Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Excel Test Sdn Bhd
Excel Test Sdn Bhd 201701016145 (1230309-H)
Featured Merchant SSM
Social Media Link
  • facebook
Business Nature:

Supplier

Selangor,Kuala Lumpur (KL),Petaling Jaya - LEFOO LFH71 Intrinsically Safe Temperature & Humidity Transmitter

28-Jan-2026

DESCRIPTION

LFH71 is a temperature and humidity transmitter that can be applied in hazardous occasions.

The product adopts cast aluminum housing with high protection level, which is suitable for the monitoring of natural gas pipeline network, air supply system of power plant, pharmaceutical factory clean room and other industrial environments with complicated working conditions.

The product adopts imported temperature and humidity sensors, with high precision and fast response.

The product is divided into intrinsically safe explosion-proof (with display), intrinsically safe dust explosion-proof two models, of which intrinsically safe explosion-proof can work in Zone 0, Zone 1, Zone 2; intrinsically safe dust explosion-proof can work in Zone 20, Zone 21, Zone 22.

FEATURES

  • Intrinsically safe, dust explosion-proof certification
  • Cast aluminium housing, protection level IP65
  • LCD, temperature and humidity dual display
  • Imported sensors, high precision, fast response
  • Conforms to CE, ROHS standards

TECHNICAL DATA

RELATIVE HUMIDITY
Sensor Digital
Measuring Range 0%~100%RH
Output 4~20mA(two wire)
Response Time ≤15s (20°C, Slow flow air)
Accuracy ±3%@20°C & 20~80%RH
RELATIVE TEMPERATURE
Sensor Digital
Range 0~50°C£¬-20~60°C etc
Output 4~20mA(two wire)
Accuracy ±0.3°C@20'c (Refer Accuracy Curve Chart)
SAFETY PARAMETERS
Explosion-proof Marking With display: Ex ia IIC T6/T4 Ga

Without display: Ex ia IIC T6/T4 Ga; Ex ia IIIC T200 85°C/T200 135°C Da
Explosion-proof Certificate CE24.2060X
Intrinsically Safe Parameters (RH+¡¢RH-) : Ui : 28VDC; li : 93mA; Pi : 0.65W; Ci : 0.02uF; Li : 0mH

(T+¡¢T-) : Ui : 28VDC; li : 93mA; Pi : 0.65W; Ci : 0.02uF; Li : 0mH
Environment Temperature T4 : -40°C~80°C

T6 : -40°C~60°C

GENERAL INFORMATION

Power Supply 9~28VDC
Maximum Power 0.04UV (W) (UV=supply voltage)
Output Load ≤500Ω
Display Intrinsically safe: Optional LCD display (with unit without backlight)

Dust intrinsically safe: No display
Housing Material ADC12, stainless steel probe and sintered mesh filter
Working Temperature T4: -40°C~80°C

T6: -40°C~60°C, 5%~95%RH (non-condensing)
Protection Class IP65
Weight ≈666g (Wall-mounted)

≈760g (Duct type)

≈813g (Split type, without accereceries)
Certificates CE

Intrinsically Safe Explosion-proof

Dust Intrinsically Safe Explosion-proof

WARNING

1.The product housing is made of aluminium alloy, please avoid the risk of ignition during use due to impact or friction.

2. The housing must be reliably grounded during installation.

3.The product display is made of plastic with a potential danger of electrostatic charge. Please avoid friction during use, or wipe with a wet cloth when cleaning.

4. When the product is used in explosive dust environments, there is a potential danger of electrostatic charge, so it should not be used in areas affected by charge-generating processes, mechanical friction, separation processes, electronic emission and pneumatic transmission of dust.


ACCURACY CURVE CHART



DIMENSIONS

SELECTION GUIDE

1. Example LFH711-A4A4311B represents wall-mounted type, accuracy of ±3% RH (±0.3'C), humidity output 4-20mA, temperature output 4-20mA, temperature range 0 ~ 50'C, with display;

2. When the temperature range is selected as 8, the temperature range specified by the customer shall not exceed the specified range,T6: -40°C~60°C; T4: -40°C~80°C;

3. When the display is selected as showing (1), only intrinsically safe type (B) can be selected.

4. Prolonged exposure of the product's sensor probe to high concentrations of chemical gases may cause the sensor's reading to shift.

Send your message to Excel Test Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Excel Test Sdn Bhd 201701016145 (1230309-H)
Unit C717, 7th Floor, Block C, Kelana Square, 17, Jalan SS 7/26, 47301 Petaling Jaya, Selangor, Malaysia.

Tel:
Fax:

Email:
Website: https://www.etccc.com.my
Website: https://www.etcoldchain.com.my
Website: https://etccc.newpages.com.my/
Website: https://etccc.n.my/

Other Office

Sales & Admin Department
Unit C3A10, 3Ath Floor, Block C, Kelana Square, 17, Jalan SS 7/26, 47301 Petaling Jaya, Selangor, Malaysia.

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us