Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
EKG M & E SDN BHD
EKG M & E SDN BHD 201201033712 (1018200-D)
Business
Hours
Monday - Friday 9:00 AM - 5:30 PM
Saturday 9:00 AM - 1:00 PM
Sunday Closed
We′re closed on Public Holiday
Open Closed
Onesync AI SSM
VISITORS

10-Apr-2026

VAV System Balancing by EKG M&E Sdn Bhd

In the large-scale commercial towers and mixed-use developments of Kuala Lumpur and Selangor, a Variable Air Volume (VAV) system is only as effective as its Testing, Adjusting, and Balancing (TAB). Without a rigorous balancing process, a system becomes a series of competing demands: zones closest to the fan are over-cooled and noisy, while distant "starved" zones suffer from stuffiness and poor thermal control.

EKG M&E Sdn Bhd provides specialized TAB services that ensure every zone receives its design airflow, strictly complying with MS 1525 energy efficiency standards and the EECA 2024 mandates.


The Precision Process of VAV Balancing

Unlike constant volume systems, balancing a multi-zone VAV network is a multi-stage process that requires synchronizing the central plant with dozens of individual terminal units.

1. Full-Flow Main Header Balancing

We first drive all VAV boxes to their Maximum Cooling (Vmax) positions. This allows us to balance the main headers and ensure the central fan can meet the cumulative peak demand of the building.

  • Proportioning Branches: We adjust the main branch dampers so that each floor or sector receives its fair share of air relative to its design capacity.

2. Terminal Unit Calibration (Vmax & Vmin)

Every VAV box must be individually verified against its digital setpoints.

  • Vmax Verification: We use calibrated Airflow Capture Hoods or Pitot Tube Traverses to verify that the box delivers its peak design Liters per Second (L/s).

  • Vmin Verification: We test the "Minimum Flow" setpoint to ensure that even when cooling is not required, enough fresh air is provided to meet DOSH IAQ (Indoor Air Quality) standards.


Critical Operational & Energy Benefits

As a specialized M&E contractor, EKG ensures your system balancing supports both occupant comfort and the bottom line:

  • TNB Energy Savings (Static Pressure Reset):

    The goal of TAB is to find the lowest possible static pressure that still satisfies the "most demanding" VAV box. By lowering this setpoint, the Air Handling Unit’s Variable Frequency Drive (VFD) can run at a lower frequency, directly reducing your monthly TNB electricity bill.

  • Elimination of "Cold Air Dumping" & Noise:

    Imbalanced systems often have excessively high pressure in certain branches, causing high-pitched "whistling" at the diffusers and cold drafts. Proper balancing restores a quiet, laminar airflow profile.

  • Improved Humidity Control:

    In the humid Malaysian climate, imbalanced airflow leads to uneven dehumidification. Correct balancing ensures that air moves across the cooling coils at the designed velocity, preventing "low Delta-T" and keeping indoor relative humidity within the comfortable 55% – 70% range.


Performance Matrix: Unbalanced vs. EKG Balanced VAV

Feature Unbalanced VAV Network EKG Balanced VAV System
Airflow Distribution Strong near fan / Weak at ends Uniform / Design-Compliant
Occupant Comfort Frequent Hot/Cold complaints High (Stable plus-minus 0.5C)
System Noise High (Whistling/Turbulence) Low (Whisper-Quiet)
Energy Usage High (Fan over-compensating) Optimized (Lowest Fan Power)
IAQ Compliance Uncertain Guaranteed (Verified Vmin)
Maintenance High (Frequent adjustments) Low (Stable System State)

Why Choose EKG M&E Sdn Bhd?

  • Total 3D BIM Coordination: We model the ducting and VAV placements in 3D to identify "clash-free" locations for Test Holes and access panels, ensuring that balancing can be performed accurately and safely within tight ceiling voids.

  • Certified Instrumentation: Our TAB technicians utilize NATA/SIRIM calibrated anemometers, manometers, and capture hoods to ensure that our measurements are accurate within plus-minus 5% to 10% of design values.

  • Turnkey Validation: Every project concludes with a comprehensive TAB Report, which is essential for your annual Local Exhaust Ventilation (LEV) certification or Green Building (GBI/LEED) credits.

Is your office environment inconsistent or your energy bills higher than expected? Contact EKG M&E Sdn Bhd today for a professional VAV system balancing audit and restore the performance of your workspace.

Send your message to EKG M & E SDN BHD
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

EKG M & E SDN BHD 201201033712 (1018200-D)
27-2 & 27-3, Jalan Kuchai Maju, Kuchai Entrepreneur¡¯s Park, Off Jalan Kuchai Lama, 58200 Kuala Lumpur, Malaysia.

Tel:

Email:
Website: https://www.eakon.com.my
Website: https://eakon.newpages.com.my/
Website: https://eakon.onesync.my/

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us