Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Obsnap Instruments Sdn Bhd
Obsnap Instruments Sdn Bhd 599642-A
Business
Hours
Monday - Friday 8:30 AM - 5:30 PM
Saturday 8:30 AM - 12:30 PM
Sunday Closed
Get the latest
Obsnap Instruments Sdn Bhd
App for Android
Open Closed
Featured Merchant
VISITORS
Social Media Link
  • wordpress
  • blogger

03-Dec-2015

The HI93414 is a high accuracy Turbidity and Chlorine Portable Meter. This meter is a combination of a nephelometer and photometer to measure the most important parameters in drinking water: turbidity and chlorine. The meter is supplied complete with AMCO-AEPA-1 primary turbidity standards and NIST traceable secondary chlorine standards used for calibration and performance verification. The HI93414 meets and exceeds the requirements of EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B for turbidity measurements.The chlorine measurements are are adapted EPA Method 330.5 and Standard Method 4500-Cl G.
  • Fast Tracker™ - Tag Identification System (T.I.S)
  • USB for data transfer
  • Operates on batteries or line voltage
Details

The HI93414 is a multiparameter instrument that measures the most important parameters in drinking water: turbidity and chlorine. The instrument is based on a state-of-the-art optical system which provides accurate results by minimizing stray light and color interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the tungsten lamp. The colorimeter portion of the meter uses a 525 nm narrow band interference filter for maintaining the proper wavelength in the measurement of free and total chlorine. All measurements are performed with 25 mm round cuvettes composed of special optical glass to ensure maximum repeatability of turbidity and chlorine measurements.

Features at-a-glance:

Three Measurement Modes - The HI93414 features three options for measurement including ratio mode for turbidity, free chlorine, and total chlorine. Turbidity measurements can be made in the 0.00 to 1000 NTU (Nephelometric Turbidity Units) range, while free or total chlorine measurements can be made in the 0.00 to 5.00 mg/L (ppm) range.

Multiple reading modes - Normal measurement, continuous measurement, or signal averaging measurement are reading modes available

EPA Compliant -  The HI93414 meets and exceeds the requirements of EPA and Standard Methods both for turbidity and colorimetric chlorine measurements. When the meter is in EPA mode all turbidity readings are rounded accordingly to meet reporting requirements.

Calibration - A two, three, or four-point turbidity calibration can be performed by using the supplied (<0.1, 15, 100, and 750 NTU) standards. Calibration points can be modified if user-prepared standards are used. For free and total chlorine, the 1.00 mg/L (ppm) CAL Check standard can be used for calibration and performance verification.

AMCO AEPA-1 Primary Turbidity Standard - The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.

CAL Check  – With the powerful CAL Check function, reliable performance of the chlorine colorimeter can be validated at any moment by using the exclusive HANNA ready-made, NIST traceable standards.  All standards are supplied with a Certificate of Analysis (COA) for traceability.

Fast Tracker  - For advanced ˜field applications, the HI93414 is equipped with Fast Tracker - Tag Identi˜fication System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker allows users to record the time and location of a speci˜fic measurement or series of measurements using iButton® tags near sampling points for quick and easy readings. Each iButton® tag contains a computer chip with a unique identi˜cation code encased in stainless steel.

GLP Data – The HI93414 features complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. Data includes calibration points, date, and time.

Data Logging – Up to 200 measurements can be stored in the internal memory and recalled at any time.

Data Transfer – For further storage or analysis options, logged data can be downloaded to a Windows compatible PC using the RS232 or USB ports and the HI92000 software.

Backlit Display – A backlit LCD display provides an easy to understand, user-friendly interface. Displayed codes guide the user step-by-step through routine operation and calibration.

Turbidity Specifications

Range 0.00 to 9.99; 10.0 to 99.9; 100 to 1000 NTU
Resolution 0.01; 0.1; 1 NTU
Range Selection automatic
Accuracy ±2% of reading plus 0.02 NTU
Repeatability ±1% of reading or 0.02 NTU, whichever is greater
Stray Light < 0.02 NTU
Light Detector silicon photocell
Method ratio nephelometric method (90° & 180°)
Measuring Mode normal, average, continuous
Turbidity Standards < 0.1, 15, 100, and 750 NTU
Calibration two, three, or four-point calibration

Free and Total Chlorine Specifications

Free and Total Chlorine Range 0.00 to 5.00 mg/L (ppm)
Free and Total Chlorine Resolution 0.01 mg/L (ppm) from 0.00 to 3.50 mg/L (ppm); 0.10 above 3.50 mg/L (ppm)
Free and Total Chlorine Accuracy ±0.02 mg/L @ 1.00 mg/L
Light Detector silicon photocell with 525 nm narrow band interference filter
Method adaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G.
Standards 1.00 mg/L (ppm) free chlorine; 1.00 mg/L (ppm) total chlorine
Calibration one-point calibration

General Specifications

Light Source tungsten filament lamp / greater than 100,000 readings
Display 40 x 70 mm graphic LCD (64 x 128 pixels) with backlight
Log Memory 200 records
Connectivity USB or RS232
Environment 0 to 50°C (32 to 122°F), RH max 95% non-condensing
Power Supply 1.5V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use
Dimensions 224 x 87 x 77 mm (8.8 x 3.4 x 3.0”)
Weight 512 g (18 oz.)
Ordering Information HI93414 is supplied with sample cuvettes and caps (5), HI98703-11 calibration cuvettes for turbidity, HI93414-11 calibration cuvettes for chlorine, silicone oil, cuvette wiping cloth, scissors, batteries, AC adapter, instruction manual, and rugged carrying case.
Warranty 2 years

 

Send your message to Obsnap Instruments Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Obsnap Instruments Sdn Bhd 599642-A
29A, Jalan SS 15/4C, 47500 Subang Jaya, Selangor, Malaysia.

Tel:
H/p:
Fax:

Email:
Website: http://www.obsnapinstrument.com
Website: https://obsnapinstrument.newpages.com.my/
Website: https://obsnapinstrument.n.my/

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • US 8091
  • GB 7796
  • CA 7091
  • AU 6775
  • IE 4357
  • BR 3853
  • NZ 1404
  • VN 684
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us