Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Atomic Solutions Sdn Bhd
Atomic Solutions Sdn Bhd 201501005892 (1131223-U)
SSM
60189899965
+60189899965 WeChat QR
WeChat QR

Wechat ID: +60189899965

Social Media Link
  • facebook
  • facebook

31-Mar-2026

PDL-1000 High-Sensitivity Hall Measurement System

High-sensitivity parallel dipole line Hall measurement system for AC and DC field Hall testing of low-mobility, semi-insulating, semiconductor, photovoltaic, and thermoelectric materials.

Product Overview

PDL-1000 is a high-sensitivity parallel dipole line Hall measurement system developed for research and characterization applications where accurate Hall data and low-mobility measurement capability are essential.

The system supports both alternating current (AC) and direct current (DC) field Hall measurement methods using permanent magnets, fully integrated instrumentation, and proprietary software for enhanced research productivity. It is specifically designed to measure a wide range of mobilities, including extremely low mobilities and semi-insulating samples. 

The AC field Hall measurement mode is especially valuable for materials with mobility not exceeding 0.1 cm²/Vs, offering an important advantage over traditional DC field measurement in challenging low-signal applications. Materials in this range are commonly semiconductor, photovoltaic, or thermoelectric materials. 

PDL-1000 is built as a simple, robust tabletop Hall system that uses rotating parallel dipole line magnets instead of bulky electromagnets. The compact design, user-friendly operation, and software-controlled measurement environment make it well suited for advanced materials research, semiconductor characterization, and productivity-focused laboratory workflows.

Key Specifications

  • Measurement ModesAC and DC field Hall measurement
  • SensitivityHandles mobility below 0.1 cm²/Vs
  • Magnetic FieldApproximately 2 T pk-pk
  • Uniformity< 2% standard for 5 × 5 mm sample
  • SoftwareProprietary signal processing and user interface software
  • OptionsWhite light background illumination and gate bias voltage
  • PlatformCompact tabletop design with permanent magnets

Main Features

AC & DC Hall Capability

Measures a wide range of material mobilities, including extremely low mobility and semi-insulating samples, with both AC and traditional DC Hall measurement modes. 

High Sensitivity

Designed for very weak Hall signals, with software-based lock-in detection that helps extract low Hall signal without the need for costly hardware-based lock-in detection. 

Integrated Software & Automation

Provides software-controlled measurement, automated parameter extraction, proprietary signal processing, and a user-friendly interface for improved research efficiency. 

Compact Tabletop Design

Uses rotating parallel dipole line magnets in a simple tabletop setup, eliminating the need for a bulky electromagnet or cooling system. 

The PDL Hall system is capable of both AC and DC Hall measurement modes. Its AC field measurement can be used for materials with mobility not exceeding 0.1 cm²/Vs, which gives it an advantage over DC field measurement for very low-mobility materials and weak Hall signal conditions. 

This makes the PDL-1000 especially suitable for semiconductor, photovoltaic, and thermoelectric materials research, where precise Hall characterization is often required even when standard Hall methods become difficult to apply effectively. 

The compact and robust tabletop design supports straightforward integration into laboratory environments, while the permanent-magnet approach avoids the complexity and space demands typically associated with electromagnet-based Hall systems. 

Benefits

  • Wide Mobility RangeMeasures extremely low mobilities and semi-insulating samples
  • Low Signal ExtractionSoftware-based lock-in detection improves low Hall signal recovery
  • No Bulky ElectromagnetRotating parallel dipole line magnets reduce size and complexity
  • No Cooling NeededNo cooling system necessary for normal operation
  • Automated WorkflowSoftware-controlled measurement and automated parameter extraction
  • Ease of UseUser-friendly operation in a simple and robust tabletop system

Application Focus

Low-Mobility Materials Research

Optimized for Hall measurement of materials with very low mobility, especially where AC field measurement offers better performance than DC methods. 

Semiconductor Characterization

Suitable for semiconductor materials research where high-sensitivity Hall measurement is required for mobility and related electrical property evaluation. 

Photovoltaic & Thermoelectric Materials

Well suited for photovoltaic and thermoelectric materials that fall within low-mobility regimes where sensitive Hall signal extraction is important. 

Efficient Research Productivity

Combines integrated instrumentation, proprietary software, and automated parameter extraction to support faster and more productive Hall measurement workflows. 

System Highlights

The brochure highlights the operation of the magnets and measurement results as core parts of the PDL-1000 system concept, emphasizing how the rotating parallel dipole line design works together with the integrated software environment to support advanced Hall data collection. 

The system is based on patents and technology developed by IBM, reinforcing its positioning as a specialized research instrument for advanced Hall measurement and material characterization applications.

Send your message to Atomic Solutions Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Atomic Solutions Sdn Bhd 201501005892 (1131223-U)
33-01, Jalan Sagu 18, Taman Daya, 81100 Johor Bahru, Johor, Malaysia.

Tel:
Fax:

Email:
Website: https://www.atomic-solutions.net
Website: https://atomic-solutions.net.newpages.com.my/
Website: https://atomic-solutions.net.onesync.my/

Other Office

Kuala Lumpur Branch
21-3, Dataran Mutiara, Jalan 7/4, Taman Serdang Jaya, 43300 Seri Kembangan, Selangor, Malaysia.

Tel:
Fax:
Email:

Penang Branch
8, 1st Floor, Tingkat Bukit Minyak 9, Taman Bukit Minyak, 14000 Bukit Mertajam, Pulau Pinang, Malaysia.

Tel:
Fax:

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us