请登录后使用此功能。 您可以使用此功能将商品添加到您的收藏列表。
关闭
您已经添加该商品到您的收藏列表。 查看我的收藏
关闭
从您收藏列表中删除此商品。
关闭
请登录后使用此功能。 您可以使用此功能将公司添加到您的收藏夹列表。
关闭
这家公司已成功添加。 查看我的收藏
关闭
这家公司已从你的收藏夹列表中删除。
关闭
请登录后使用此功能。 您可以使用此功能将公司添加到您的询问车。
关闭
这家公司已被添加到您的询问车。
关闭
这家公司已从询价车中删除。
关闭
该商品已被添加到您的询问车。
关闭
该商品已经从您的询价车中删除。
关闭
商品/公司已达到添加至询价车的数量。
关闭
EKG M & E SDN BHD
EKG M & E SDN BHD 201201033712 (1018200-D)
营业
时间
星期一 - 星期五 9:00 AM - 5:30 PM
星期六 9:00 AM - 1:00 PM
星期日 休息
我们在 公共假期休息
营业 休息
Onesync AI SSM
访客

30-Mar-2026

Ductwork Tightness Test | Precision Airflow Delivery by EKG

In the high-performance building landscape of 2026 Kuala Lumpur, a Ductwork Tightness Test—commonly referred to as a Duct Air Leakage Test (DALT)—is the only definitive way to verify that your cooling energy is reaching its intended destination. Even the most efficient VSD-driven AHU is undermined if 15% to 30% of the treated air escapes into ceiling voids. Under the Energy Efficiency & Conservation Act (EECA) 2024, these "invisible losses" are now a primary target for mandatory operational cost reduction.

As part of our specialized Duct Leakage Testing suite, EKG M&E provides the certified pressure testing required to ensure your ventilation system is "Airtight and Energy-Right."


1. The Physics of "System Tightness"

Duct leakage follows the laws of fluid dynamics, where small gaps lead to massive system inefficiencies:

  • The Square Law of Pressure: Leakage increases exponentially with duct static pressure ($Pa$). If your VSD is pushing higher pressure to reach a "Hot Zone" in your office, your leakage rate through existing gaps doubles.

  • The Cube Law Multiplier: Because of the Fan Affinity Laws, if leaks force your fan to run at 10% higher speed to maintain airflow at the diffusers, your energy consumption jumps by 33%.

  • Latent Heat Infiltration: In KL’s 90% humidity, a pressure drop at a leak point can suck warm, moist "Plenum Air" into the supply stream, leading to Ceiling Sweating and mold growth.


2. The EKG "Tightness-Verify" Protocol

We perform testing according to SMACNA or BESA DW/143 standards used in Tier-1 KL commercial projects:

  • Sectional Pressurization: We isolate a specific run of ductwork using inflatable "Duct Plugs." We then connect a calibrated Duct Leakage Tester (a high-pressure fan with an integrated flow orifice).

  • Leakage Class Verification: We pressurize the duct to its "Design Operating Pressure" (e.g., 250 Pa, 500 Pa, or 1000 Pa). We measure the exact amount of air ($L/s$) required to maintain that pressure to determine if your system meets Class A, B, or C leakage standards.

  • Ultrasonic Leak Pinpointing: For inaccessible risers, we use Ultrasonic Transmitters. We place a "Pinger" inside the duct and use a handheld receiver outside to hear high-frequency "leakage noise" through the insulation.

  • Visual Confirmation (Smoke/Thermal): We use Non-Toxic Artificial Smoke or FLIR Thermal Cameras to visually confirm exactly where the seal has failed, allowing for surgical repairs without tearing down the entire ceiling.


3. The Energy & Regulatory ROI (EECA 2024)

A certified Tightness Test provides the data needed for a high-ROI remediation plan:

  • VSD Frequency Optimization: Once the leaks are sealed, we re-calibrate your VSD. By dropping the fan speed to match the now-efficient system, we capture Cube Law energy savings immediately.

  • EECA Compliance Reporting: We provide the "Certified Leakage Report" required for your building's 2026 Energy Intensity Label audit.

  • IAQ & Pressure Balancing: A tight system ensures that the design Outdoor Air (OA) requirements reach every room, maintaining compliance with the 2026 DOSH ICOP IAQ standards.


4. Duct Tightness Performance Matrix

Leakage Class Standard Limit (L/s⋅m2) Typical Application (2026 KL)
Class A 0.027 \times P^0.65 Low-Pressure Supply / Return
Class B 0.009 \times P^0.65 Medium-Pressure AHU Risers
Class C 0.003 \times P^0.65 High-Pressure VAV Main Headers
Class D 0.001 \times P^0.65 Cleanrooms / Hospital Isolation

5. Why Trust EKG for Tightness Testing?

  • Mechanical Restoration Path: We are experts in Mechanical Fan Overhauls. We ensure your AHU is physically capable of the pressure required for a valid test.

  • VFD-Energy ROI Projection: We provide a report showing exactly how many Ringgit per Month are being lost through the measured leakage.

  • 2026 Technical Standards: Every test includes a Certified Leakage Report compliant with SMACNA or DW/143 standards.

  • KL/Selangor Expertise: We specialize in "After-Hours" testing for occupied office towers (KLCC, TRX) to ensure zero noise disruption for your tenants.

发信息至 EKG M & E SDN BHD
谢谢您的询问!
我们的客服会尽快联络您。
您的名字 *
您的公司名字
您的邮件 *
您的联络号码 *
标题 *
信息 *
验证码 *
总办事处

EKG M & E SDN BHD 201201033712 (1018200-D)
27-2 & 27-3, Jalan Kuchai Maju, Kuchai Entrepreneur’s Park, Off Jalan Kuchai Lama, 58200 Kuala Lumpur, Malaysia.

电话:

邮件:
网址: https://www.eakon.com.my
网址: https://eakon.newpages.com.my/
网址: https://eakon.onesync.my/

游览 : 首页 - 分类 - 公司 - 地区 - 标签 - 商品 - 消息与促销 - 工作征聘 - 手机版 - 谷歌 - 搜索引擎优化结果

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us