| input | ||
| type of the power supply network | 1-phase AC | |
| supply voltage at AC | Automatic range selection | |
| supply voltage | 120 V/230 V | |
| input voltage 1 at AC | 85 ... 132 V | |
| input voltage 2 at AC | 170 ... 264 V | |
| wide range input | No | |
| overvoltage overload capability | 2.3 × Vin rated, 1.3 ms | |
| buffering time for rated value of the output current in the event of power failure minimum | 20 ms | |
| operating condition of the mains buffering | at Vin = 93/187 V | |
| line frequency | 50/60 Hz | |
| line frequency | 47 ... 63 Hz | |
| input current | ||
| ● at rated input voltage 120 V | 2.3 A | |
| ● at rated input voltage 230 V | 1.2 A | |
| current limitation of inrush current at 25 °C maximum | 20 A | |
| duration of inrush current limiting at 25 °C | ||
| ● maximum | 3 ms | |
| I2t value maximum | 1.2 A²·s | |
| fuse protection type | T 3,15 A/250 V (not accessible) | |
| fuse protection type in the feeder | Recommended miniature circuit breaker: from 6 A characteristic C | |
| output | ||
| voltage curve at output | Controlled, isolated DC voltage | |
| output voltage at DC rated value | 24 V | |
| output voltage | ||
| ● at output 1 at DC rated value | 24 V | |
| output voltage adjustable | No; - | |
| relative overall tolerance of the voltage | 3 % | |
| relative control precision of the output voltage | ||
| ● on slow fluctuation of input voltage | 0.1 % | |
| ● on slow fluctuation of ohm loading | 0.5 % | |
| residual ripple | ||
| ● maximum | 50 mV | |
| ● typical | 10 mV | |
| voltage peak | ||
| ● maximum | 150 mV | |
| ● typical | 20 mV | |
| display version for normal operation | Green LED for 24 V OK | |
| behavior of the output voltage when switching on | No overshoot of Vout (soft start) | |
| response delay maximum | 2 s | |
| voltage increase time of the output voltage | ||
| ● typical | 10 ms | |
| output current | ||
| ● rated value | 5 A | |
| ● rated range | 0 ... 5 A | |
| supplied active power typical | 120 W | |
| short-term overload current | ||
| ● on short-circuiting during the start-up typical | 20 A | |
| ● at short-circuit during operation typical | 20 A | |
| duration of overloading capability for excess current | ||
| ● on short-circuiting during the start-up | 100 ms | |
| ● at short-circuit during operation | 100 ms | |
| bridging of equipment | Yes | |
| efficiency | ||
| efficiency in percent | 87 % | |
| power loss [W] | ||
| ● at rated output voltage for rated value of the output current typical | 18 W | |
| closed-loop control | ||
| relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical | 0.1 % | |
| relative control precision of the output voltage load step of resistive load 50/100/50 % typical | 1 % | |
| setting time | ||
| ● load step 50 to 100% typical | 0.3 ms | |
| ● load step 100 to 50% typical | 0.3 ms | |
| protection and monitoring | ||
| design of the overvoltage protection | Additional control loop, shutdown at < 28.8 V, automatic restart | |
| property of the output short-circuit proof | Yes | |
| design of short-circuit protection | Electronic shutdown, automatic restart | |
| response value current limitation | 5.5 ... 6.5 A | |
| enduring short circuit current RMS value | ||
| ● maximum | 7 A | |
| safety | ||
| galvanic isolation between input and output | Yes | |
| galvanic isolation | Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178 | |
| operating resource protection class | Class I | |
| leakage current | ||
| ● maximum | 3.5 mA | |
| ● typical | 0.5 mA | |
| protection class IP | IP20 | |
| EMC | ||
| standard | ||
| ● for emitted interference | EN 55022 Class B | |
| ● for mains harmonics limitation | EN 61000-3-2 | |
| ● for interference immunity | EN 61000-6-2 | |
| standards, specifications, approvals | ||
| certificate of suitability | ||
| ● CE marking | Yes | |
| ● UL approval | Yes; cULus-Listed (UL 508, CSA C22.2 No. 142), File E143289 | |
| ● UKCA marking | Yes | |
| ● EAC approval | Yes | |
| ● NEC Class 2 | No | |
| type of certification | ||
| ● BIS | Yes; R-41183539 | |
| ● CB-certificate | Yes | |
| MTBF at 40 °C | 2 480 589 h | |
| standards, specifications, approvals hazardous environments | ||
| certificate of suitability | ||
| ● IECEx | Yes; IECEx Ex nA nC IIC T3 Gc | |
| ● ATEX | Yes; ATEX (EX) II 3G Ex nA nC IIC T3 Gc | |
| ● ULhazloc approval | Yes | |
| ● UKEX | Yes | |
| ● CCC for hazardous zone according to GB standard | Yes | |
| ● FM registration | Yes; Class I, Div. 2, Group ABCD, T4 | |
| standards, specifications, approvals marine classification | ||
| shipbuilding approval | Yes | |
| Marine classification association | ||
| ● American Bureau of Shipping Europe Ltd. (ABS) | No | |
| ● French marine classification society (BV) | No | |
| ● Det Norske Veritas (DNV) | Yes | |
| ● Lloyds Register of Shipping (LRS) | Yes | |
| standards, specifications, approvals Environmental Product Declaration | ||
| Environmental Product Declaration | Yes | |
| global warming potential [CO2 eq] | ||
| ● total | 504.2 kg | |
| ● during manufacturing | 11.3 kg | |
| ● during operation | 492.3 kg | |
| ● after end of life | 0.41 kg | |
| ambient conditions | ||
| ambient temperature | ||
| ● during operation | 0 ... 60 °C; with natural convection | |
| ● during transport | -40 ... +85 °C | |
| ● during storage | -40 ... +85 °C | |
| environmental category according to IEC 60721 | Climate class 3K3, 5 ... 95% no condensation | |
| connection method | ||
| type of electrical connection | screw terminal | |
| ● at input | L, N, PE: 1 screw terminal each for 0.5 ... 2.5 mm² single-core/finely stranded | |
| ● at output | L+, M: 3 screw terminals each for 0.5 ... 2.5 mm² | |
| ● for auxiliary contacts | - | |
| mechanical data | ||
| width × height × depth of the enclosure | 60 × 125 × 120 mm | |
| installation width × mounting height | 60 mm × 205 mm | |
| required spacing | ||
| ● top | 40 mm | |
| ● bottom | 40 mm | |
| ● left | 0 mm | |
| ● right | 0 mm | |
| fastening method | Can be mounted onto S7 rail | |
| ● DIN-rail mounting | No | |
| ● S7 rail mounting | Yes | |
| ● wall mounting | No | |
| housing can be lined up | Yes | |
| net weight | 0.6 kg | |
| accessories | ||
| mechanical accessories | Mounting adapter for standard mounting rail (6EP1971-1BA00) | |