Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
EC Instruments & Engineering Sdn Bhd
EC Instruments & Engineering Sdn Bhd 201401004818 (1080893-P)
Featured Merchant
VISITORS
Social Media Link
  • facebook

20-Jan-2025

Frequency Converter with Trip Values KFU8-UFC-Ex1.D

< 1-channel isolated barrier

< Universal usage at different power supplies

< Input for NAMUR sensors or dry contacts

< Input frequency 1 mHz ... 5 kHz

< Current output 0/4 mA ... 20 mA

< Relay contact and transistor output

< Start-up override

< Line fault detection (LFD)

< Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511

 

Datasheet excerpt: Technical data of  KFU8-UFC-Ex1.D

General specifications

Signal type

Digital Input

Functional safety related parameters

Safety Integrity Level (SIL)

SIL 2

Supply

Connection

terminals 23, 24

Rated voltage

20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz

Power dissipation/power consumption

≤ 2 W ; 2.5 VA / 2.2 W ; 3 VA

Interface

Programming interface

programming socket

Input

Connection side

field side

Connection

Input I: intrinsically safe: terminals 1+, 3-
Input II: non-intrinsically safe: terminals 13+, 14-

Input I

sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact

 

Pulse duration

> 50 µs

 

Input frequency

0.001 ... 5000 Hz

 

Line fault detection

breakage I ≤ 0.15 mA; short-circuit I > 6.5 mA

Input II

startup override: 1 ... 1000 s, adjustable in steps of 1 s

 

Active/Passive

I > 4 mA (for min. 100 ms) / I < 1.5 mA

 

Open circuit voltage/short-circuit current

18 V / 5 mA

Output

Connection side

control side

Connection

output I: terminals 10, 11, 12
output II: terminals 16, 17, 18
outout III: terminasl 19+, 20-
output IV: terminals 8+, 7-

Output I, II

signal, relay

 

Contact loading

250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A

 

Mechanical life

5 x 107 switching cycles

 

Energized/De-energized delay

approx. 20 ms / approx. 20 ms

Output III

electronic output, passive

 

Contact loading

40 V DC

 

Signal level

1-signal: (L+) - 2.5 V (50 mA, short-circuit/overload proof)
0-signal: switched off (off-state current ≤ 10 µA)

Output IV

analog

 

Current range

0 ... 20 mA or 4 ... 20 mA

 

Open loop voltage

max. 24 V DC

 

Load

max. 650 Ω

 

Fault signal

downscale I ≤ 3.6 mA , upscale ≥ 21.5 mA (acc. NAMUR NE43)

Transfer characteristics

Input I

 

 

Measuring range

0.001 ... 5000 Hz

 

Resolution

0.1 % of the measurement value , ≥ 0.001 Hz

 

Accuracy

0.1 % of the measurement value , > 0.001 Hz

 

Measuring time

< 100 ms

 

Influence of ambient temperature

0.003 %/K (30 ppm)

Output I, II

 

 

Response delay

≤ 200 ms

Output IV

 

 

Resolution

< 10 µA

 

Accuracy

< 20 µA

 

Influence of ambient temperature

0.005 %/K (50 ppm)

Galvanic isolation

Input I/other circuits

reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output I, II/other circuits

reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Mutual output I, II, III

reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output III/power supply

reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Output III/start-up override

basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff

Output III/IV

basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff

Output IV/power supply

reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Start-up override/power supply

reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Interface/power supply

reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff

Interface/output III

basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff

Indicators/settings

Display elements

LEDs , display

Control elements

Control panel

Configuration

via operating buttons
via PACTware

Labeling

space for labeling at the front

Directive conformity

Electromagnetic compatibility

 

 

Directive 2014/30/EU

EN 61326-1:2013 (industrial locations)

Low voltage

 

 

Directive 2014/35/EU

EN 61010-1:2010

Conformity

Electromagnetic compatibility

NE 21:2006

Degree of protection

IEC 60529:2001

Input

EN 60947-5-6:2000

Ambient conditions

Ambient temperature

-20 ... 60 °C (-4 ... 140 °F)

Mechanical specifications

Degree of protection

IP20

Connection

screw terminals

Mass

300 g

Dimensions

40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2

 

Height

119 mm

 

Width

40 mm

 

Depth

115 mm

Mounting

on 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificate

TÜV 99 ATEX 1471

 

Marking

Ex-Hexagon II (1)G [Ex ia Ga] IIC
Ex-Hexagon II (1)D [Ex ia Da] IIIC
Ex-Hexagon I (M1) [Ex ia Ma] I

Supply

 

 

Maximum safe voltage

253 V AC / 125 V DC (Attention! Um is no rated voltage.)

Input I

terminals 1+, 3-: Ex ia

 

Voltage Uo

10.1 V

 

Current Io

13.5 mA

 

Power Po

34 mW (linear characteristic)

Input II

terminals 13+, 14- non-intrinsically safe

 

Maximum safe voltage Um

40 V (Attention! The rated voltage can be lower.)

Output I, II

terminals 10, 11, 12; 16, 17, 18 non-intrinsically safe

 

Maximum safe voltage

253 V (Attention! The rated voltage can be lower.)

 

Contact loading

253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load (TÜV 99 ATEX 1471)

Output III

terminals 19+, 20- non-intrinsically safe

 

Maximum safe voltage Um

40 V (Attention! Um is no rated voltage.)

Output IV

terminals 8+, 7- non-intrinsically safe

 

Maximum safe voltage

40 V DC (Attention! Um is no rated voltage.)

Interface

RS 232

 

Maximum safe voltage

40 V (Attention! Um is no rated voltage.)

Galvanic isolation

 

 

Input I/other circuits

safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V

Directive conformity

 

 

Directive 2014/34/EU

EN IEC 60079-0:2018 , EN 60079-11:2012

International approvals

FM approval

 

 

Control drawing

16-538FM-12

IECEx approval

 

 

IECEx certificate

IECEx TUN 04.0007

 

IECEx marking

[Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I

General information

Supplementary information

Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

 

Send your message to EC Instruments & Engineering Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

EC Instruments & Engineering Sdn Bhd 201401004818 (1080893-P)
46, Jalan Seri Austin 3/55, Taman Seri Austin, 81100 Johor Bahru, Johor, Malaysia.

Tel:

Email:
Website: https://www.ecinstruments.net
Website: https://ecinstruments.newpages.com.my/
Website: https://ecinstruments.n.my/

Other Office

[Singapore Office] EC Instruments & Engineering Pte Ltd
6, Penjuru Place, #01-31,2-8 Penjuru Tech Hub, Singapore 608781.

Tel:
Fax:
Email:

[Ipoh Office] EC Instruments & Engineering Sdn Bhd
29, Laluan Bg Perdana 20, Taman Batu Gajah Perdana, 31550 Pusing, Perak, Malaysia.

Tel:
Email:

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • US 13790
  • GB 11496
  • AU 9677
  • CA 9454
  • IE 5547
  • NZ 4821
  • BR 2819
  • SG 1380
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us