请登录后使用此功能。 您可以使用此功能将商品添加到您的收藏列表。
关闭
您已经添加该商品到您的收藏列表。 查看我的收藏
关闭
从您收藏列表中删除此商品。
关闭
请登录后使用此功能。 您可以使用此功能将公司添加到您的收藏夹列表。
关闭
这家公司已成功添加。 查看我的收藏
关闭
这家公司已从你的收藏夹列表中删除。
关闭
请登录后使用此功能。 您可以使用此功能将公司添加到您的询问车。
关闭
这家公司已被添加到您的询问车。
关闭
这家公司已从询价车中删除。
关闭
该商品已被添加到您的询问车。
关闭
该商品已经从您的询价车中删除。
关闭
商品/公司已达到添加至询价车的数量。
关闭
ZABSI Industrial Ventilation Sdn. Bhd.
ZABSI Industrial Ventilation Sdn. Bhd. 201501037613 (1162934-H)
营业
时间
星期一 - 星期四 8:30 AM - 5:30 PM
星期五 - 星期六 休息
星期日 8:30 AM - 5:30 PM
我们在 公共假期休息
营业 休息
Onesync Platinum

Top 5 Mistakes Factories Make in LEV System Design (and How to Avoid Them)

22-Jul-2025

Avoid costly errors in your LEV system design. Discover the top 5 mistakes Malaysian factories make and learn how ZABSI ensures compliance, performance, and safety.

Introduction

When it comes to protecting workers from airborne contaminants, a properly designed Local Exhaust Ventilation (LEV) system is critical. Yet, many factories across Malaysia unknowingly operate with poorly designed systems that fail to meet DOSH and USECHH 2000 requirements.

In this article, we reveal the 5 most common LEV design mistakes seen in Malaysian factories and offer expert advice from ZABSI Industrial Ventilation Sdn Bhd on how to avoid them — saving you from future non-compliance issues, shutdowns, or worker health risks.


1. Using Undersized Fans

Many systems are installed with fans that lack the required airflow (CFM) or static pressure to capture hazardous fumes at the source. This results in poor contaminant capture and system inefficiency.

Solution:
Always size the fan based on calculated capture velocity, duct friction loss, hood design, and application type. At ZABSI, we use precise engineering calculations and CFD modeling when needed.


2. Poor Hood Design or Placement

Improperly placed or designed hoods reduce the system’s ability to capture contaminants. This is especially common in welding, chemical mixing, or blasting processes.

Solution:
Ensure the hood is correctly shaped and positioned near the emission source. ZABSI provides custom hood designs based on actual process layout and worker movement.


3. Incorrect Duct Sizing and Layout

Using ducts that are too small, too long, or have sharp bends increases pressure drop and reduces airflow. Inconsistent duct diameters across a system can also cause performance issues.

Solution:
Design ducting with consistent diameters, minimal bends, and smooth transitions. Our team uses duct design software to simulate airflow before fabrication.


4. Neglecting Filter Selection and Maintenance

Many systems fail due to cheap filters, wrong filter types, or poor access for maintenance. This affects both performance and safety, especially when handling corrosive or oily fumes.

Solution:
Select filters based on the contaminant (e.g. HEPA for particulates, activated carbon for vapors). ZABSI offers filtration units with easy-access maintenance doors and proper sealing.


5. No Provision for Monitoring or Testing

Factory owners often neglect to install test points, velocity indicators, or pressure gauges, making it hard to monitor performance or conduct LEV inspections later.

Solution:
Design with performance monitoring in mind. ZABSI installs velocity test ports, pressure gauges, and even smoke test view panels to facilitate inspection and maintenance.


Bonus: Regulatory Oversight

Under USECHH 2000, an improperly designed LEV system is a compliance risk. It must undergo annual LEV inspections and be documented by a competent person. A flawed design makes it nearly impossible to pass.


Why Work with ZABSI?

10+ years of LEV design experience
In-house engineering team with DOSH knowledge
Tailored solutions for each process 
End-to-end service: site visit → design → purchasing → installation → inspection

We’ve supported factories in the oil & gas, chemical, palm oil, and automotive sectors to design LEV systems that perform and comply.


Ready to Upgrade or Redesign Your LEV System?

Whether you’re building a new factory or fixing an existing issue — we’re here to help.

Get a FREE Design Consultation
 


ZABSI Industrial Ventilation – LEV Done Right.

Serving Terengganu, Pahang, Johor, Selangor, and more.

总办事处

ZABSI Industrial Ventilation Sdn. Bhd. 201501037613 (1162934-H)
PT 15975 & PT 15976, Tingkat Atas, Jalan Air Putih, 24000 Kemaman, Terengganu, Malaysia.

电话:

邮件:
网址: https://www.zabsi.com
网址: https://zabsi.newpages.com.my/
网址: https://zabsi.onesync.my/

游览 : 首页 - 分类 - 公司 - 地区 - 标签 - 商品 - 消息与促销 - 工作征聘 - 手机版 - 谷歌 - 搜索引擎优化结果

NEWPAGES

  • US 12051
  • GB 9292
  • CA 8591
  • AU 8147
  • IE 6255
  • BR 2435
  • NZ 1885
  • SG 621
人 在线
Seni Jaya Logo
Brochure
Download
Our PackageContact Us