请登录后使用此功能。 您可以使用此功能将商品添加到您的收藏列表。
关闭
您已经添加该商品到您的收藏列表。 查看我的收藏
关闭
从您收藏列表中删除此商品。
关闭
请登录后使用此功能。 您可以使用此功能将公司添加到您的收藏夹列表。
关闭
这家公司已成功添加。 查看我的收藏
关闭
这家公司已从你的收藏夹列表中删除。
关闭
请登录后使用此功能。 您可以使用此功能将公司添加到您的询问车。
关闭
这家公司已被添加到您的询问车。
关闭
这家公司已从询价车中删除。
关闭
该商品已被添加到您的询问车。
关闭
该商品已经从您的询价车中删除。
关闭
商品/公司已达到添加至询价车的数量。
关闭
Sunmoon Aircond & Electrical Sdn Bhd
Sunmoon Aircond & Electrical Sdn Bhd 201501025580 (1150903-W)
营业
时间
星期一 - 星期五 8:30 AM - 5:30 PM
星期六 8:30 AM - 1:00 PM
星期日 休息
我们在 公共假期休息
营业 休息
SSM
访客

雪兰莪,吉隆玻,万饶 - 供应商 Panasonic VRF-FSV- space saving high efficiency combinaation model

25-Aug-2025

Panasonic VRF-FSV- space saving high efficiency combinaation model

标签:
-
产品已浏览 24

FSV-EX
The most efficient, powerful and quiet system in Panasonic's history. There has never been a VRF system like it. It’s the story of a true game changer.

PRODUCT FEATURES:

Extraordinary energy-saving performance

The FSV-EX marks a revolutionary step forward in VRF efficiency. A look at the incredible EER value clearly indicates that. What's more, this high EER value is achieved even during part load operation. This shows the extraordinary energy-saving performance the FSV-EX is capable of providing.



Extended operation range up to 52°C
The FSV-EX can provide cooling even when the outside temperature reaches a maximum of about 52°C. And amazingly, it can still operate at 100% capacity when the outside temperature is as high as 43°C. This high power capability enables reliable operation even under extremely high temperature conditions.







Low-noise operation
Numerous technological innovations, including an improved compressor and a newly designed bell mouth and larger fan, have dramatically reduced the outdoor noise level. The result is an even more comfortable building environment.



Multiple large-capacity all inverter twin rotary compressor (more than 14HP)
Two independently controlled inverter compressors achieve high efficiency. Redesigned components in the body provide performance improvement especially in the rated cooling condition and EER performance.



Enlarged heat exchanger surface area with triple surface*
The new heat exchanger features a triple-surface construction. Compared to the divided dual-surface construction in current models, there is no division of space and the area for heat exchange is larger. Also, highly efficient piping pattern increases heat exchange performance by 5%.

* For 8,10,12HP unit, the heat exchanger is 2 row design.



ADVANTAGES:
Increased piping length for greater design flexibility
*1: 40 m if the outdoor unit is below the indoor unit. Elevation difference of Max. 90m in case of ODU is higher than IDU may be allowed following certain conditions.
*1, *2: Please consult with Panasonic sales engineers about the certain conditions in case of piping elevation of over 50m or level difference between indoor units over 15m is required.

Adaptable to various building types and sizes
Actual piping length : 200m
(equivalent piping length : 210m)





Connectable indoor/outdoor unit capacity ratio up to 130%*1
FSV systems attain maximum indoor unit connection capacity of up to 130 %*1 of the unit’s connection range, depending on the outdoor and indoor models selected. So for a reasonable investment, FSV systems provide an ideal air conditioning solution for locations where full cooling/heating are not always required.

*82HP and above is equivalent to 80HP.










Wide operating range
• Cooling operation is possible when outdoor temperature as low as 10°C DB
• Cooling operation is possible when outdoor temperature as high as 52°C DB
- The remote controller temperature can be set from 18°C up to 30°C (Cooling)
* Depending on the type of remote controller.

              
High external static pressure on condensers
With a newly designed fan, fan guard, motor, and casing, new models can be custom-installed on-site to provide up to 80 Pa of external static pressure. An air discharge duct prevents shortages of air circulation, allowing outdoor units to be installed on every floor of a building.



Prevents unit stoppages due to short circuits caused by geckos
One of the common causes of failures of the outdoor unit is electrical short circuits caused by geckos, small animals such as rats and insects entering the unit. The unit eliminates gaps that prevent geckos from entering the internal PCB and thus prevent operation stoppages.







Excellent energy savings
The operation efficiency has been improved using highly efficient R410A refrigerant, new DC inverter
compressor, and new heat exchanger design.

































 

发信息至 Sunmoon Aircond & Electrical Sdn Bhd
谢谢您的询问!
我们的客服会尽快联络您。
您的名字 *
您的公司名字
您的邮件 *
您的联络号码 *
标题 *
信息 *
验证码 *
总办事处

Sunmoon Aircond & Electrical Sdn Bhd 201501025580 (1150903-W)
13, Jalan MR 1/4, M Avenue Off M Residence, 48020 Rawang, Selangor, Malaysia.

电话:

邮件:
网址: https://www.sunmoonhvac.com
网址: https://sunmoon.newpages.com.my/
网址: https://sunmoon.onesync.my/

游览 : 首页 - 分类 - 公司 - 地区 - 标签 - 商品 - 消息与促销 - 工作征聘 - 手机版 - 谷歌 - 搜索引擎优化结果

NEWPAGES

  • BR 24697
  • VN 11347
  • US 10681
  • TR 2188
  • AR 1902
  • CN 1845
  • AU 1696
  • CA 1646
人 在线
Seni Jaya Logo
Brochure
Download
Our PackageContact Us