs) are designed for "worst-case" peak cooling loads (which occur less than 5% of the time in Malaysia), a system without VSD modulation is essentially wasting energy 95% of the year.

At EKG (Malaysia) SDN BHD, we specialize in retrofitting and engineering AHUs with VSD technology to transform them from static energy consumers into dynamic, star-rated assets.


1. The Physics of Savings: The Affinity Laws

The core justification for VSD optimization is found in the Fan Laws (or Affinity Laws). These laws dictate that the power consumed by a fan motor is proportional to the cube of its speed:

$$P_2 = P_1 \times \left( \frac{n_2}{n_1} \right)^3$$
  • The Result: Reducing your fan speed by just 20% lowers the power consumption by nearly 50%.

     

  • The Impact: In a 24/7 facility, this optimization can reduce annual HVAC electricity costs by 30% to 60%, directly moving your building into a higher EECA 2024 Star Rating bracket.


2. Operational Optimization Strategies

A. Demand-Controlled Ventilation (DCV)

The VSD is linked to CO2 and Occupancy sensors.

 

  • Logic: When meeting rooms or office floors are at 50% capacity, the VSD ramps the AHU motor down to match the actual fresh air and cooling requirement.

  • Sustainability: This ensures the building meets the MS 1525 air quality standards without the energy penalty of constant-volume over-ventilation.

B. Static Pressure Reset

Traditional systems maintain a constant (and often unnecessarily high) static pressure in the ductwork.

  • Optimization: Our Smart AHU systems use VSDs to dynamically lower the static pressure setpoint based on the position of the furthest VAV (Variable Air Volume) dampers. Lowering static pressure allows the motor to run at a lower frequency, extending the lifespan of the bearings and belts.

C. Soft Start Capability

A major hidden cost of AHU operation is the "inrush current" when a motor starts across-the-line.

  • Benefit: VSDs provide a "Soft Start," gradually ramping up the speed. This eliminates electrical demand spikes (reducing TNB peak demand charges) and prevents mechanical stress on the fan belts and motor shafts.

     


3. Comparison: Constant Speed vs. VSD-Optimized AHU

Feature Constant Speed AHU VSD-Optimized AHU (EKG)
Control Logic On/Off (Binary) Modulating (0-100%)
Energy Consumption 100% at all times Matches Actual Building Load
Mechanical Wear High (Hard Starts/Stops) Low (Soft Starts/Smooth Operation)
Humidity Control Variable / Unstable Precise (via Air-Dwell Time Control)
Noise Level Constant High Decibels Quiet (during part-load)
Compliance High Risk under EECA 2024 Star-Rating Optimized

4. VSD vs. EC Plug Fan: The 2026 Selection Criteria

While VSDs are excellent for retrofitting existing AC induction motors, for new installations, EKG often recommends EC (Electronically Commutated) Plug Fans.

  • VSD Retrofit: Best for large existing motors (over 15kW) where the mechanical structure is still sound but requires modulation.

  • EC Fan Integration: Best for new AHU designs or total motor replacements. EC fans integrate the VSD electronics directly into the motor housing, achieving IE5 efficiency with zero belt-drive losses.


Why Partner with EKG (Malaysia) SDN BHD?

  • Technical Integrity: We provide the Harmonic Analysis and energy calculation reports required for Suruhanjaya Tenaga (ST) energy audits.

  • 3D BIM Coordination: We use 3D modeling to ensure VSD enclosures are positioned for optimal cooling and maintenance access, preventing overheating—the #1 cause of VSD failure in Malaysia.

  • BOMBA-Compliant Safety: All control panels and VSD housing meet international fire safety and electrical protection standards.

Is your facility's energy intensity too high for the mandatory 2026 audits? Contact EKG (Malaysia) SDN BHD today for a technical VSD optimization audit. We specialize in modernizing HVAC infrastructure to lower your BEI and protect your operational budget.

How would you like to proceed with your motor performance audit?

Send your message to EKG M & E SDN BHD
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

EKG M & E SDN BHD 201201033712 (1018200-D)
27-2 & 27-3, Jalan Kuchai Maju, Kuchai Entrepreneur¡¯s Park, Off Jalan Kuchai Lama, 58200 Kuala Lumpur, Malaysia.

Tel:

Email:
Website: https://www.eakon.com.my
Website: https://eakon.newpages.com.my/
Website: https://eakon.onesync.my/

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us