Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
EKG M & E SDN BHD
EKG M & E SDN BHD 201201033712 (1018200-D)
Business
Hours
Monday - Friday 9:00 AM - 5:30 PM
Saturday 9:00 AM - 1:00 PM
Sunday Closed
We′re closed on Public Holiday
Open Closed
SSM
VISITORS

26-Mar-2026

Multi-Zone CO2 Control Logic | 2026 Engineering Standards

In 2026, Multi-Zone CO2 Control Logic is the gold standard for managing large commercial floorplates in Malaysia. Under the EECA 2024 and the DOSH ICOP IAQ 2026, a "one-size-fits-all" ventilation approach is no longer compliant for buildings over 8,000 square meters. Multi-zone logic ensures that fresh air is directed precisely where people are gathered—such as a packed boardroom—while reducing airflow to empty perimeter offices.

At EKG M&E, we utilize 34 years of mechanical depth to program these complex "many-to-one" relationships, ensuring your Building Energy Index (BEI) remains within the mandatory 5-star rating bracket.


1. The 2026 "High-Select" Logic (The Winner-Takes-All)

In a multi-zone system (like a VAV system), multiple CO2 sensors across different rooms report to a single Air Handling Unit (AHU). We utilize High-Select Logic to ensure safety:

  • The Voting System: The BMS (Building Management System) constantly polls all sensors in the network (e.g., Zone A, B, and C).

  • The Command: The AHU’s fresh air damper and Variable Frequency Drive (VFD) respond to the highest CO2 reading among all zones.

  • Safety Margin: If Zone A is at 950 ppm and Zone B is at 500 ppm, the AHU ignores the average and treats the entire system as if it were at 950 ppm, ramping up the fan to satisfy the "worst-case" zone.


2. ASHRAE 62.1-2025: System Ventilation Efficiency (Ev)

The 2026 Malaysian standard adopts the latest ASHRAE 62.1-2025 calculations for multi-zone recirculating systems. This requires calculating the System Ventilation Efficiency (Ev).

  • Dynamic Reset: The control panel doesn't just look at CO2; it calculates the "Critical Zone"—the room with the highest fraction of outdoor air required.

  • Dampening the Waste: In 2026, we utilize Dynamic Fraction Reset. If the critical zone's demand drops, the BMS automatically resets the outdoor air intake, preventing "Over-Ventilation" in the non-critical zones.

  • Compliance: This precise tracking is a prerequisite for LEED v5 and GBI multi-zone credits.


3. EECA 2024: The Financial Impact of Multi-Zone Logic

Under the EECA 2024, multi-zone logic is your most powerful tool for achieving the 32% CO2 emission reduction targeted by the National Energy Transition Roadmap.

  • VFD Modulation: Instead of the fan running at a fixed 50Hz, the multi-zone logic provides a "Summed Demand" signal to the VFD.

  • The Cube Law Savings: By using multi-zone logic to prevent the fan from running at 100% when only one small zone is occupied, we apply the Cube Law. Reducing the average fan speed by 30% across the building’s operational hours can slash your fan's energy bill by over 60%.

  • Audit Trail: The Registered Energy Manager (REM) uses the multi-zone trend logs to prove that the building is not "Cooling Empty Spaces," a key metric for annual energy audits.


4. Mechanical Health: FFT Vibration & Damper Stress

Multi-zone systems involve constant movement of VAV dampers and VFD speed changes. To prevent mechanical fatigue, we apply specialized diagnostics:

  • FFT Vibration Audit: We use Fast Fourier Transform (FFT) analysis on the main AHU to ensure that the constant "Ramping" of the VFD (driven by multi-zone demand) does not hit a Resonant Frequency that could shake the ductwork or damage bearings.

  • Hysteresis Tuning: We program a "Deadband" (typically 50 ppm) into the logic. This prevents the dampers from "hunting" or oscillating, which reduces wear on the actuator motors and extends the system's life cycle.


Why Trust EKG M&E for Multi-Zone Logic?

  • 34 Years of Engineering Depth: We understand the complex math behind multi-zone air balancing in Malaysia's tropical humidity.

  • BMS Expertise: We are proficient in BACnet and Modbus integration, ensuring your sensors, VAV boxes, and VFDs speak the same language.

  • Audit-Ready Reporting: We provide the Zone-by-Zone Heatmaps required for 2026 DOSH and GBI submissions.

Send your message to EKG M & E SDN BHD
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

EKG M & E SDN BHD 201201033712 (1018200-D)
27-2 & 27-3, Jalan Kuchai Maju, Kuchai Entrepreneur¡¯s Park, Off Jalan Kuchai Lama, 58200 Kuala Lumpur, Malaysia.

Tel:

Email:
Website: https://www.eakon.com.my
Website: https://eakon.newpages.com.my/
Website: https://eakon.onesync.my/

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us