DC Fast Charging for Public, Commercial and Fleet EV Charging
50kW modular DC fast charger with CCS, CHAdeMO and optional AC Type 2 charging configurations.
Circontrol Raption 50 is a DC fast charging station designed for locations where EVs need to continue their journey quickly, including public charging areas, shopping centres, airports, roadside rest areas, business parks, fleet depots and taxi charging points.
Its modular power architecture is designed to improve uptime. If one power module fails, the remaining modules can continue charging, helping Charge Point Operators reduce downtime and service impact.
Raption 50 is suitable for charge point operators, commercial property owners, fleet operators and infrastructure projects that need a robust, connected and serviceable fast charging solution.
Application
Raption 50 is designed for both public access and private charging environments. It is suitable for urban spaces, shopping centres, airports, roadside rest areas, offices, industrial sites, company EV fleets, taxi charging stations and fleet depots.
The charger is intended for locations where charging time, user experience, charger uptime and serviceability are important.
Designed for Charge Point Operators and EV Users
Modular Power Technology
Power modules are arranged to improve uptime. If one module fails, remaining modules can continue charging.
High Efficiency Operation
Power modules can be disconnected when lower charging power is requested, helping reduce energy consumption and operating cost.
Power Scalability
The modular architecture allows configurations such as 25kW and 50kW DC output to meet present and future demand.
Connector Care Design
Optional gun locking and cable floating design help reduce cable damage risk and improve charger availability.
Easy Service Access
Double frontal key-locked door design allows easier access for installation and preventive or corrective service.
User-Friendly HMI
8" anti-vandal daylight-readable touchscreen provides instructions, plug status and multi-language support.
Product Highlights
For Charge Point Owners / Operators
- High uptime through modular power technology
- Lower operating cost through sustained high efficiency
- Power scalability from 25kW to 50kW configuration
- Connector care concept to reduce cable damage risk
- Front service access for easier maintenance
- Slim, robust and professional external design
For EV Users
- 8" anti-vandal touchscreen interface
- Clear charging instructions and plug status display
- Multi-language interface support
- Built-in courtesy light for dark areas
- Accessible connector and display height design
- RGB status indication for local visibility
Supply, Installation, Testing and Commissioning
DC fast charger installation requires more detailed electrical and civil coordination than a standard AC EV charger. Proper incoming supply capacity, protection, earthing, communication, network integration and commissioning are important before handover.
Site Capacity Review
Review incoming supply capacity, transformer capacity, feeder, protection and required power supply capacity.
Civil and Parking Layout
Confirm charger location, plinth, cable route, bollards, vehicle access, connector reach and user access requirements.
Electrical Installation
Install incoming feeder, protection, earthing, communication link and charger supply based on approved design.
Communication Setup
Configure Ethernet or optional wireless communication and connect to compatible backend platform where required.
Commissioning
Verify charger operation, connector status, HMI, RFID, power output, protection and network communication.
Operator Training
Provide guidance on charger operation, emergency response, user flow, basic troubleshooting and maintenance points.
Suitable Applications
Public Charging Stations
Suitable for public EV charging networks and charge point operator deployments.
Shopping Centres
Provide fast EV charging facilities for customers and visitors.
Roadside Rest Areas
Support longer-distance EV travel with faster charging stops.
Fleet Depots
Suitable for EV fleet operators that need faster turnaround charging.
Hotels and Hospitality
Provide premium EV charging for guests and visitors.
Industrial and Business Parks
Suitable for company EVs, visitors, delivery fleets and shared commercial charging.
General Specifications
| Electrical / Compliance Item | Specification |
|---|---|
| AC Power Supply | 3P + N + PE |
| AC Voltage | 400V AC ±10% |
| Power Factor | >0.98 |
| Efficiency | 95% at nominal output power |
| Frequency | 50 / 60Hz |
| Electrical Input Protection | Main breaker disconnection |
| Overcurrent Protection | MCB |
| Safety Protection | RCD 30mA Type A |
| Network Connection | Ethernet 10 / 100BaseTX |
| Interface Protocol | OCPP 1.5, OCPP 1.6J optional |
| Compliance | CE / Combo-2, DIN 70121, ISO15118, EN61851-1, EN61851-23, CHAdeMO certified |
| Mechanical / Operating Item | Specification |
|---|---|
| Enclosure Rating | IP54 / IK10 |
| Enclosure Material | Stainless steel |
| Operating Temperature | -30°C to +50°C |
| Storage Temperature | -40°C to +60°C |
| Operating Humidity | 5% to 95%, non-condensing |
| RFID System | ISO / IEC14443A/B, MIFARE Classic / DESFire EV1, ISO 18092 / ECMA-340, NFC 13.56MHz |
| Display HMI | 8" anti-vandal touchscreen |
| Dimensions | 310 x 940 x 1800mm, without cable engaged |
| Weight | 235kg |
| Cooling System | Air cooling fans |
| Operational Noise Level | <55dBA |
Connector, Metering and Optional Devices
| Connector / Metering Item | Specification |
|---|---|
| Power Limit Control | DC and AC by software |
| DC Cable Length CCS | 3m |
| DC Cable Length CHAdeMO | 3m |
| AC Cable Length | 3m |
| Status Indication | RGB colour indicator |
| AC Meter | Complies with EN 50470 MID European standards or IEC 62052-11 |
| Optional Devices | Specification |
|---|---|
| Wireless Communication | 4G LTE / WiFi Hotspot / GPRS / GSM |
| Surge Protection | Four pole transient surge protector, IEC 61643-1 Class II |
| Safety Protection | RCD Type B |
| Cable Length | 5.5m, all cables |
| Anti-Vandal Connector Protection | CHAdeMO / CCS mechanical connector locking |
| 25kW DC Version | Power output DC 25kW, 2 x 12.5kW modules |
Model Specifications
| Models | CCS CHA T2C63 | CCS CHA T2S32 | CCS CHA | CCS T2S32 |
|---|---|---|---|---|
| Maximum AC Input Current | 138A / 101A for 25kW version | 108A / 70A for 25kW version | 76A / 38A for 25kW version | 108A / 70A for 25kW version |
| Required Power Supply Capacity | 96kVA / 70kVA for 25kW version | 75kVA / 48kVA for 25kW version | 53kVA / 26kVA for 25kW version | 75kVA / 48kVA for 25kW version |
| Maximum Output Power | DC 50kW / 25kW at 400VDC; AC 43kW | DC 50kW / 25kW at 400VDC; AC 22kW | DC 50kW / 25kW at 400VDC | DC 50kW / 25kW at 400VDC; AC 22kW |
| Output Voltage Range | DC 50–500V; AC 400V | DC 50–500V; AC 400V | DC 50–500V | DC 50–500V; AC 400V |
| Maximum Output Current | DC 125A / 63A for 25kW version; AC 63A | DC 125A / 63A for 25kW version; AC 32A | DC 125A / 63A for 25kW version | DC 125A / 63A for 25kW version; AC 32A |
| Number of Plugs | 3 | 3 | 2 | 2 |
| Connection | CCS 2, JEVS G105, Type 2 tethered cable | CCS 2, JEVS G105, Type 2 socket with lock system | CCS 2, JEVS G105 | CCS 2, Type 2 socket with lock system |
Additional Model Configurations
| Models | CHA T2S32 | CCS | CHA |
|---|---|---|---|
| Maximum AC Input Current | 108A / 70A for 25kW version | 76A / 38A for 25kW version | 76A / 38A for 25kW version |
| Required Power Supply Capacity | 75kVA / 48kVA for 25kW version | 53kVA / 26kVA for 25kW version | 53kVA / 26kVA for 25kW version |
| Maximum Output Power | DC 50kW / 25kW at 400VDC; AC 22kW | DC 50kW / 25kW at 400VDC | DC 50kW / 25kW at 400VDC |
| Output Voltage Range | DC 50–500V; AC 400V | DC 50–500V | DC 50–500V |
| Maximum Output Current | DC 125A / 63A for 25kW version; AC 32A | DC 125A / 63A for 25kW version | DC 125A / 63A for 25kW version |
| Number of Plugs | 2 | 1 | 1 |
| Connection | JEVS G105, Type 2 socket with lock system | CCS 2 | JEVS G105 |
Product Summary
Circontrol Raption 50 is a robust DC fast charging station for public, commercial and fleet EV charging applications.
With modular power technology, 50kW DC charging, optional 25kW version, CCS / CHAdeMO / AC Type 2 configurations, OCPP communication, RFID / NFC access, 8" anti-vandal touchscreen, IP54 / IK10 enclosure, stainless steel construction and operator-friendly service access, Raption 50 is suitable for EV charging networks, commercial car parks, hotels, roadside sites, fleet depots and business parks.
Contact us for model selection, site assessment, electrical capacity review, installation planning and commissioning support.