🔧 How Do I Qualify a Welding Procedure? (WPS Process Step by Step)
As a mechanical engineer working in pipe manufacturing, qualifying a welding procedure is not just a technical task — it’s a guarantee of quality and safety.
Here’s how to from a concept to a qualified WPS 👇
.;
1. Start with a pWPS (Preliminary Welding Procedure Specification):
I prepare a draft based on project specs and the applicable standard (e.g., API 5L or ASME IX).
It includes:
" Welding process: SAW / GMAW / SMAW
" Joint type & groove design
" Base metal grade
" Filler wire & flux
" Preheat & interpass temperatures
" Welding positions and passes
" Voltage, amperage, travel speed
.;
2. Perform the Welding Trial:
Using the pWPS, we weld a test coupon under controlled conditions.
All parameters are monitored and recorded carefully.
.;
3. Non-Destructive Testing (NDT):
Before we cut the coupon, we apply:
" Visual Inspection (VT)
" Ultrasonic Testing (UT) or Radiography (RT)
This ensures surface and internal weld soundness.
.;
4. Destructive Testing (DT):
We cut and test the coupon to verify:
" Tensile strength
" Bend test
" Impact test (for PSL 2 or low-temperature service)
" Macro/micro examination
" Hardness test (if required)
.;
5. Issue PQR (Procedure Qualification Record):
If all results meet the code and project requirements, we record them in the PQR, which validates the process.
.;
6. Final WPS Approval:
Based on the PQR, the Welding Procedure Specification (WPS) is issued and approved for production use.
.;
This cycle ensures that every weld meets performance expectations before it even reaches the field.









 
            
             
             
		

 
                 
 BR                                19310
BR                                19310                             VN                                9562
VN                                9562                             US                                3284
US                                3284                             CN                                1770
CN                                1770                             AR                                1752
AR                                1752                             MY                                1024
MY                                1024                             SG                                934
SG                                934                             EC                                837
EC                                837                             
         
        
 
        