Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Obsnap Instruments Sdn Bhd
Obsnap Instruments Sdn Bhd 599642-A
Business
Hours
Monday - Friday 8:30 AM - 5:30 PM
Saturday 8:30 AM - 12:30 PM
Sunday Closed
Get the latest
Obsnap Instruments Sdn Bhd
App for Android
Open Closed
Featured Merchant
VISITORS
Social Media Link
  • wordpress
  • blogger

24-Nov-2015

Product Features
  • True RMS on ACV and ACA measurment.
  • 3 - 3/4 Digital LCD with bar-graph.
  • Water - Proof ABS housing.
  • Auto - Ranging on Volt , Ohm , Frequency,
    and Capacitancd measurements.
  • Auto - power off.
  • Also provides MAX / MIN recording ; MEM and READ ;
    REL and data HOLD mode.
  • Ohms , Diode Audible continuity , Capacitance input
    Overload protection to 600Vrms.
  • 20A 600V high energy fuse protection on 20A AC/DC.
  • Flip - up stand.
Specification

Electrical Specifications :

q DC  Voltage(Autorange & Manual range)

Range Resolution Accuracy Overload protection Burden voltage
400mV 100 uV ±(0.5rdg+1dgt) 100MΩ DC 1100V
AC 800V
      4V   1 mV 11MΩ
    40V 10 mV 10MΩ
  400V 100 mV
1000V       1V
q DC  Current( Manual  range )
Range Resolution Accuracy Input Impedance Overload protection
4mA 1 uA ±( 1%rdg+1dgt ) 0.5A / 250 V
fuse
0.45V
40mA 10 uA
400mA 100 uA 0.65V
20A 10 mA ±( 1.5%rdg +2dgts ) 20A / 600V
high energy fuse
1.3V
q AC  VoltageAutorange ManualTrue RMS
Range Resolution Accuracy Input impedance Overload protection Frequency
Response
400mV 100uV ±( 1.2 rdg + 5dgts) 100MΩ DC 1100V
AC 800V
5060 HZ
      4V    1mV 11MΩ 40450 Hz
    40V 10mV 10MΩ
  400V      100mV
750V      1V ±( 1.5 rdg + 5dgts)
  ※ 400mV only manual range.
q AC  Current( Manual range )TRUE RMS

Range Resolution Accuracy Overload protection Burden    Voltage Frequency
Response
4mA   1uA ±( 1.5 rdg
+ 5dgts)
0.5A / 250V
fuse
0.45V 40450 Hz
40mA 10uA
400mA 100uA 0.65V
20A 10mA ±( 2 rdg + 5dgts) 20A / 600 high energy fuse 1.3V
  ※Conversion  type : AC  coupled , TRMS measurement .
q Addition  Crest  Factor  Eeeors  ( non - sinecure ) ACA / ACV

Crest   Factor Error ( % of reading )
 1  -  3 1%
3  -  5 4.5%
※ [ For frequencies at 50 / 60 Hz , slow AC filter specified  for sinecurve  input  only . ]
※Response time : 5  seconds  max , to rated accuracy in the selected  range .
qFrequency ( Hz )(Autorange)

Range Resolution Accuracy Sensitivity
   100 Hz   0.01Hz ±( 0.1rdg+2dgts) 100m V / 1V / 10V
( By Range Button selector )
      1KHz     0. 1Hz
    10KHz         1Hz
  100KHz       10Hz
 500KHz     100Hz

qResistance ( Ω )(Autorange & Manual  range)
Range Resolution Accuracy Open circuit
Voltage
Overload protection
   400Ω 100mΩ ±(0.75rdg+3dgts) 0.5 VDC 600Vrms
    4KΩ 1Ω
  40KΩ 10Ω
400KΩ 100Ω
   4MΩ 1KΩ
  40MΩ 10KΩ ±( 1.5 rdg+5dgts)
 
q Audible  continuity
Range Resolution Open Circuit      voltage Continuity  Beeper Overload   Protection
  0.1Ω 0.5 V Approx .40Ω 600 Vrms
 
q Diode  test
Range Resolution Short Circuit  Current Accuracy Open Circuit Voltage Overload Protection
  1mV 0.8mA typical ±( 1%rdg +2dgts ) 3 V 600 Vrms
qADP
Function Input Resolution Accuracy Overload Protection
ADP 400mVDC Full  Scale 1 Count / 0.1mV ± 0.5%rdg
±2LSD
600 Vrms
 
qCapacitance : ( Autoranging & Manul range )

Range Resolution Accurary
4nF 1pF ±( 1.5% rdg + 20 dgts )
40nF 10pF
400nF 100pF ±( 1.5% rdg + 10 dgts )
4uF 1nF
40uF 10nF
 
General Specifications :

  Range  Selection         : All ranges are measured by a single range 
                                           switch operation.
  Low Battery  Indication       : The is displayed  when the battery
                                           voltage drops below the operating voltage.
  Sampling  Rate           : 20 times/sec of  Bargraph indication
                                           2 times/sec of igital display.
  Power  Source            : 2pcs of “ AA ” 1.5V Battery.
  Battery  Life               : 400hr approx.
  Auto  power  off  time     : Approx. 30 minutes.
  Operating  Temperature   : 0 to 40  (32 to 104)  and  Humidity  RH below 80%.
  Storage  Temperature    : -10 to 60 (14 to 140)  and  Humidity        RH below 70 .
  Dimensions , Weight     : 184(L) x 82(W) x 42(H) mm , Approx. 375g.
  Accessories                   : Test  leads . Spare  fuse  0.5A/250V   
                                                                    Battery , Instruction  manual .
Send your message to Obsnap Instruments Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Obsnap Instruments Sdn Bhd 599642-A
29A, Jalan SS 15/4C, 47500 Subang Jaya, Selangor, Malaysia.

Tel:
H/p:
Fax:

Email:
Website: http://www.obsnapinstrument.com
Website: https://obsnapinstrument.newpages.com.my/
Website: https://obsnapinstrument.n.my/

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us