Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Pacific Radio (M) Sdn Bhd
Pacific Radio (M) Sdn Bhd 197301002913 (16370-U)
Business Nature:

Distributor Retailer Supplier

Selangor - Fluke 116 / 323 HVAC Combo Kit - Includes Multimeter and Clamp Meter

07-Aug-2015

Fluke 116 / 323 HVAC Combo Kit - Includes Multimeter and Clamp Meter Fluke 116 / 323 HVAC Combo Kit - Includes Multimeter and Clamp Meter Fluke 116 / 323 HVAC Combo Kit - Includes Multimeter and Clamp Meter

Tags:
-
Product Viewed 376

Fluke 116 HVAC Multimeter with Temperature and Microamps


Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating Temperature -10 °C to + 50 °C
Storage Temperature -40 °C to + 60 °C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life 400 hours typical, without backlight

Accuracy Specifications
DC millivolts Range 600.0 mV
Resolution 0.1 mV
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/Resolution 6.000 V / 0.001 V
Range/Resolution 60.00 V / 0.01 V
Range/Resolution 600.00 V / 0.1 V
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Auto volts Range 600.0 V
Resolution 0.1 V
Accuracy 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms Range 600.0 mV
Resolution 0.1 mV
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms Range/Resolution 6.000 V / 0.001 V
Range/Resolution 60.00 V / 0.01 V
Range/Resolution 600.0 V / 0.1 V
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity Range 600 Ω
Resolution 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms Range/Resolution 600.0 Ω / 0.1 Ω
Range/Resolution 6.000 kΩ / 0.001 kΩ
Range/Resolution 60.00 kΩ / 0.01 kΩ
Range/Resolution 600.0 kΩ / 0.1 kΩ
Range/Resolution 6.000 MΩ / 0.001 MΩ
Accuracy 0.9 % + 1
Range/Resolution 40.00 MΩ / 0.01 MΩ
Accuracy 1.5 % + 2
Diode Test Range/Resolution  2.000 V / 0.001 V
Accuracy  0.9% + 2
Capacitance Range/Resolution 1000 nF / 1 nF
Range/Resolution 10.00 μF / 0.01 μF
Range/Resolution 100.0 μF / 0.1 μF
Range/Resolution 9999 μF / 1 μF
Range/Resolution 100 μF to 1000 μF
Accuracy 1.9% + 2
Range/Resolution > 1000 μF
Accuracy 5% + 20%
LoZ capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
Temperature2 (Type-K thermocouple) Range/Resolution -40 °C to 400 °C / 0.1 °C
Accuracy 1% + 102
Range/Resolution -40 °F to 752 °F / 0.2 °F
Accuracy 1% + 182
AC μamps true-rms (45 Hz to 500 Hz) Range/Resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
DC μamps Range/Resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
Hz (V or A input)2 Range/Resolution 99.99 Hz / 0.01 Hz
Range/Resolution 999.99 Hz / 0.1 Hz
Range/Resolution 9.999 Hz / 0.001 Hz
Range/Resolution 50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F


Mechanical & General Specifications
Size 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight 550 g
Warranty 3 years

Fluke 323 True-rms Clamp Meter


Specifications
AC current Range 400.0 A  
Accuracy 2 % ± 5 digits
(45 Hz to 65 Hz)
2.5 % ± 5 digits
(65 Hz to 400 Hz)
AC voltage Range 600.0 V
Accuracy 1.5 % ± 5 digits
DC voltage Range 600.0 V
Accuracy 1.0 % ± 5 digits
Resistance Range 400.0 Ω/ 4000 Ω
Accuracy 1.0 % ± 5 digits
Continuity ≤ 70 Ω
AC response True-rms
Data hold Yes
Size H x W x D (mm) 207 x 75 x 34
Max wire diameter 30 mm (600 MCM)
Weight 265 g
Category rating CAT III 600 V
CAT IV 300 V
Warranty Two-year
 

Model Name Description
Fluke 116/323 Kit Includes: 
  • Fluke 116 HVAC Multimeter with Temperature and Microamps
  • Fluke 323 True-rms Clamp Meter

Test Leads
TL225 TL225 SureGrip™ Stray Voltage Adapter Test Lead Kit
 

 

Send your message to Pacific Radio (M) Sdn Bhd
Thank you for your inquiry!
Our Customer Support will be in touch with you shortly.
Your Name *
Your Company Name
Your Email *
Your Contact Number *
Subject *
Message *
Captcha *
Main Office

Pacific Radio (M) Sdn Bhd 197301002913 (16370-U)
80, Jalan Pasar, Pudu, 55100 Kuala Lumpur, Malaysia.

Tel:
Fax:

Email:
Website: https://www.pacificradio.com.my
Website: https://pacificradio.newpages.com.my/
Website: https://pacificradio.onesync.my/

Other Office

Pacific Electronics (S) Pte Ltd (Head Office)
1 Rochor Canal Road, #01-10/11/12, Sim Lim Square, Singapore 188504.

Tel:
Fax:
Email:

Browse by : Home - Classifieds - Companies - Location - Tags - Products - News & Promotion - Job Vacancy - Mobile Website - Google - SEO Results

NEWPAGES

  • BR 15519
  • VN 6058
  • US 4743
  • IN 3101
  • AR 2243
  • CN 1996
  • BD 1581
  • ID 1522
People Online
Seni Jaya Logo
Brochure
Download
Our PackageContact Us