请登录后使用此功能。 您可以使用此功能将商品添加到您的收藏列表。
关闭
您已经添加该商品到您的收藏列表。 查看我的收藏
关闭
从您收藏列表中删除此商品。
关闭
请登录后使用此功能。 您可以使用此功能将公司添加到您的收藏夹列表。
关闭
这家公司已成功添加。 查看我的收藏
关闭
这家公司已从你的收藏夹列表中删除。
关闭
请登录后使用此功能。 您可以使用此功能将公司添加到您的询问车。
关闭
这家公司已被添加到您的询问车。
关闭
这家公司已从询价车中删除。
关闭
该商品已被添加到您的询问车。
关闭
该商品已经从您的询价车中删除。
关闭
商品/公司已达到添加至询价车的数量。
关闭
ALTAAS Topologies Sdn Bhd
ALTAAS Topologies Sdn Bhd 1257064-U
营业
时间
星期一 - 星期六 9:30 AM - 6:30 PM
星期日 休息
我们在 公共假期休息
营业 休息
SSM
商业性质:

提供者

雪兰莪,吉隆玻,八打灵再也 - THOR Lightning Strike Counter (TRSC)

11-Apr-2023

THOR Lightning Strike Counter (TRSC) Production  introduction:

 
System failures happen. Replacing equipment is expensive. Often the cause of problems stays undetermined. Lightning damage is often subtle and the underlying cause of undocumented failure. The Lightning Strike Counter keeps track of the number of times that a facility or equipment has suffered a direct strike and can assist in determining the need for additional means of security such as grounding, surge suppression, and lightning protection.
 
The lightning counter is suitable for counting the number of lightning discharge currents of various lightning protection devices. The counting times are two digits, which expands the function that only counted in units in the past, up to 99 times. The lightning counter is installed on the lightning protection module that needs to discharge lightning current, such as the ground wire of the lightning protection device. The initial counting current is 1 Ka, and the maximum counting current is 150 kA. Power failure in the lightning counter can protect data for up to 1 month. The lightning counter is equipped with a current transformer.
 
When installing and using, put the core of the current transformer into the PE wire of the surge protector, and lead the two very wires of the times coil of the transformer into the terminals 5 and 6 of the lightning counter and connect them firmly. When a surge occurs, the surge protector discharges the lightning current into the ground, and the transformer induces the lightning current. After sampling, it is coupled to the counter. After the counter processes the lightning signal through the internal integrated circuit, it is displayed on the LED digital tube. Switch to display the number of lightning discharge currents.
 
The lightning current counter has six binding posts. The two binding posts 1, 2 are connected to the N and L wires to provide charging power for the counter; the middle 3 and 4 two binding posts, short-circuit the counter to reset the counter; 5, 6 two Two terminals lead into the two wires of the current transformer coil.


 

THOR Lightning Strike Counter (TRSC) Dimension:



 

THOR Lightning Strike Counter (TRSC) Wiring Diagram




 
 
发信息至 ALTAAS Topologies Sdn Bhd
谢谢您的询问!
我们的客服会尽快联络您。
您的名字 *
您的公司名字
您的邮件 *
您的联络号码 *
标题 *
信息 *
验证码 *
总办事处

ALTAAS Topologies Sdn Bhd 1257064-U
Unit D-8-05, Oasis Square (Building Capital 4) No. 2, Jalan PJU1A/7A, Ara Damansara, 47301 Petaling Jaya, Selangor, Malaysia.

电话:

邮件:
网址: https://www.altaaslogies.com
网址: https://altaaslogies.newpages.com.my/
网址: https://altaaslogies.n.my/

游览 : 首页 - 分类 - 公司 - 地区 - 标签 - 商品 - 消息与促销 - 工作征聘 - 手机版 - 谷歌 - 搜索引擎优化结果

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us