| General technical data | |||
| product brand name | SIRIUS | ||
| product designation | Soft starter | ||
| product feature | |||
| ● integrated bypass contact system | Yes | ||
| ● thyristors | Yes | ||
| product function | |||
| ● intrinsic device protection | Yes | ||
| ● motor overload protection | Yes | ||
| ● evaluation of thermistor motor protection | No | ||
| ● external reset | Yes | ||
| ● adjustable current limitation | Yes | ||
| ● inside-delta circuit | No | ||
| product component motor brake output | No | ||
| insulation voltage rated value | V | 600 | |
| degree of pollution | 3, acc. to IEC 60947-4-2 | ||
| blocking voltage of the thyristor maximum | V | 1 600 | |
| reference code according to EN 61346-2 | Q | ||
| reference code according to DIN 40719 extended according to IEC 204-2 according to IEC 750 | G | ||
| Power Electronics | |||
| operational current | |||
| ● at 40 °C rated value | A | 32 | |
| ● at 50 °C rated value | A | 29 | |
| ● at 60 °C rated value | A | 26 | |
| yielded mechanical performance for 3-phase motors | |||
| ● at 230 V | |||
| — at standard circuit at 40 °C rated value | kW | 7.5 | |
| ● at 400 V | |||
| — at standard circuit at 40 °C rated value | kW | 15 | |
| yielded mechanical performance [hp] for 3-phase AC motor at 200/208 V at standard circuit at 50 °C rated value | hp | 7.5 | |
| operating frequency rated value | Hz | 50 ... 60 | |
| relative negative tolerance of the operating frequency | % | -10 | |
| relative positive tolerance of the operating frequency | % | 10 | |
| operating voltage at standard circuit rated value | V | 200 ... 480 | |
| relative negative tolerance of the operating voltage at standard circuit | % | -15 | |
| relative positive tolerance of the operating voltage at standard circuit | % | 10 | |
| minimum load [%] | % | 20 | |
| adjustable motor current for motor overload protection minimum rated value | A | 17 | |
| continuous operating current [% of Ie] at 40 °C | % | 115 | |
| power loss [W] at operational current at 40 °C during operation typical | W | 13 | |
| Control circuit/ Control | |||
| type of voltage of the control supply voltage | AC/DC | ||
| control supply voltage frequency 1 rated value | Hz | 50 | |
| control supply voltage frequency 2 rated value | Hz | 60 | |
| relative negative tolerance of the control supply voltage frequency | % | -10 | |
| relative positive tolerance of the control supply voltage frequency | % | 10 | |
| control supply voltage 1 at AC at 50 Hz | V | 110 ... 230 | |
| control supply voltage 1 at AC at 60 Hz | V | 110 ... 230 | |
| relative negative tolerance of the control supply voltage at AC at 50 Hz | % | -15 | |
| relative positive tolerance of the control supply voltage at AC at 50 Hz | % | 10 | |
| relative negative tolerance of the control supply voltage at AC at 60 Hz | % | -15 | |
| relative positive tolerance of the control supply voltage at AC at 60 Hz | % | 10 | |
| control supply voltage 1 at DC | V | 110 ... 230 | |
| relative negative tolerance of the control supply voltage at DC | % | -15 | |
| relative positive tolerance of the control supply voltage at DC | % | 10 | |
| display version for fault signal | red | ||
| Mechanical data | |||
| size of engine control device | S0 | ||
| width | mm | 45 | |
| height | mm | 125 | |
| depth | mm | 155 | |
| fastening method | screw and snap-on mounting | ||
| mounting position | With additional fan: With vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back Without additional fan: With vertical mounting surface +/-10° rotatable, with vertical mounting surface +/- 10° t | ||
| required spacing with side-by-side mounting | |||
| ● upwards | mm | 60 | |
| ● at the side | mm | 15 | |
| ● downwards | mm | 40 | |
| wire length maximum | m | 300 | |
| number of poles for main current circuit | 3 | ||
| Connections/ Terminals | |||
| type of electrical connection | |||
| ● for main current circuit | screw-type terminals | ||
| ● for auxiliary and control circuit | screw-type terminals | ||
| number of NC contacts for auxiliary contacts | 0 | ||
| number of NO contacts for auxiliary contacts | 2 | ||
| number of CO contacts for auxiliary contacts | 1 | ||
| type of connectable conductor cross-sections for main contacts for box terminal using the front clamping point | |||
| ● solid | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), max. 1x 10 mm² | ||
| ● finely stranded with core end processing | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²) | ||
| type of connectable conductor cross-sections for AWG cables for main contacts for box terminal | |||
| ● using the front clamping point | 1x 8, 2x (16 ... 10) | ||
| type of connectable conductor cross-sections for auxiliary contacts | |||
| ● solid | 2x (0.5 ... 2.5 mm²) | ||
| ● finely stranded with core end processing | 2x (0.5 ... 1.5 mm²) | ||
| type of connectable conductor cross-sections for AWG cables | |||
| ● for auxiliary contacts | 2x (20 ... 14) | ||
| ● for auxiliary contacts finely stranded with core end processing | 2x (20 ... 16) | ||
| Ambient conditions | |||
| installation altitude at height above sea level | m | 5 000 | |
| environmental category | |||
| ● during transport according to IEC 60721 | 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) | ||
| ● during storage according to IEC 60721 | 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 | ||
| ● during operation according to IEC 60721 | 3K6 (no formation of ice, no condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 | ||
| ambient temperature | |||
| ● during operation | °C | -25 ... +60 | |
| ● during storage | °C | -40 ... +80 | |
| derating temperature | °C | 40 | |
| protection class IP on the front according to IEC 60529 | IP20 | ||
| touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front | ||
| Environmental footprint | |||
| Environmental Product Declaration(EPD) | Yes | ||
| global warming potential [CO2 eq] total | kg | 121 | |
| global warming potential [CO2 eq] during manufacturing | kg | 4.24 | |
| global warming potential [CO2 eq] during sales | kg | 0.207 | |
| global warming potential [CO2 eq] during operation | kg | 117 | |
| global warming potential [CO2 eq] after end of life | kg | -0.229 | |
| UL/CSA ratings | |||
| yielded mechanical performance [hp] for 3-phase AC motor | |||
| ● at 220/230 V | |||
| — at standard circuit at 50 °C rated value | hp | 7.5 | |
| ● at 460/480 V | |||
| — at standard circuit at 50 °C rated value | hp | 20 | |
| contact rating of auxiliary contacts according to UL | B300 / R300 | ||