TDR sensor for continuous level and interface measurement of liquids
For aggressive media or extremely high hygienic requirements
Application area
PFA coated or polished sensor. Even in applications with steam, buildup, foam or condensation, the sensor delivers precise and reliable readings.
The VEGAFLEX 83 level sensor measures maintenance-free agressive liquids or liquid media with highest hygienic requirements. Even in applications with vapour, buildup, foam generation and condensation, the sensor delivers precise and reliable measured values. The VEGAFLEX 83 is the economical and ideal solution for your application.
Your benefit
- The gap-free hygienic design ensures simple and reliable cleanability
- The maintenance-free operation increases the plant efficiency
- The guided adjustment enables a simple, time-saving and reliable setup
| Technical Specifications | |
| Measuring range - Distance | 32m |
| Process temperature | -40 ... 150 °C |
| Process pressure | -1 ... 16 bar |
| Accuracy | ± 2 mm |
| Version |
|
| Flange connection | ≥ DN25, ≥ 1'', hygenic fittings, clamp, slotted nut |
| Housing material |
|
| Protection rating |
|
| Output | Profibus PA, Foundation Fieldbus, 4 … 20 mA/HART - two-wire, Modbus, 4 … 20 mA/HART - four-wire |
| Approvals | ATEX, CSA, FM, EAC (GOST), IEC, NEPSI, UKR Sepro, INMETRO, CCOE, Explosion protection, EHEDG, FDA, Ship, Overfill protection, SIL2 |
Refer to the link for more details: https://www.vega.com/en/home_de/products/product-catalog/level/guided-wave-radar/vegaflex-83





BR 20939
VN 6861
MY 5189
US 2379
AR 1940
CN 1233
EC 864
MX 555