Key Features
- Intrinsically safe with European and Indian approval
- Includes external charge amplifier
- Optional temperature ranges
- Low noise cable
- Compression Crystal Construction
Industries
Building services, Pulp and Paper, Mining, Metals, Utilities, Automotive, Water, Pharmaceutical
Applications
Fans, Motors, Pumps, Compressors, Centrifuges, Conveyors, Air Handlers, Gearboxes, Rolls, Dryers, Presses, Cooling, VAC, Spindles, Machine Tooling, Process Equipment
| Operating Temperature Range |
Ex ia IIC T2 (-20°C ≤ Ta ≤ +250°C) Accelerometer, Ex ia IIC T4 (-20°C ≤ Ta ≤ +80°C) Charge Amplifier |
|---|---|
| Sealing |
IP65 |
| EMC |
EN61326-1:2013 |
| Case Material |
Stainless Steel |
| Sensing Element/Construction |
PZT/Compression |
| Weight |
125gms/ 4.4 oz (nominal) |
| Top/Side Entry |
Side Entry |
| Design |
Standard |
| Feature |
High Temperature, Intrinsically Safe |
| Connector/Cable Type |
Low Noise Cable |
| Output |
Single Output |
| Axis |
Single (Standard) |




BR 31554
VN 15250
US 7400
AR 5488
MX 3982
CN 3515
IQ 2751
GB 2315