Please login to use this feature. You can use this feature to add the product to your favourite list.
Close
You have added this product to your favorite list. Check My Favourite
Close
You have removed this product from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your favourites list.
Close
This company has been added successfully. Check My Favourite
Close
This company has been removed from your favourite list.
Close
Please login to use this feature. You can use this feature to add the company to your inquiry cart.
Close
This company has been added to your inquiry cart.
Close
This company has been removed from your inquiry cart.
Close
This product has been added to your inquiry cart.
Close
This product has been removed from your inquiry cart.
Close
Maximum number of Product/Company has been reached in inquiry cart.
Close
LUX & BRILLIANCE TECHNOLOGIES SDN. BHD.
LUX & BRILLIANCE TECHNOLOGIES SDN. BHD. 201601032161 (1203102-K)
Waktu
Pejabat
Isnin - Jumaat 9:00 AM - 5:30 PM
Sabtu - Ahad Closed
We′re closed on Public Holiday
Open Closed
Onesync AI SSM
PENGUNJUNG
Media Sosial Link
  • facebook

Penang,Selangor,Kuala Lumpur (KL),Butterworth,Jalan Kuchai Lama - High Accuracy Bench-top Spectrophotometer LBS-826

13-Sep-2023

High Accuracy Bench-top Spectrophotometer LBS-826 High Accuracy Bench-top Spectrophotometer LBS-826

Tags:
-
Produk Dilihat 1039
LBS-826 is a bench-top spectrophotometer with high accuracy and excellent repeatability. It is with advanced process technology and powerful data processor which guarantee its good performance on measuring black samples. Auto calibration guarantees its long term repeatability. Improved light source for good performance when measure fluorescence and normal samples. Test result is with good consistency with Europe, US and Japan Brand.

360nm-780nm Wavelength Dual Light Path Sensor Array High Accuracy Benchtop Spectrophotometer For Textile Color Matching 0

Part 1. Instrument Advantage
1. Automatic calibration;
2. High stability UV light source, providing stable fluorescence measurement result;
3. Excellent repeatability when measuring on black samples;
4. Excellent consistency with other competing products made in United States, Japan, and Europe;
5. Excellent long-term repeatability, even after rapid changes in the environment can still guarantee excellent repeatability
6. It has two lamps: pulsed xenon and LED
7. 24 kinds of illuminants and more than 40 measurement indices
8. Temperature and humidity compensation function
9. Seven-inch touch screen, Android operate system
10. Dual optical paths spectrum analysis technology
11. Support SCI+SCE simultaneous rapid measurement
 

Instrument adopts D/8 geometry which is highly recommends by CIE (International Commission on Illumination) to meet color measurement of different industries. It supports both SCI (specula component included) and SCE (specular component excluded) mode for better detect of color change. Fast SCI+SCE measurement, test time only need less than 4s.

 

360nm-780nm Wavelength Dual Light Path Sensor Array High Accuracy Benchtop Spectrophotometer For Textile Color Matching 1

 

9. Rotatable Touch Screen with Android Operate System

Screen position and direction can be adjusted according to the instrument test methods.

 

 

10. Open Transmittance Measurement Area, no limit on sample size

11. Different Kinds of Accessories for simple measurement

It contains 15 kinds of standard and 12 kinds of optional accessories to measure different kinds of materials

 

360nm-780nm Wavelength Dual Light Path Sensor Array High Accuracy Benchtop Spectrophotometer For Textile Color Matching 4

 

12. Accessory Drawer to Protect and Store Accessories

13. Switchable Reflectance Apertures (30mm,18mm,11mm and 6mm)

 

360nm-780nm Wavelength Dual Light Path Sensor Array High Accuracy Benchtop Spectrophotometer For Textile Color Matching 6

 

14. Four Kinds of UV Test Modes for Fluorescence Material Measurement

 

360nm-780nm Wavelength Dual Light Path Sensor Array High Accuracy Benchtop Spectrophotometer For Textile Color Matching 7

 

Part 4. Bench-top Spectrophotometer Structure

 

360nm-780nm Wavelength Dual Light Path Sensor Array High Accuracy Benchtop Spectrophotometer For Textile Color Matching 8

360nm-780nm Wavelength Dual Light Path Sensor Array High Accuracy Benchtop Spectrophotometer For Textile Color Matching 9




Part 2. Technical Data
Model High Accuracy Bench-top Spectrophotometer LBS-826
Illumination/ Viewing System Reflectance: d/8(Diffused illumination, 8 degree viewing)
Simultaneous measurement of SCI/SCE, conform to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, DIN5033 Teil7, JIS Z8722 condition C, ASTM E1164,ASTM-D1003-07
Transmittance d/0(Diffused illumination, 0 degree viewing )
Sensor Silicon Photodiode Array
Grating Method Concave Grating
Sphere Diameter 152mm
Wavelength Range 360-780nm
Wavelength Pitch 10nm
Half Band Width 5nm
Reflectance Range
Resolution
0-200%
0.01%
Light Source Pulse Xenon Lamp and LED
UV Measurement Include UV, 400nm cut, 420nm cut, 460nm cut
Measurement Time SCI/SCE < 2s
SCI+SCE < 4s
Measurement Aperture Reflectance: XLAV Φ30mm, LAV 18mm,MAV Φ11mm,SAV Φ6mm
Transmittance:Φ25mm
(Auto aperture size recognition)
Transmittance Sample Size No limit on sample width and height, thickness ≤50mm
Long Term Repeatability XLAV Chromaticity value: Standard deviation within ΔE*ab 0.01 (20¡æ±10¡æ arbitrary temperature change, white tile is measured every hour within 24 hours£©
Repeatability XLAV Spectrum Reflectance/Transmittance: standard deviation within 0.1%
XLAV Chromaticity value: Standard deviation within ΔE*ab 0.01 (max 0.02) * When a white tile is measured 30 x at 10-second intervals after white calibration
Inter-Instrument Agreement XLAV ΔE*ab 0.1 (BCRA Series II, Average measurement of 12 tiles, at 23¡æ)
Observer 2° and 10°
Illuminants A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,DLF,NBF,TL83,TL84
Language English, Russian, Spanish, Portuguese, Japanese, Thai, Korean, German, French, Polish, Chinese (simple and traditional),
Display Reflectance and Transmittance graph/value, color value, color difference values, pass/fail, color simulation, color assessment, haze, liquid chromaticity values, color tendency
Color Spaces L*a*b, L*C*h, Hunter Lab, Yxy, XYZ
Other Indices WI(ASTM E313-00,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Stensby)
YI(ASTM D1925,ASTM E313-00,ASTM E313-73),Tint(ASTM E313-00),Metamerism index milm, stain fastness, color fastness, ISO brightness, R457, A density, T density, E density, M Density, APHA/Pt-Co/Hazen, Gardner, Saybolt, ASTM color, Haze, Total Transmittance, Opacity, Color Strength
Color Difference ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00, ΔE*ab(hunter),555 shade sort
Storage Memory 8GB
Screen Size 7 Inches Touch Screen
Operate System Android
Power Adaptor 12V/3A
Operate Temperature 5-40¡æ(40-104F), relative humidity 80% (at 35¡æ) no condensation
Storage Temperature -20-45¡æ(-4-113F), relative humidity 80% (at 35¡æ) no condensation
Accessories Power Adaptor, USB Cable, fixture for transmittance, U disk (PC software), Black Calibration Cavity, White and Green Calibration Tile, Reflectance Test Support,30mm,18mm,11mm and 6mm apertures, reflectance sample
fixture, Glass Cell 40x10mm,reflectance fixture
Optional Accessories Heating Fixture for Transmittance, Vertical Support and Pneumatic ram for downward measurement, Reflectance fixture for small size sample, Reflectance Glass Cell Support, Corrosion-Resistant Protective Plate (non-removable), Sample Holder for Fiber, Film Fixture, Transmittance Fixture for Small Aperture, Trolley Case, European Standard Plug, American Standard Plug
Interface RS-232,USB,USB-B
Other Function 1. Camera to view measurement area;
2. Support horizontal, vertical and downward measurement method (need optional accessories to support for downward measurement);
3. Auto humidity and temperature compensation function.

Part 3. Warranty
Instrument warranty is one year for whole instrument.

 

 

Hantar mesej anda ke LUX & BRILLIANCE TECHNOLOGIES SDN. BHD.
Terima kasih untuk pertanyaan anda!
Perkhidmatan pelanggan kami akan menghubungi anda tidak lama lagi.
Nama Anda *
Nama Syarikat Anda
Emel Anda *
Nombor Telefon Anda *
Tajuk *
Mesej *
Captcha *
Pejabat Utama

LUX & BRILLIANCE TECHNOLOGIES SDN. BHD. 201601032161 (1203102-K)
7442, Jalan Bagan Lalang, Taman Carissa Villa, 13400 Butterworth, Penang, Malaysia.

Tel:
Fax:

Emel:
Laman Web: https://www.lnbtec.com
Laman Web: https://lnbtec.newpages.com.my/
Laman Web: https://lnbtec.onesync.my/

Pejabat Lain

KL Office
Jalan Kuchai Lama, Kuala Lumpur, Malaysia.

Tel:
H/p:
Emel:

Melayari Melalui : Laman Utama - Klasifikasi - Syarikat - Tempat - Tag - Produk - Berita Baru dan Promosi - Jawatan Kosong - Laman Web Mudah Alih - Google - Keputusan SEO

NEWPAGES

Seni Jaya Logo
Brochure
Download
Our PackageContact Us