Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
EKG M & E SDN BHD
EKG M & E SDN BHD 201201033712 (1018200-D)
Business
Hours
Monday - Friday 9:00 AM - 5:30 PM
Saturday 9:00 AM - 1:00 PM
Sunday Closed
We′re closed on Public Holiday
Open Closed
Onesync AI SSM
VISITORS

10-Apr-2026

AC Zone Control Systems by EKG M&E Sdn Bhd

In the commercial high-rises and mixed-use developments of Kuala Lumpur and Selangor, maintaining consistent thermal comfort is a significant challenge. AC Zone Control Systems allow a single central Air Handling Unit (AHU) to serve multiple rooms with varying cooling demands. By retrofitting traditional constant-volume systems with modern zone controls, building managers can eliminate the common problem of "hot spots" in one office while another is overcooled, all while significantly lowering operational costs.

EKG M&E Sdn Bhd specializes in the precision retrofitting of VAV systems, ensuring your facility complies with MS 1525 energy standards and the EECA 2024 mandates.


The Mechanics of Zonal Precision

An AC Zone Control system transforms a building’s HVAC from a "one-size-fits-all" utility into a responsive, demand-based network.

1. Smart Dampers & Actuators

At the heart of every zone are motorized dampers installed within the ductwork.

  • Variable Frequency Response: When a specific zone reaches its setpoint, the VAV Box actuator modulates the damper to reduce airflow rather than turning off the cooling entirely. This prevents the "stagnant air" feeling often associated with basic on/off systems.

  • EKG Retrofit Advantage: We replace aging, pneumatic actuators with high-precision digital (DDC) actuators that provide real-time feedback to the central Building Management System (BMS).

2. Localized Thermostat Integration

Each zone is equipped with its own dedicated sensor.

  • Individualized Comfort: Occupants in a server room can maintain a crisp 20°C while the adjacent open-plan office stays at a comfortable 24°C.

  • Occupancy Sensing: We can integrate PIR (Passive Infrared) sensors that automatically reset the zone to "Economy Mode" when no movement is detected, preventing the cooling of empty rooms.


Critical Operational & Energy Benefits

As a specialized M&E contractor, EKG ensures your zone control retrofit supports both occupant satisfaction and the bottom line:

  • TNB Energy Savings (Up to 30%):

    By only delivering the exact volume of air required for each zone, the static pressure in the main duct increases. This allows the AHU’s Variable Frequency Drive (VFD) to ramp down the fan speed. Reducing fan speed by just 20% can cut energy consumption by nearly 50% due to the affinity laws of fans.

  • Extended Equipment Lifecycle:

    Zone control prevents the AHU from "short-cycling." By maintaining a steady, modulated load, there is less mechanical wear on the fan motors, bearings, and chilled water valves, leading to reduced maintenance costs in the long term.

  • Improved Humidity Control:

    In the humid Malaysian climate, overcooling leads to high relative humidity and potential mold issues. Precise zone control ensures that air is supplied at the correct volume to maintain the "Dew Point," keeping indoor environments dry and healthy.


Performance Matrix: Constant Volume vs. Retrofitted Zone Control

Feature Constant Air Volume (CAV) EKG VAV Zone Control
Temperature Stability High Fluctuation Stable / Precise
Occupant Comfort Poor (Hot/Cold spots) High (Individualized)
Energy Usage 100% Load Always Demand-Controlled (Low TNB)
Fan Control Fixed Speed VFD Optimized (Variable)
BMS Integration Limited / Analog Full Digital Integration
Operational Cost High Low (ROI within 18-24 months)

Why Choose EKG M&E Sdn Bhd?

  • Total 3D BIM Coordination: We model the ducting and VAV box placements in 3D to ensure "clash-free" installation within tight ceiling voids common in older Kuala Lumpur buildings.

  • T&C Excellence: We provide full Testing & Commissioning (T&C), including Air Balancing reports and Static Pressure sensor calibration to ensure the system reacts perfectly to changing occupancy loads.

  • Strategic Regional Support: Based in Kuala Lumpur, we provide site audits and professional retrofits for corporate offices, hotels, hospitals, and shopping malls across Malaysia.

Is your building suffering from uneven cooling or high electricity bills? Contact EKG M&E Sdn Bhd today for a professional AC Zone Control audit and a technical proposal that prioritizes comfort, durability, and energy efficiency.

Send your message to EKG M & E SDN BHD
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

EKG M & E SDN BHD 201201033712 (1018200-D)
27-2 & 27-3, Jalan Kuchai Maju, Kuchai Entrepreneur¡¯s Park, Off Jalan Kuchai Lama, 58200 Kuala Lumpur, Malaysia.

Tel:

Email:
Website: https://www.eakon.com.my
Website: https://eakon.newpages.com.my/
Website: https://eakon.onesync.my/

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us