Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
United Faith Sdn Bhd
United Faith Sdn Bhd 1253020-D
Business
Hours
Monday - Friday 9:00 AM - 5:30 PM
Saturday 9:00 AM - 12:00 PM
Sunday Closed
We′re closed on Public Holiday
Open Closed
Featured Merchant
VISITORS
Social Media Link
  • facebook

23-Mar-2020

Line Voltage Standard Models

TB-C, TB-HM-C

Carrier’s ComfortVu™ BACnet thermostats offer local control of a building’s heating, ventilating and air-conditioning (HVAC) system as well as remote control from any BACnet-compliant building management system (BMS), including Carrier’s i-Vu® building automation system.
 

  • Large, backlit LCD display
  • Touchscreen occupant controls
  • Support for Celcius or Fahrenheit
  • BACnet MS/TP port for easy integration with i-Vu system or any BACnet-compliant BMS
  • On-board DIP switches to configure equipment type and sequence of operation
  • 2 universal inputs, 2 analog outputs, and 6 digital outputs
  • Available in two 120/220 Vac models (international only, not UL approved):
    Temperature only (TB-C)
    Temperature/Humidity/PIR Motion (TB-HM-C)

Supported Functions

  • Manage 7-day schedules via the thermostat
  • Manage setpoints, occupancy status, fan speed, and heating/cooling mode via the thermostat or BACnet BMS
  • Support for Title 24 demand response/economizer FDD and IECC2015 economizer FDD when connected to a BMS

Equipment Compatibility

  • Rooftop Units
  • Heat Pumps
  • Fan Coils
  • Exhaust Fans
  • Unit Heaters

Supported Applications (depends on available I/O)

  • Up to 3 stages of heat / 2 stages of cool
  • 2 pipe / 4 pipe cooling / heating valves (0-10V)
  • Up to 3 fan speeds
  • VFD (0-10V)
  • Economizer (open/close)
  • Reversing valve
  • Humidifier (0-10V) / Reheat (dehumidify)
Specifications

Power Requirements 85-240 Vac line voltage: 1.5VA unit, 920 VA full load
Communication BACnet MS/TP with baud rates up to 76.8 kbps, detected and set automatically by the BACnet Thermostat. Max 127 devices.
Real-time Clock Real-time clock keeps track of time in the event of a power failure for up to 7 days
Display Backlit Touchscreen, °F or °C Selectable
Sensing Element Temperature: Range: 41° F to 95° F (5° C to 35° C) Accuracy: ±1.0° F (0.5° C)
Humidity: Range: 10% to 90% Accuracy: ±3.0% typical
Motion Sensing Sensor Type: PIR, quad, omnidirectional
Distance:16.4 feet (5m)
Detection range: (HxV) 90° x 30°
Movement speed: 2.62 to 3.94 ft/s (0.8 to 1.2 m/s)
Detection object:15.75 x 9.84 in. (400 x 250 mm)
Inputs T1, 0 – Normally open or normally closed dry contract, or 0-10 Vdc analog input, or 50 kOhm thermistor @ 25°C
A, B - Communication +/- (RS485)
In1, 0 - Normally open or Normally closed dry contract, or 0-10 Vdc analog input, or 50 kOhm thermistor @ 25°C
C, R - Power: 24 Vac for part numbers TB-24-C and TB-24-HM-C or 110-220 Vac line voltage for part numbers TB-C and TB-HM-C
Outputs 11, 12, 13 – Digital outputs, 3A
14 – Digital outputs 0.3A
15, 16 - Digital Output 0.3A or Analog output 0-10 Vdc, 5 mA max., not isolated
Environmental Operating Range 50° to 122°F (10° to 50°C), 10 to 90% relative humidity, non-condensing
Compliance United States of America: FCC CFR47, Chapter 1, Subchapter A, Part 15, Class B
Canada: Industry Canada Compliant, ICES-003, Class B
Europe: Mark Low Voltage Directive: 2014/35/EU RoHS Compliant: 2011/65/EU
Australia and New Zealand: C-Tick Mark, AS/NZS 61000-6-3
CA Prop 65 Warning: This product can expose you to chemicals including Styrene and 1,3 – Propane sultone, which are known to the State of California to cause cancer. Go to www.p65warnings.ca.gov.

Send your message to United Faith Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

United Faith Sdn Bhd 1253020-D
6 (Ground Floor), Jalan BPU 6, Bandar Puchong Utama, 47100 Puchong, Selangor, Malaysia.

Tel:

Email:
Website: https://www.unitedfaith.com.my
Website: https://unitedfaith.newpages.com.my/
Website: https://unitedfaith.n.my/

Other Office

SG Branch : United Faith Pte Ltd
7030, Ang Mo Kio Ave 5, #01-23, Northstar@AMK, Singapore 569880.

Tel:

KL Branch
8G, Jalan Pandan 2/3, Pandan Jaya, 55100 Kuala Lumpur, Malaysia.

Tel:

PJ Branch
13, Jalan 21/37, SS 2, 47300 Petaling Jaya, Selangor, Malaysia.

Tel:

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • US 16030
  • GB 12397
  • CA 10536
  • AU 9968
  • IE 5219
  • NZ 4062
  • BR 3116
  • CN 1348
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us