Please login to use this feature.
      
You can use this feature to add the product to your favourite list.
      
      Close
      
       You have removed this product from your favourite list.
      
      Close
       
      
      
      Please login to use this feature.
      
You can use this feature to add the company to your favourites list.
      
      Close
      
       This company has been removed from your favourite list.
      
      Close
       
      
      
      Please login to use this feature.
      
You can use this feature to add the company to your inquiry cart.
      
      Close
      
       This company has been added to your inquiry cart.
      
      
      Close
       
      
      
       This company has been removed from your inquiry cart.
      
      
      Close
       
      
      
       This product has been added to your inquiry cart.
      
      
      Close
       
      
      
       This product has been removed from your inquiry cart.
      
      
      Close
       
      
      
       Maximum number of Product/Company has been reached in inquiry cart.
      
      
      Close
       
     
     
     
     
     
     
     
     
     
     
     
     
     
     
     
    
    
      
       You have removed this product from your favourite list.      
      
      Close
       
   
 
 
     
    Daily Login Reward
    
    Congratulations! 
You¡¯ve earned your daily login reward for today!
    5 NP PointHere are the reward you¡¯ve earned! 
Check your Daily Login Rewards 
    Be sure to come back everyday for more rewards!
Thanks!
     
    
 
    
      
      Scan and Whatsapp Me
           
            ![qr code]() Note: Some mobile phone default QR scanners cannot scan to open the WhatsApp App directly.
            Cancel
            Note: Some mobile phone default QR scanners cannot scan to open the WhatsApp App directly.
            Cancel
       
   	
 
 
 
             
            
            
            
                        
            
            	
        
        
        
        
        
		
		
		
		
        
                
        	
        
        
        
        
        
       	
        
         
        
         
        
        
        
        			
                    
        			
                    
                     
                    
                    
                    
                    
                    
                    
                    
                    
                    
                    
                    
                    
Selangor,Kuala Lumpur (KL),Petaling Jaya - Supplier Four channel data logger with pulse and two-state inputs
                    
                    
                    
		
         
                     
		 
        
        	
            		  
           
            
             
           
           
            
            
            
            
              
           
            
            09-Feb-2020
            
                
            
               
                
               
            	
                
                
                
	
		
			| 
					Technical data | Value | 
	
	
		
			| Measured value | Two-state signal Pulses
 | 
		
			| BINARY INPUT |  | 
		
			| Parameters of the voltage contact | „L“ level input voltage:< 0,4 V(*); „H“ level input voltage:> 2 V;
 Minimum voltage applicable:0 V;
 Maximum voltage applicable:+30 V DC
 | 
		
			| Parameters of the voltage-free contact | Contact resistance in „switched-on“ state:< 10 kOhm; Contact resistance in the „switched-off“ state:> 300 kOhm;
 Contact voltage in the „switched-off“ state: ca 3 V;
 Minimum state duration necessary for latching the state:1s
 | 
		
			| COUNTER INPUT |  | 
		
			| Counter parameters | Range 24 bits (16 777 215), the possibility of letting the counter overflow | 
		
			| Maximum pulse frequency | configured for voltage input - max. 5kHz configured for a voltage-free or open-collector transistor - max. 200Hz
 | 
		
			| GENERAL TECHNICAL DATA |  | 
		
			| Operating temperature | -20 to +60 °C | 
		
			| Channels | 4x binary input Nebo 2x binary input a 2x counter | 
		
			| Memory | 500,000 values in noncyclic logging mode; 350,000 values in cyclic record mode | 
		
			| Recording interval | adjustable from 1 s to 24 h | 
		
			| Display and alarm refresh | adjustable 1 s, 10 s, 1 min | 
		
			| Recording mode | noncyclic - data logging stops after filling the memory cyclic - after filling memory oldest data is overwritten by new
 | 
		
			| Real-time clock | year, leap year, month, day, hour, minute, second | 
		
			| Power | Lithium battery 3.6V, size AA | 
		
			| Protection class | IP20 | 
		
			| Dimensions | 61 x 93 x 32 mm | 
		
			| Weight (including batteries) | approx. 120 g | 
		