Overview
The Edwards Diffstak 160 (ISO160 inlet) design has been proven over many years with thousands of pumps installed.
This pump has a pneumatically actuated high vacuum isolation valve and is supplied with: NW25 elbow, NW25 centering-ring, NW25 clamp, water pipe couplings and ferrules, inlet ISO 160 Co-Seal.
Technical Data
Pumping speed | |
nitrogen | 700 l s-1 |
hydrogen | 1300 l s-1 |
Min backing pump displacement* | 12 m3h-1 |
Recommended backing pump | RV12 or E2M18 |
Recommended fluid | Santovac® 5 |
Fluid charge (dry) | 255 ml |
Inlet connection compatible with | ISO160 |
Backing connection | NW25 |
Cooling water connection | 10 mm compression fittings |
Heater power | 1.35 kW |
Min cooling-water flow at 20°C | 115 l h-1 |
Pneumatic connections† | 6mm coupling x ¼ BSP male stud |
Pneumatic actuating pressure | |
Minimum | 2.4bar / 35psi |
Maximum | 6.9bar / 100psi |
Weight | |
160/700M | 26kg |
160/300P | 27kg |
* For maximum throughput
† 160/700P only