- All-in-one design minimize operating and maintenance costs
- Digital and analog interfaces make for easy, flexible integration.
| Wind Speed | |
| Measurement Range | 0 ... 45m/s |
| Accuracy | ±0.3 m/s or 3% of reading, whichever is greater |
| Resolution | 0.1m/s |
| Wind Direction | |
| Measurement Range | 0 … 359.9° |
| Accuracy | ±3° |
| Resolution | 0.1° |
| Barometric Pressure | |
| Measurement Range | 10 ... 1100hpa |
| Accuracy | ±0.5hpa |
| Resolution | 0.1hpa |
| Air Temperature | |
| Measurement Range | -40 … £«80¡æ |
| Accuracy | ±0.5¡æ |
| Resolution | 0.1¡æ |
| Relative Humidity | |
| Measurement Range | 0 … 100% RH |
| Accuracy | ±3% RH |
| Resolution | 0.1% RH |
| Rain Fall | |
| Measurement Range | 0 … 400 mm/h |
| Accuracy | ±5% |
| Resolution | 0.1mm/h |