Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
Marktest Technology Sdn Bhd
Marktest Technology Sdn Bhd 202201041293 (1486990-K) (1486990-K)
Waktu
Pejabat
Isnin - Jumaat 8:30 AM - 5:30 PM
Sabtu - Ahad Closed
Open Closed
SSM
PENGUNJUNG

22-Jun-2024

Sonel MZC-306 Fault Loop Impedance Meter
INDEX CAT. WMGBMZC306
EAN 5907624021273

Ingress protection: IP 54
Measurement category: CAT III 1000 V, CAT IV 600 V
Data transmission: USB
Display: monochrome, backlit, segmented
 

Description
 

Lightweight and professional fault loop meter

Owing to a wide range of operating voltages, the professional meter Sonel MZC-306 enables measurements in various types of networks. The device is invaluable for a variety of electrical work in low-voltage areas, such as homes and buildings, public facilities, small workshops and small factories.

The resolution of the measurement result is 0.01 Ω - also when performing measurements in networks protected by RCD circuit breakers. The casing of the MZC-306 meter is made in IP54 protection degree, which ensures its resistance to mechanical damage. The cover of the device can be set in several positions, which enables easy and comfortable transport and use of the device.

Capabilities

  • Fault loop impedance measurement with 0.01!& resolution
  • Low-current impedance measurement in circuits protected by RCD ≥ 30mA with 0.01 !& resolution (100…440 V)
  • Operates in networks with voltages 110/190 V, 115/200 V, 127/220 V, 220/380 V, 230/400 V, 240/415 V, 290/500 V and 400/690 V (operating range 100…750 V)
  • Operating frequency 45…65 Hz
  • Calculation of fault current
  • Automatic differentiation between phase and phase-to-phase voltage
  • Possibility of applying 1.2, 5, 10, 20 m test leads or an adapter terminated by a power network plug
  • Measurement with swapped L and N conductors
  • Measurement of resistance (RS) and reactance (XS) components

Additionally features

  • Contact electrode - quick testing of proper connection of PE conductor.
  • Voltage measurement 0...750 V AC (0...250 V with resolution of 0,1 V).
  • Memory of 990 measurement results, ability to transfer the data to a PC via USB.
  • Power supply: batteries (4 x LR14) or rechargeable batteries.

Application

This instrument is irreplaceable for all kind of electrical works, especially in situations where there is a need to check the circuits under voltage of 400/690 V. The meter is used for tests in homes, apartment blocks, public buildings, small workshops or factories and even at wind farms.

The meter is a perfect tool for testing systems, where fault currents may reach 5.3 kA (measured according to EN 61557).
 



Technical data
 
Measurement functions Measurement range Display range Resolution Accuracy
Voltage 0 V…750 V 0 V…750 V from 0.1 V from ±(2% m.v. + 2 digits)
Short-circuit loop parameters        
2p method - standard current measurement maximum current 36.7 A from 0.13 Ω…1999 Ω acc. to EN 61557 0,00 Ω…1999 Ω from 0.01 Ω from ±(4% m.v. + 3 digits)
2p method - measurements without tripping RCDs from 0.43 Ω…1999 Ω acc. to EN 61557 0,00 Ω…1999 Ω from 0.01 Ω from ±(6% m.v. + 5 digits)
Short-circuit current readings        
2p method - standard current measurement Calculated on the basis of test Zs ranges and rated voltages 0.055 A…69.0 kA from 0.001 A Calculated on the basis of error for fault loop
2p method - measurements without tripping RCDs Calculated on the basis of test Zranges and rated voltages 0.055 A…40.0 kA from 0.001 A Calculated on the basis of error for fault loop

m.v. - measured value

 

Parameter Value
Net weight (kg) 1.3
Package weight (kg) 3.9
Package width (cm) 32
Package height (cm) 19
Package length (cm) 50
Hantar mesej anda ke Marktest Technology Sdn Bhd
Terima kasih untuk pertanyaan anda!
Perkhidmatan pelanggan kami akan menghubungi anda tidak lama lagi.
Nama Anda *
Nama Syarikat Anda
Emel Anda *
Nombor Telefon Anda *
Tajuk *
Mesej *
Captcha *
Pejabat Utama

Marktest Technology Sdn Bhd 202201041293 (1486990-K) (1486990-K)
19 (1st Floor), Jalan Sutera 1/6, Taman Sungai Abong Sutera, 84000 Muar, Johor, Malaysia.

Tel:

Emel:
Laman Web: https://www.marktest.com.my
Laman Web: https://marktest.newpages.com.my/
Laman Web: https://marktest.onesync.my/

Melayari Melalui : Laman Utama - Klasifikasi - Syarikat - Tempat - Tag - Produk - Berita Baru dan Promosi - Jawatan Kosong - Laman Web Mudah Alih - Google - Keputusan SEO

NEWPAGES

  • US 8142
  • GB 6710
  • CA 6119
  • AU 5621
  • IE 4310
  • BR 2252
  • NZ 1211
  • SG 543
Orang dalam talian
Seni Jaya Logo
Brochure
Download
Our PackageContact Us