Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
United Faith Sdn Bhd
United Faith Sdn Bhd 1253020-D
Business
Hours
Monday - Friday 9:00 AM - 5:30 PM
Saturday 9:00 AM - 12:00 PM
Sunday Closed
We′re closed on Public Holiday
Open Closed
Featured Merchant
VISITORS
Social Media Link
  • facebook

24-Mar-2020

General Purpose Controller

Programmable controller for utilizes a library of factory-engineered control programs for fan coils, unit ventilators, water source heat pumps and constant volume AHUs

The AppController continuously monitors and regulates equipment operation with reliability and precision. The AppController’s factory-engineered control programs provide optimum performance and energy efficiency for HVAC equipment such as fan coils, unit ventilators, water source heat pumps, and constant volume AHUs. It also features native BACnet communications and plug-and-play connectivity to the Carrier i-Vu Building Automation System.


carrier-bacnet-international-member

Application Features

  • Library of factory-engineered control programs for fan coils, unit ventilators, water source heat pumps, and constant volume AHUs
  • Supports Snap graphical programming for creating customized control programs
  • Supports Carrier communicating room sensors, which allow for local setpoint adjustment and local overrides

Hardware Features

  • Battery-backed real time-clock keeps time in the event of power failure
  • Stand-alone control of up to 14 I/O points using proven algorithms
  • Native BACnet MS/TP communications

System Benefits

  • Fully plug-and-play with the Carrier i-Vu Building Automation System
  • Supports demand limiting for maximum energy savings
 

Specifications

BACNet Support Advanced application controller (B-AAC), as defined in BACNet 135-2001 Annex L
Communication Ports BACnet port: EIA-485 port for BACnet MS/TP communications (baud rates is DIP switch selectable)
Local Access port: For system start-up and troubleshooting (115.2 kbps)
Rnet port: For connecting Carrier communicating room sensors and Carrier's touchscreen user interface
Inputs 6 inputs: Configurable for thermistor or dry contact. Inputs 1 and 2 are also configurable for 0-5 VDC. Inputs 7 and 8 are not used. AIs have 10 bit A/D resolution.
Outputs 5 binary outputs: Relay contacts rated at 1A max @ 24 VAC/VDC, configured normally open.
3 analog outputs: Rated at 0-10VDC, 5mA max, with 8 bit D/A resolution using filtered PWM.
Protection Incoming power and network connections are protected by non-replaceable internal solidstate polyswitches that reset themselves when the condition that causes a fault returns to normal. The power, network, input, and output connections are also protected against voltage transient and surge events..
Real Time Clock Battery-backed real time clock keeps track of time in event of power failure
Battery 10-year Lithium CR2032 battery provides a minimum of 10,000 hours of trend data & time retention during power outages.
Status Indicators LED status indicators for communications, run status, error, power, and all digital outputs.
Controller Addressing Rotary DIP switches set BACnet MS/TP MAC address of controller.
Listed By UL-916 (PAZX), cUL-916 (PAZX7), FCC Part 15-Subpart B-Class A, CE EN50082-1997
Environmental Operating Range Operating: 0° to 140°F (-18° to 54°C), 10-90% relative humidity, non-condensing
Storage: -24°F to 140°F (-30° to 60°C), 10-90% relative humidity, non-condensing
Power Requirements 24VAC +/- 10%, 50-60Hz
18VA power consumption
26VDC (25V min, 30V max
Single Class 2 source only, 100VA or less
Dimensions Length: 5-5/8” (14.31 cm)
Width: 5-1/8” (13 cm)
Depth: 2” (5.1 cm)
Weight: 0.44 lbs. (0.20 kg)

Send your message to United Faith Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

United Faith Sdn Bhd 1253020-D
6 (Ground Floor), Jalan BPU 6, Bandar Puchong Utama, 47100 Puchong, Selangor, Malaysia.

Tel:

Email:
Website: https://www.unitedfaith.com.my
Website: https://unitedfaith.newpages.com.my/
Website: https://unitedfaith.n.my/

Other Office

SG Branch : United Faith Pte Ltd
7030, Ang Mo Kio Ave 5, #01-23, Northstar@AMK, Singapore 569880.

Tel:

KL Branch
8G, Jalan Pandan 2/3, Pandan Jaya, 55100 Kuala Lumpur, Malaysia.

Tel:

PJ Branch
13, Jalan 21/37, SS 2, 47300 Petaling Jaya, Selangor, Malaysia.

Tel:

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • VN 2378
  • BR 1283
  • US 1123
  • SG 690
  • CN 457
  • GB 318
  • HK 290
  • MX 258
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us