Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
EKG M & E SDN BHD
EKG M & E SDN BHD 201201033712 (1018200-D)
Business
Hours
Monday - Friday 9:00 AM - 5:30 PM
Saturday 9:00 AM - 1:00 PM
Sunday Closed
We′re closed on Public Holiday
Open Closed
SSM
VISITORS

26-Mar-2026

CO2 Level Controller | 2026 HVAC & Safety Intelligence

In 2026, a CO2 Level Controller is no longer just a standalone monitor; it is the "Command Module" for modern air management in Malaysia. Driven by the DOSH ICOP IAQ 2026 and the Energy Efficiency and Conservation Act (EECA) 2024, these devices are essential for maintaining the mandatory 1,000 ppm ventilation ceiling. They act as a bridge, translating air quality data into mechanical action—modulating fans, opening dampers, or triggering alarms to ensure occupant safety and energy savings.

At EKG M&E, we apply 34 years of engineering depth to integrate $CO_2$ controllers that align with your building's Registered Energy Manager (REM) goals and federal safety audits.


1. 2026 Compliance: The DOSH "Command" Standard

Under the DOSH 2026 framework, a controller must do more than just read levels; it must actively manage the environment to prevent "Inadequate Ventilation" (defined as any time levels exceed 1,000 ppm).

  • NDIR Precision: All 2026-compliant controllers utilize Non-Dispersive Infrared (NDIR) sensors. These are resistant to "cross-sensitivity" from other gases, ensuring your fans only ramp up when human-emitted $CO_2$ is actually present.

  • Control Thresholds:

    • Normal (Green): < 800 ppm. System operates at minimum fresh air rates for energy conservation.

    • Caution (Yellow): 800 - 1,000 ppm. Controller begins to modulate the Variable Frequency Drive (VFD) or opens fresh air dampers.

    • Alarm (Red): > 1,000 ppm. Controller triggers full ventilation and logs the event for DOSH audit purposes.


2. EECA 2024: VFD Modulation & The Cube Law

The EECA 2024 requires building owners to optimize HVAC power consumption. The $CO_2$ controller is the primary tool for achieving a 4 or 5-Star Energy Intensity Label.

 
  • Proportional Control (0–10V): Instead of a simple "On/Off" switch, modern controllers like the Vaisala GMW90 Series provide a linear 0–10V or 4–20mA signal to the fan's VFD.

  • The Cube Law Advantage: Following the Cube Law, if the CO2 controller determines the room is only 50% full and slows the fan by 20%, the energy consumption drops by nearly 50%. This granular control is essential for maintaining your building's Energy Efficiency Certificate.


 

3. Mechanical Health: FFT Vibration & Signal Integrity

A controller is only effective if its signal is clean and its mounting is stable.

  • Vibration Diagnostics: We use Fast Fourier Transform (FFT) analysis during installation to ensure the controller is not mounted near vibrating mechanical shafts. Physical vibration can cause "Sensor Jitter," leading to false CO2 spikes and erratic fan behavior.

  • Resonance Protection: We program the controller's logic to avoid "Hunting"—the constant, rapid toggling of the VFD that can cause mechanical fatigue. By setting a Hysteresis (e.g., a 50 ppm buffer), we ensure smooth, energy-efficient transitions.


Why Trust EKG M&E for CO2 Control?

  • 34 Years of Engineering Depth: Malaysia's specialists in the synergy between sensor logic and mechanical HVAC performance.

  • Audit-Ready Integration: We provide the Setpoint Maps, VFD-Energy ROI data, and DOSH-compliant IAQ Logs.

  • Expert Calibration: We handle the mandatory NIST-traceable calibration cycles required to keep your building's safety certification valid.

Send your message to EKG M & E SDN BHD
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

EKG M & E SDN BHD 201201033712 (1018200-D)
27-2 & 27-3, Jalan Kuchai Maju, Kuchai Entrepreneur¡¯s Park, Off Jalan Kuchai Lama, 58200 Kuala Lumpur, Malaysia.

Tel:

Email:
Website: https://www.eakon.com.my
Website: https://eakon.newpages.com.my/
Website: https://eakon.onesync.my/

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us