- Tmax 450 °C, 650 °C, or 850 °C
- Stainless steel air-baffles in the furnace for optimum air circulation
- Swing door hinged on the right side
- Base frame included in the delivery, N 15/65 HA designed as table-top model
- Horizontal air circulation
- Temperature uniformity up to +/- 5 °C according to DIN 17052-1 (model N 15/65 HA up to +/- 7 °C)
- Optimum air distribution enabled by high flow speeds
- One removable tray and rails for two additional trays included in the scope of delivery (N 15/65 HA without removable tray)
- Defined application within the constraints of the operating instructions
- NTLog Basic for Nabertherm Controller: Recording of process data with USB-flash drive (NA 30/45 - N 675/85 HA)
Additional equipment (not for model N 15/65HA)
- Optimization of the temperature uniformity up to +/- 3 °C according to DIN 17052-1
- Fan cooling to accelerate the cooling process
- Motor driven exhaust air flaps
- Manual lift door (up to model N(A) 250/.. (HA))
- Pneumatic lift door
- Adjustable air circulation for sensitive components
- Additional removable trays
- Roller conveyor in furnace chamber for heavy charges
- Designed for Tmax 950 °C
- Debinding packages with safety concept starting from 120 liters volume, see page 6 - 8
- Process control and documentation via VCD software package or Nabertherm Control Center (NCC) for monitoring, documentation and control
Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions in mm | Heating | Electrical | Weight | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
°C | w | d | h | in l | W | D | H | power in kW2 | connection | in kg | |
NA 30/45 | 450 | 290 | 420 | 260 | 30 | 1040 | 1290 | 1385 | 3.0 | 1-phase | 195 |
NA 60/45 | 450 | 350 | 500 | 350 | 60 | 1100 | 1370 | 1475 | 6.0 | 3-phase | 240 |
NA 120/45 | 450 | 450 | 600 | 450 | 120 | 1200 | 1470 | 1575 | 9.0 | 3-phase | 310 |
NA 250/45 | 450 | 600 | 750 | 600 | 250 | 1350 | 1650 | 1725 | 12.0 | 3-phase | 610 |
NA 500/45 | 450 | 750 | 1000 | 750 | 500 | 1500 | 1850 | 1800 | 18.0 | 3-phase | 1030 |
NA 675/45 | 450 | 750 | 1200 | 750 | 675 | 1500 | 2050 | 1800 | 24.0 | 3-phase | 1350 |
N 15/65 HA | 650 | 295 | 340 | 170 | 15 | 470 | 845 | 460 | 2.4 | 1-phase | 55 |
N 30/65 HA | 650 | 290 | 420 | 260 | 30 | 607 + 255 | 1175 | 1315 | 5.5 | 3-phase | 195 |
N 60/65 HA | 650 | 350 | 500 | 350 | 60 | 667 + 255 | 1250 | 1400 | 9.0 | 3-phase | 240 |
N 120/65 HA | 650 | 450 | 600 | 450 | 120 | 767 + 255 | 1350 | 1500 | 13.0 | 3-phase | 310 |
N 250/65 HA | 650 | 600 | 750 | 600 | 250 | 1002 + 255 | 1636 | 1860 | 20.0 | 3-phase | 610 |
N 500/65 HA | 650 | 750 | 1000 | 750 | 500 | 1152 + 255 | 1886 | 2010 | 30.0 | 3-phase | 1030 |
N 675/65 HA | 650 | 750 | 1200 | 750 | 675 | 1152 + 255 | 2100 | 2010 | 30.0 | 3-phase | 1350 |
N 30/85 HA | 850 | 290 | 420 | 260 | 30 | 607 + 255 | 1175 | 1315 | 5.5 | 3-phase | 195 |
N 60/85 HA | 850 | 350 | 500 | 350 | 60 | 667 + 255 | 1250 | 1400 | 9.0 | 3-phase | 240 |
N 120/85 HA | 850 | 450 | 600 | 450 | 120 | 767 + 255 | 1350 | 1500 | 13.0 | 3-phase | 310 |
N 250/85 HA | 850 | 600 | 750 | 600 | 250 | 1002 + 255 | 1636 | 1860 | 20.0 | 3-phase | 610 |
N 500/85 HA | 850 | 750 | 1000 | 750 | 500 | 1152 + 255 | 1886 | 2010 | 30.0 | 3-phase | 1030 |