Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
EC Instruments & Engineering Sdn Bhd
EC Instruments & Engineering Sdn Bhd 201401004818 (1080893-P)
Featured Merchant
VISITORS
Social Media Link
  • facebook

19-Feb-2025

Redundant Power Feed Module KFD2-EB2.R4A.B

 
  • Interface for Power Rail
  • Used for redundant configuration
  • Supply current ≤ 4 A
  • Replaceable fuse
  • Relay contact output, reversible
  • LED status indication


    Datasheet excerpt: Technical data of  KCD2-SR-Ex1.LB

    General specifications
    Signal type Digital Input
    Functional safety related parameters
    Safety Integrity Level (SIL) SIL 2
    Systematic capability (SC) SC 3
    Supply
    Connection Power Rail or terminals 9+, 10-
    Rated voltage 19 ... 30 V DC
    Ripple ≤ 10 %
    Rated current ≤ 37 mA
    Power dissipation ≤ 750 mW
    Power consumption ≤ 750 mW
    Input
    Connection side field side
    Connection terminals 1+, 2-
    Rated values acc. to EN 60947-5-6 (NAMUR)
    Open circuit voltage/short-circuit current approx. 8 V DC / approx. 8 mA
    Switching point/switching hysteresis 1.2 ... 2.1 mA / approx. 0.2 mA
    Line fault detection breakage I ≤ 0.1 mA , short-circuit I ≥ 6.5 mA
    Pulse/Pause ratio min. 20 ms / min. 20 ms
    Output
    Connection side control side
    Connection output I: terminals 5, 6 ; output II: terminals 7, 8
    Output I signal ; relay
    Output II signal or fault message ; relay
    Contact loading 250 V AC/2 A/cos φ > 0.75; 126.5 V AC/4 A/cos φ > 0.75; 30 V DC/2 A resistive load
    Minimum switch current 2 mA / 24 V DC
    Energized/De-energized delay ≤ 20 ms / ≤ 20 ms
    Mechanical life 107 switching cycles
    Transfer characteristics
    Switching frequency ≤ 10 Hz
    Galvanic isolation
    Input/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
    Input/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
    Output/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
    Output/Output reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
    Indicators/settings
    Display elements LEDs
    Control elements DIP switch
    Configuration via DIP switches
    Labeling space for labeling at the front
    Directive conformity
    Electromagnetic compatibility  
      Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
    Low voltage  
      Directive 2014/35/EU EN 61010-1:2010+A1:2019+A1:2019/AC:2019
    Conformity
    Electromagnetic compatibility NE 21:2017 , EN 61326-3-1:2017 , EN IEC 61326-3-2:2018
    Degree of protection IEC 60529:1989+A1:1999+A2:2013
    Functional safety IEC/EN 61508:2010
    Input EN 60947-5-6:2000
    Ambient conditions
    Ambient temperature -40 ... 70 °C (-40 ... 158 °F)
    Mechanical specifications
    Degree of protection IP20
    Connection screw terminals
    Mass approx. 100 g
    Dimensions 12.5 x 119 x 114 mm (0.5 x 4.7 x 4.5 inch) (W x H x D) , housing type A2
      Height 119 mm
      Width 12.5 mm
      Depth 114 mm
    Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
    Data for application in connection with hazardous areas
    EU-type examination certificate BASEEFA 06 ATEX 0092 X
      Marking Ex-Hexagon II 3(1)G Ex ec nC [ia Ga] IIC T4 Gc , Ex-Hexagon II (1)D [Ex ia Da] IIIC , Ex-Hexagon I (M1) [Ex ia Ma] I
      Input Ex ia
      Voltage 10.5 V
      Current 13 mA
      Power 34 mW (linear characteristic)
    Supply  
      Maximum safe voltage 253 V AC (Attention! Um is no rated voltage.)
    Output  
      Contact loading Zone 2 : 50 V AC/2 A/cos φ > 0.75; 30 V DC/2 A resistive load
      Maximum safe voltage 253 V AC (Attention! The rated voltage can be lower.)
    Fault indication output  
      Maximum safe voltage 40 V DC (Attention! Um is no rated voltage.)
    Galvanic isolation  
      Input/Output safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
      Input/power supply safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
    Directive conformity  
      Directive 2014/34/EU EN IEC 60079-0:2018 , EN 60079-7:2015+A1:2018 , EN 60079-11:2012 , EN IEC 60079-15:2019
    International approvals
    UL approval E106378
      Control drawing 116-0477 (cULus)
    IECEx approval  
      IECEx certificate IECEx BAS 06.0025 X
      IECEx marking Ex ec nC [ia Ga] IIC T4 Gc
    [Ex ia Da] IIIC
    [Ex ia Ma] I
    General information
    Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Send your message to EC Instruments & Engineering Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

EC Instruments & Engineering Sdn Bhd 201401004818 (1080893-P)
46, Jalan Seri Austin 3/55, Taman Seri Austin, 81100 Johor Bahru, Johor, Malaysia.

Tel:

Email:
Website: https://www.ecinstruments.net
Website: https://ecinstruments.newpages.com.my/
Website: https://ecinstruments.n.my/

Other Office

[Singapore Office] EC Instruments & Engineering Pte Ltd
6, Penjuru Place, #01-31,2-8 Penjuru Tech Hub, Singapore 608781.

Tel:
Fax:
Email:

[Ipoh Office] EC Instruments & Engineering Sdn Bhd
29, Laluan Bg Perdana 20, Taman Batu Gajah Perdana, 31550 Pusing, Perak, Malaysia.

Tel:
Email:

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • US 18192
  • GB 13575
  • BR 12119
  • CA 10587
  • AU 9164
  • IE 5940
  • NZ 1804
  • TR 1258
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us