Description
The PEL106 is a DC, single-phase, two-phase, and three-phase (wye and D) power and energy logger in a rugged sealed housing.
The PEL has all power/energy recording functions needed for most of the world's 50Hz, 60Hz, 400Hz, and DC distribution networks, with many connection possibilities to suit different installations. It is designed to operate in 1,000V CAT IV environments, both indoors and out.
The PEL has a battery with which to continue to operate if there is a power outage. The battery is recharged during the measurements.
The instrument has the following functions:
Discontinued
Description
The PEL106 is a DC, single-phase, two-phase, and three-phase (wye and D) power and energy logger in a rugged sealed housing.
The PEL has all power/energy recording functions needed for most of the world's 50Hz, 60Hz, 400Hz, and DC distribution networks, with many connection possibilities to suit different installations. It is designed to operate in 1,000V CAT IV environments, both indoors and out.
The PEL has a battery with which to continue to operate if there is a power outage. The battery is recharged during the measurements.
The instrument has the following functions:
- Direct measurements of voltages up to 1,000V CAT IV.
- Direct measurements of currents from 5mA to 10,000A depending on the current sensors.
- Measurements of the neutral current on the 4th current terminal.
- Measurements of the voltage between earth and neutral on the 5th voltage terminal.
- Measurements of active power (W), reactive power (var), and apparent power (VA).
- Measurements of the fundamental, unbalance, and harmonic active powers.
- Measurement of current and voltage unbalances by the IEEE 1459 method.
- Measurements of active energy at source and load (Wh), 4-quadrant reactive energy (varh), and apparent energy (VAh).
- Power factor (PF), cos and tan Φ.
- Crest factor.
- Total harmonic distortion (THD) of voltages and currents.
- Voltage and current harmonics up to the 50th at 50/60Hz.
- Frequency measurements.
- Simultaneous RMS and DC measurements on each phase.
- LCD display unit with blue backlighting (simultaneous display of 4 quantities).
- Storage of measured and calculated values on SD or SDHC card.
- Automatic recognition of the various types of current sensor.
- Configuration of the transformation ratios for the current and voltage inputs.
- Management of 17 types of connection or power distribution networks.
- Communication with up to four data loggers - L452 Data Loggers (optional), to record voltages, currents, and events).
- 32 programmable alarms on the measurements or on the analog inputs with the L452 Data Logger (optional), which communicates via Bluetooth.
- USB, LAN (Ethernet), Bluetooth, Wi-Fi and 3G-UMTS/GPRS communication.
- PEL Transfer software for data recovery, configuration, and real-time communication with a PC.
- Android application to communicate in real time and configure the PEL from a smartphone or a tablet.
- IRD server to communicate using private IP addresses.
- Sending of periodic reports by email.
PEL Transfer Software
The PEL Transfer software can also provide a breakdown of the types of energy and their losses. Users have access to all the
elements needed to establish the priority of their operations.
- Useful energy
- Active unbalance energy
- Active harmonic energy
- Non-active energy
- Reactive energy
- Distorting energy
- Apparent energy
Analogue measurements
The PEL106 can be used to identify each of the dysfunctions by recording external parameters such as the pressure, temperature,
torque, etc.
Via its Bluetooth wireless link, it communicates with remote L452 dataloggers. The PEL106’s recording function can integrate up to 2 x 8 analogue channels. The analogue channels complement the voltage, current and power measurements.
Energy consumption of a motor, transformer station, etc.
When used with remote L452 loggers, the PEL106 records analogue measurements (external parameters, up to 2x8 channels) such as the temperature, pressure, motor torque, etc. It can also be used to analyse a temperature-affected motor, for example, or electrical transformer station.
Renewable energy
The PEL106’s analogue measurement function offers the possibility of linking electricity generation to a wind speed or a hydro-electric current to a flow-rate.
It meets the requirements of the applications in the renewable energies sector, such as metering the energy linked to the strength of the wind, for example.
The PEL106 accurately measures the energy efficiency of wind turbines, which depend on the wind speed, or hydro-electric dams,
which depend on the water flow-rate, etc.
State At Delivery:
PEL106 with:
1 bag for the accessories, 5 x IP67 voltage cables, 5 lockable crocodile clips, 1 set of rings/inserts, PC software (PEL Transfer), 1 SD card, 1 SD -USB adapter, 1 USB cable, 1 user’s manual in multiple languages, 1 quick start guide.
References To Order: