Ideal for Production Lines of Electronic Parts and Automated Testing
OVERVIEW




Hioki LCR Meters and Impedance Analyzers range from 1 mHz to 3 GHz devices to suit a wide range of applications in the testing of electronic components. The IM3523A is designed for basic measurement on production lines so that it can be offered at a low price point, and delivers improved measurement reliability thanks to its contact check function.
Key Features
- ±0.05% accuracy with wide measurement range (DC, 40Hz to 200kHz, 5mV to 5V, 10uA to 50mA)
- Rapid 2 msec test time
- Built-in comparator and BIN functions
- Non-stop testing over mixed measurement conditions such as C-D(120 Hz) and ESR(100 kHz) at 10 times the speed of previous models (compared with Model 3532-50)
IM3523A | LCR Meter |
This product is not supplied with measurement probes or test fixtures. Please select and purchase the measurement probe or test fixture options appropriate for your application separately. All probes are constructed with a 1.5D-2V coaxial cable.
FEATURES
Application information
Download the sample application and view the Communications Command User Manual.
Click here for the LCR application.
Accuracy calculation information
Calculate accuracy by simply entering a numerical value.
Click here to calculate accuracy.
SPECIFICATIONS
Basic specifications
Accuracy guaranteed: 1 year
Measurement modes | LCR (Measurement with single condition), Continuous testing (Continuous measurement under saved conditions) | |||||
---|---|---|---|---|---|---|
Measurement parameters | Z, Y, θ, X, G, B, Q, Rdc (DC resistance), Rs (ESR), Rp, Ls, Lp, Cs, Cp, D (tanδ) | |||||
Measurement range | 100 mΩ to 100 MΩ, 10 ranges (All parameters defined in terms of Z.) | |||||
Displayable range | Z, Y, Rs, Rp, Rdc, X, G, B, Ls, Lp, Cs, Cp : ± (0.00000 [unit] to 9.99999G [unit]) Real value display for Z and Y only θ: ± (0.000° to 180.000°), D: ± (0.00000 to 9.99999) Q: ± (0.00 to 99999.9), Δ%: ± (0.0000% to 999.999%) |
|||||
Basic accuracy | Z : ±0.05% rdg. θ: ±0.03° | |||||
Measurement frequency | 40 Hz to 200 kHz (5 digits setting resolution) | |||||
Measurement signal level | V mode, CV mode: 5 mV to 5 Vrms, 1 mVrms steps CC mode: 10 μA to 50 mArms, 10 μArms steps |
|||||
Output impedance | 100 Ω | |||||
Display | Monochrome LCD | |||||
Measurement time | 2 ms (1 kHz, FAST, representative value) | |||||
Functions | Comparator, BIN measurement (classify function), Panel loading/saving, Memory function | |||||
Interfaces | EXT I/O (handler), USB communication (full-speed), LAN | |||||
Power supply | 100 to 240 V AC, 50/60 Hz, 50 VA max | |||||
Dimensions and mass | 260 mm (10.24 in) W × 88 mm (3.46 in) H × 203 mm (7.99 in) D, 2.1 kg (84.7 oz) | |||||
Included accessories | Power cord × 1 , CD-R (Includes Instruction manual, PC commands and Sample software) × 1, Startup guide× 1, Operating precautions× 1 |
OPTIONS
Probe and Test fixtures (15)
When using the 9268-10 or 9269-10, external constant-voltage and constant-current sources are required.
SMD TEST FIXTURE IM9100
• Direct-connection testing
• Test SMDs with electrodes on the bottom
• DC to 8MHz£¨Can be measured up to 10 MHz, when combined with the special order model IM3536-01£©
• Measurable sample sizes: Metric (Inch): 0402 (01005), 0603 (0201), 1005 (0402)
SMD TEST FIXTURE IM9110
• For direct connection two-wire testing
• DC to 1 MHz
• Measurable sample size: 008004 (inch)
CONTACT TIPS IM9901
To replace the tip on the L2001, regular size, bundled with the L2001
CONTACT TIPS IM9902
To replace the tip on the L2001, small size
4-TERMINAL PROBE L2000
Cable length 1 m (3.28 ft), DC to 8 MHz£¨Can be measured up to 10 MHz, when combined with the special order model IM3536-01£©, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 5 mm (0.20 in)
PINCHER PROBE L2001
• DC to 8MHz, 50Ω termination
• Tip electrode spacing: 0.3 to 6 mm
• Measurable sample sizes: 0201 to 2220 (inch)
4-TERMINAL PROBE 9140-10
Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 5 mm (0.20 in)
TEST FIXTURE 9261-10
Cable length 1 m (3.28 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 (0.01 in) to 1.5 mm (0.06 in)
TEST FIXTURE 9262
Direct connection type, DC to 8 MHz£¨Can be measured up to 10 MHz, when combined with the special order model IM3536-01£©, measurable conductor diameter: ø0.3 (0.01 in) to 2 mm (0.08 in)
SMD TEST FIXTURE 9263
Direct connection type, DC to 8 MHz£¨Can be measured up to 10 MHz, when combined with the special order model IM3536-01£©, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.39 in)
DC BIAS VOLTAGE UNIT 9268-10
Direct connection type, 40 Hz to 8 MHz, maximum applied voltage of DC ±40 V
DC BIAS CURRENT UNIT 9269-10
Direct connection type, 40 Hz to 2 MHz, maximum applied current of DC 2 A
4-TERMINAL PROBE 9500-10
Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, measurable conductor diameter: φ0.3 mm (0.01 in) to 2 mm (0.08 in)
SMD TEST FIXTURE 9677
Direct connection type, For measuring SMDs with electrodes on the side; DC to 120 MHz, test sample dimensions: 3.5 mm ±0.5 mm (0.14 in ±0.02 in)
SMD TEST FIXTURE 9699
Direct connection type, For measuring SMDs with electrodes on the bottom; DC to 120 MHz, test sample dimensions: 1.0 mm (0.04 in) to 4.0 mm (0.16 in) wide, max. 1.5 mm (0.06 in) high