Technical data of UC2000-30GM70-2E2R2-V15
General Specifications| Sensing range | 100 ... 2000 mm | |
| Adjustment range | 150 ... 2000 mm | |
| Dead band | 0 ... 100 mm | |
| Standard target plate | 100 mm x 100 mm | |
| Transducer frequency | approx. 200 kHz | |
| Response delay | ≤ 100 ms | 
Electrical Specifications
| Rated operating voltage | Ue | 24 V DC | 
| Operating voltage | UB | 12 ... 30 V DC (including ripple) | 
| Ripple | ≤ 10 % | |
| No-load supply current | I0 | ≤ 50 mA | 
- 2 switch outputs
- Synchronization options
- Temperature compensation
- Can be parameterized via the ULTRA-PROG-IR software and interface (accessories)









 
            
             
        
        
        
            
		